Cargando…
Reduction of Collimator Correction Artefacts with Bayesian Reconstruction in Spect
Poor resolution of single photon emission computed tomography (SPECT) has degraded its use in clinical practice. Collimator correction has been shown to improve the reconstructed resolution, but the correction can generate ringing artefacts, which lower image quality. This paper investigates whether...
Autores principales: | , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3065867/ https://www.ncbi.nlm.nih.gov/pubmed/21490730 http://dx.doi.org/10.1155/2011/630813 |
_version_ | 1782201030097764352 |
---|---|
author | Kangasmaa, Tuija Sohlberg, Antti Kuikka, Jyrki T. |
author_facet | Kangasmaa, Tuija Sohlberg, Antti Kuikka, Jyrki T. |
author_sort | Kangasmaa, Tuija |
collection | PubMed |
description | Poor resolution of single photon emission computed tomography (SPECT) has degraded its use in clinical practice. Collimator correction has been shown to improve the reconstructed resolution, but the correction can generate ringing artefacts, which lower image quality. This paper investigates whether Bayesian reconstruction methods could reduce these artefacts. We have applied and tested three Bayesian reconstruction methods: smoothing prior, median root prior, and anatomical prior. To demonstrate the efficacy of these methods, we compared their physical and visual performance both in phantom and patient studies. All the three Bayesian reconstruction methods reduced the collimator correction artefacts. Images reconstructed using the smoothing prior and the median root prior had slightly lower contrast than the standard reconstruction with collimator correction, whereas the anatomical prior produced images with good resolution and contrast. |
format | Text |
id | pubmed-3065867 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-30658672011-04-13 Reduction of Collimator Correction Artefacts with Bayesian Reconstruction in Spect Kangasmaa, Tuija Sohlberg, Antti Kuikka, Jyrki T. Int J Mol Imaging Research Article Poor resolution of single photon emission computed tomography (SPECT) has degraded its use in clinical practice. Collimator correction has been shown to improve the reconstructed resolution, but the correction can generate ringing artefacts, which lower image quality. This paper investigates whether Bayesian reconstruction methods could reduce these artefacts. We have applied and tested three Bayesian reconstruction methods: smoothing prior, median root prior, and anatomical prior. To demonstrate the efficacy of these methods, we compared their physical and visual performance both in phantom and patient studies. All the three Bayesian reconstruction methods reduced the collimator correction artefacts. Images reconstructed using the smoothing prior and the median root prior had slightly lower contrast than the standard reconstruction with collimator correction, whereas the anatomical prior produced images with good resolution and contrast. Hindawi Publishing Corporation 2011 2010-12-01 /pmc/articles/PMC3065867/ /pubmed/21490730 http://dx.doi.org/10.1155/2011/630813 Text en Copyright © 2011 Tuija Kangasmaa et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Kangasmaa, Tuija Sohlberg, Antti Kuikka, Jyrki T. Reduction of Collimator Correction Artefacts with Bayesian Reconstruction in Spect |
title | Reduction of Collimator Correction Artefacts with Bayesian Reconstruction in Spect |
title_full | Reduction of Collimator Correction Artefacts with Bayesian Reconstruction in Spect |
title_fullStr | Reduction of Collimator Correction Artefacts with Bayesian Reconstruction in Spect |
title_full_unstemmed | Reduction of Collimator Correction Artefacts with Bayesian Reconstruction in Spect |
title_short | Reduction of Collimator Correction Artefacts with Bayesian Reconstruction in Spect |
title_sort | reduction of collimator correction artefacts with bayesian reconstruction in spect |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3065867/ https://www.ncbi.nlm.nih.gov/pubmed/21490730 http://dx.doi.org/10.1155/2011/630813 |
work_keys_str_mv | AT kangasmaatuija reductionofcollimatorcorrectionartefactswithbayesianreconstructioninspect AT sohlbergantti reductionofcollimatorcorrectionartefactswithbayesianreconstructioninspect AT kuikkajyrkit reductionofcollimatorcorrectionartefactswithbayesianreconstructioninspect |