Cargando…

Reduction of Collimator Correction Artefacts with Bayesian Reconstruction in Spect

Poor resolution of single photon emission computed tomography (SPECT) has degraded its use in clinical practice. Collimator correction has been shown to improve the reconstructed resolution, but the correction can generate ringing artefacts, which lower image quality. This paper investigates whether...

Descripción completa

Detalles Bibliográficos
Autores principales: Kangasmaa, Tuija, Sohlberg, Antti, Kuikka, Jyrki T.
Formato: Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3065867/
https://www.ncbi.nlm.nih.gov/pubmed/21490730
http://dx.doi.org/10.1155/2011/630813
_version_ 1782201030097764352
author Kangasmaa, Tuija
Sohlberg, Antti
Kuikka, Jyrki T.
author_facet Kangasmaa, Tuija
Sohlberg, Antti
Kuikka, Jyrki T.
author_sort Kangasmaa, Tuija
collection PubMed
description Poor resolution of single photon emission computed tomography (SPECT) has degraded its use in clinical practice. Collimator correction has been shown to improve the reconstructed resolution, but the correction can generate ringing artefacts, which lower image quality. This paper investigates whether Bayesian reconstruction methods could reduce these artefacts. We have applied and tested three Bayesian reconstruction methods: smoothing prior, median root prior, and anatomical prior. To demonstrate the efficacy of these methods, we compared their physical and visual performance both in phantom and patient studies. All the three Bayesian reconstruction methods reduced the collimator correction artefacts. Images reconstructed using the smoothing prior and the median root prior had slightly lower contrast than the standard reconstruction with collimator correction, whereas the anatomical prior produced images with good resolution and contrast.
format Text
id pubmed-3065867
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-30658672011-04-13 Reduction of Collimator Correction Artefacts with Bayesian Reconstruction in Spect Kangasmaa, Tuija Sohlberg, Antti Kuikka, Jyrki T. Int J Mol Imaging Research Article Poor resolution of single photon emission computed tomography (SPECT) has degraded its use in clinical practice. Collimator correction has been shown to improve the reconstructed resolution, but the correction can generate ringing artefacts, which lower image quality. This paper investigates whether Bayesian reconstruction methods could reduce these artefacts. We have applied and tested three Bayesian reconstruction methods: smoothing prior, median root prior, and anatomical prior. To demonstrate the efficacy of these methods, we compared their physical and visual performance both in phantom and patient studies. All the three Bayesian reconstruction methods reduced the collimator correction artefacts. Images reconstructed using the smoothing prior and the median root prior had slightly lower contrast than the standard reconstruction with collimator correction, whereas the anatomical prior produced images with good resolution and contrast. Hindawi Publishing Corporation 2011 2010-12-01 /pmc/articles/PMC3065867/ /pubmed/21490730 http://dx.doi.org/10.1155/2011/630813 Text en Copyright © 2011 Tuija Kangasmaa et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Kangasmaa, Tuija
Sohlberg, Antti
Kuikka, Jyrki T.
Reduction of Collimator Correction Artefacts with Bayesian Reconstruction in Spect
title Reduction of Collimator Correction Artefacts with Bayesian Reconstruction in Spect
title_full Reduction of Collimator Correction Artefacts with Bayesian Reconstruction in Spect
title_fullStr Reduction of Collimator Correction Artefacts with Bayesian Reconstruction in Spect
title_full_unstemmed Reduction of Collimator Correction Artefacts with Bayesian Reconstruction in Spect
title_short Reduction of Collimator Correction Artefacts with Bayesian Reconstruction in Spect
title_sort reduction of collimator correction artefacts with bayesian reconstruction in spect
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3065867/
https://www.ncbi.nlm.nih.gov/pubmed/21490730
http://dx.doi.org/10.1155/2011/630813
work_keys_str_mv AT kangasmaatuija reductionofcollimatorcorrectionartefactswithbayesianreconstructioninspect
AT sohlbergantti reductionofcollimatorcorrectionartefactswithbayesianreconstructioninspect
AT kuikkajyrkit reductionofcollimatorcorrectionartefactswithbayesianreconstructioninspect