Performance of an implantable automatic atrial fibrillation detection device: impact of software adjustments and relevance of manual episode analysis

AIMS: Implantable loop recorders (ILRs) with specific atrial fibrillation (AF) detection algorithms (ILR-AF) have been developed for continuous AF monitoring. We sought to analyse the clinical value of a new AF monitoring device and to compare it to serial 7-day Holter. METHODS AND RESULTS: Sixty-fo...

Descripción completa

Detalles Bibliográficos
Autores principales: Eitel, Charlotte, Husser, Daniela, Hindricks, Gerhard, Frühauf, Manuela, Hilbert, Sebastian, Arya, Arash, Gaspar, Thomas, Wetzel, Ulrike, Bollmann, Andreas, Piorkowski, Christopher
Formato: Texto
Lenguaje:English
Publicado: Oxford University Press 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3065917/
https://www.ncbi.nlm.nih.gov/pubmed/21325346
http://dx.doi.org/10.1093/europace/euq511
Descripción
Sumario:AIMS: Implantable loop recorders (ILRs) with specific atrial fibrillation (AF) detection algorithms (ILR-AF) have been developed for continuous AF monitoring. We sought to analyse the clinical value of a new AF monitoring device and to compare it to serial 7-day Holter. METHODS AND RESULTS: Sixty-four consecutive patients suffering from paroxysmal AF were included in this prospective analysis and received an ILR-AF. Manual electrogram analysis was performed for each automatically detected episode and each was categorized into one of three possible diagnoses: ‘no AF', ‘definite AF', and ‘possible AF' (non-diagnostic). Analysis was performed separately before and after a software upgrade that was introduced during the course of the study. A subgroup of patients (51 of 64) underwent AF catheter ablation with subsequent serial 7-day Holter in comparison with the ILR-AF. A total of 333 interrogations were performed (203 before and 130 after software upgrade). The number of patients with AF misdetection was significantly reduced from 72 to 44% following the software upgrade (P= 0.001). The number of patients with non-diagnostic interrogations went from 38 to 16% (P= 0.001). Compared with serial 7-day Holter, the ILR-AF had a tendency to detect a higher number of patients with AF recurrences (31 vs. 24%; P = 0.125). CONCLUSIONS: The rate of AF detection on ILR-AF may be higher compared with standard AF monitoring. However, false-positive AF recordings hamper the clinical value. Developements in device technology and device handling are necessary to minimize non-diagnostic interrogations.