Cargando…

Analysis of impulse oscillometric measures of lung function and respiratory system model parameters in small airway-impaired and healthy children over a 2-year period

BACKGROUND: Is Impulse Oscillometry System (IOS) a valuable tool to measure respiratory system function in Children? Asthma (A) is the most prevalent chronic respiratory disease in children. Therefore, early and accurate assessment of respiratory function is of tremendous clinical interest in diagno...

Descripción completa

Detalles Bibliográficos
Autores principales: Meraz, Erika G, Nazeran, Homer, Ramos, Carlos D, Nava, Pat, Diong, Bill, Goldman, Michael D
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3071336/
https://www.ncbi.nlm.nih.gov/pubmed/21439045
http://dx.doi.org/10.1186/1475-925X-10-21
_version_ 1782201439322374144
author Meraz, Erika G
Nazeran, Homer
Ramos, Carlos D
Nava, Pat
Diong, Bill
Goldman, Michael D
author_facet Meraz, Erika G
Nazeran, Homer
Ramos, Carlos D
Nava, Pat
Diong, Bill
Goldman, Michael D
author_sort Meraz, Erika G
collection PubMed
description BACKGROUND: Is Impulse Oscillometry System (IOS) a valuable tool to measure respiratory system function in Children? Asthma (A) is the most prevalent chronic respiratory disease in children. Therefore, early and accurate assessment of respiratory function is of tremendous clinical interest in diagnosis, monitoring and treatment of respiratory conditions in this subpopulation. IOS has been successfully used to measure lung function in children with a high degree of sensitivity and specificity to small airway impairments (SAI) and asthma. IOS measures of airway function and equivalent electrical circuit models of the human respiratory system have been developed to quantify the severity of these conditions. Previously, we have evaluated several known respiratory models based on the Mead's model and more parsimonious versions based on fitting IOS data known as extended RIC (eRIC) and augmented RIC (aRIC) models have emerged, which offer advantages over earlier models. METHODS: IOS data from twenty-six children were collected and compared during pre-bronchodilation (pre-B) and post- bronchodilation (post-B) conditions over a period of 2 years. RESULTS AND DISCUSSION: Are the IOS and model parameters capable of differentiating between healthy children and children with respiratory system distress? Children were classified into two main categories: Healthy (H) and Small Airway-Impaired (SAI). The IOS measures and respiratory model parameters analyzed differed consistently between H and SAI children. SAI children showed smaller trend of "growth" and larger trend of bronchodilator responses than H children. The two model parameters: peripheral compliance (Cp) and peripheral resistance (Rp) tracked IOS indices of small airway function well. Cp was a more sensitive index than Rp. Both eRIC and aRIC Cps and the IOS Reactance Area, AX, (also known as the "Goldman Triangle") showed good correlations. CONCLUSIONS: What are the most useful IOS and model parameters? In this work we demonstrate that IOS parameters such as resistance at 5 Hz (R5), frequency-dependence of resistance (fdR: R5-R20), reactance area (AX), and parameter estimates of respiratory system such as Cp and Rp provide sensitive indicators of lung function and have the capacity to differentiate between obstructed and non-obstructed airway conditions. They are also capable of demonstrating airway growth-related changes over a two-year period. We conclude that the IOS parameters AX and the eRIC model derived parameter Cp are the most reliable parameters to track lung function in children before and after bronchodilator and over a time period (2 years). Which model is more suitable for interpreting IOS data? IOS data are equally well-modelled by eRIC and aRIC models, based on the close correlations of their corresponding parameters - excluding upper airway shunt compliance. The eRIC model is a more parsimonious and equally powerful model in capturing the differences in IOS indices between SAI and H children. Therefore, it may be considered a clinically-preferred model of lung function.
format Text
id pubmed-3071336
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-30713362011-04-06 Analysis of impulse oscillometric measures of lung function and respiratory system model parameters in small airway-impaired and healthy children over a 2-year period Meraz, Erika G Nazeran, Homer Ramos, Carlos D Nava, Pat Diong, Bill Goldman, Michael D Biomed Eng Online Research BACKGROUND: Is Impulse Oscillometry System (IOS) a valuable tool to measure respiratory system function in Children? Asthma (A) is the most prevalent chronic respiratory disease in children. Therefore, early and accurate assessment of respiratory function is of tremendous clinical interest in diagnosis, monitoring and treatment of respiratory conditions in this subpopulation. IOS has been successfully used to measure lung function in children with a high degree of sensitivity and specificity to small airway impairments (SAI) and asthma. IOS measures of airway function and equivalent electrical circuit models of the human respiratory system have been developed to quantify the severity of these conditions. Previously, we have evaluated several known respiratory models based on the Mead's model and more parsimonious versions based on fitting IOS data known as extended RIC (eRIC) and augmented RIC (aRIC) models have emerged, which offer advantages over earlier models. METHODS: IOS data from twenty-six children were collected and compared during pre-bronchodilation (pre-B) and post- bronchodilation (post-B) conditions over a period of 2 years. RESULTS AND DISCUSSION: Are the IOS and model parameters capable of differentiating between healthy children and children with respiratory system distress? Children were classified into two main categories: Healthy (H) and Small Airway-Impaired (SAI). The IOS measures and respiratory model parameters analyzed differed consistently between H and SAI children. SAI children showed smaller trend of "growth" and larger trend of bronchodilator responses than H children. The two model parameters: peripheral compliance (Cp) and peripheral resistance (Rp) tracked IOS indices of small airway function well. Cp was a more sensitive index than Rp. Both eRIC and aRIC Cps and the IOS Reactance Area, AX, (also known as the "Goldman Triangle") showed good correlations. CONCLUSIONS: What are the most useful IOS and model parameters? In this work we demonstrate that IOS parameters such as resistance at 5 Hz (R5), frequency-dependence of resistance (fdR: R5-R20), reactance area (AX), and parameter estimates of respiratory system such as Cp and Rp provide sensitive indicators of lung function and have the capacity to differentiate between obstructed and non-obstructed airway conditions. They are also capable of demonstrating airway growth-related changes over a two-year period. We conclude that the IOS parameters AX and the eRIC model derived parameter Cp are the most reliable parameters to track lung function in children before and after bronchodilator and over a time period (2 years). Which model is more suitable for interpreting IOS data? IOS data are equally well-modelled by eRIC and aRIC models, based on the close correlations of their corresponding parameters - excluding upper airway shunt compliance. The eRIC model is a more parsimonious and equally powerful model in capturing the differences in IOS indices between SAI and H children. Therefore, it may be considered a clinically-preferred model of lung function. BioMed Central 2011-03-25 /pmc/articles/PMC3071336/ /pubmed/21439045 http://dx.doi.org/10.1186/1475-925X-10-21 Text en Copyright ©2011 Meraz et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Meraz, Erika G
Nazeran, Homer
Ramos, Carlos D
Nava, Pat
Diong, Bill
Goldman, Michael D
Analysis of impulse oscillometric measures of lung function and respiratory system model parameters in small airway-impaired and healthy children over a 2-year period
title Analysis of impulse oscillometric measures of lung function and respiratory system model parameters in small airway-impaired and healthy children over a 2-year period
title_full Analysis of impulse oscillometric measures of lung function and respiratory system model parameters in small airway-impaired and healthy children over a 2-year period
title_fullStr Analysis of impulse oscillometric measures of lung function and respiratory system model parameters in small airway-impaired and healthy children over a 2-year period
title_full_unstemmed Analysis of impulse oscillometric measures of lung function and respiratory system model parameters in small airway-impaired and healthy children over a 2-year period
title_short Analysis of impulse oscillometric measures of lung function and respiratory system model parameters in small airway-impaired and healthy children over a 2-year period
title_sort analysis of impulse oscillometric measures of lung function and respiratory system model parameters in small airway-impaired and healthy children over a 2-year period
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3071336/
https://www.ncbi.nlm.nih.gov/pubmed/21439045
http://dx.doi.org/10.1186/1475-925X-10-21
work_keys_str_mv AT merazerikag analysisofimpulseoscillometricmeasuresoflungfunctionandrespiratorysystemmodelparametersinsmallairwayimpairedandhealthychildrenovera2yearperiod
AT nazeranhomer analysisofimpulseoscillometricmeasuresoflungfunctionandrespiratorysystemmodelparametersinsmallairwayimpairedandhealthychildrenovera2yearperiod
AT ramoscarlosd analysisofimpulseoscillometricmeasuresoflungfunctionandrespiratorysystemmodelparametersinsmallairwayimpairedandhealthychildrenovera2yearperiod
AT navapat analysisofimpulseoscillometricmeasuresoflungfunctionandrespiratorysystemmodelparametersinsmallairwayimpairedandhealthychildrenovera2yearperiod
AT diongbill analysisofimpulseoscillometricmeasuresoflungfunctionandrespiratorysystemmodelparametersinsmallairwayimpairedandhealthychildrenovera2yearperiod
AT goldmanmichaeld analysisofimpulseoscillometricmeasuresoflungfunctionandrespiratorysystemmodelparametersinsmallairwayimpairedandhealthychildrenovera2yearperiod