Cargando…

A Validated Reverse Phase HPLC Method for the Determination of Disodium EDTA in Meropenem Drug Substance with UV-Detection using Precolumn Derivatization Technique

This paper deals with development and validation of a high performance liquid chromatographic method for the quantitative determination of disodium EDTA (Ethylenediaminetetraacetic acid) in Meropenem active pharmaceutical ingredient (API). EDTA was derivatized with Ferric chloride solution by heatin...

Descripción completa

Detalles Bibliográficos
Autores principales: Narola, Bhavil, Singh, A.S., Mitra, M., Santhakumar, P.R., Chandrashekhar, T.G.
Formato: Texto
Lenguaje:English
Publicado: Libertas Academica 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3074208/
https://www.ncbi.nlm.nih.gov/pubmed/21760705
http://dx.doi.org/10.4137/ACI.S5953
_version_ 1782201701066866688
author Narola, Bhavil
Singh, A.S.
Mitra, M.
Santhakumar, P.R.
Chandrashekhar, T.G.
author_facet Narola, Bhavil
Singh, A.S.
Mitra, M.
Santhakumar, P.R.
Chandrashekhar, T.G.
author_sort Narola, Bhavil
collection PubMed
description This paper deals with development and validation of a high performance liquid chromatographic method for the quantitative determination of disodium EDTA (Ethylenediaminetetraacetic acid) in Meropenem active pharmaceutical ingredient (API). EDTA was derivatized with Ferric chloride solution by heating at 70 °C in water bath for about 20 minutes and the chromatographic separation achieved by injecting 100 μL of the derivatized mixture into a Waters HPLC system with photodiode array detector using a Phenomenex Luna C18(2) column (250 × 4.6 mm), 5 μ. The mobile phase consisting of 5% methanol and 95% of 0.7 g/L solution of Tetra butyl ammonium bromide and 4.6 g/L solution of sodium acetate trihydrate in water (pH adjusted to 4.0 with the help of acetic acid glacial) and a flow rate of 1 milliliter/minute. EDTA eluted at approximately 6 minutes. The method was suitably validated with respect to specificity, linearity of response, precision, accuracy, ruggedness, stability in analytical solution, limit of quantitation and detection and robustness for its intended use.
format Text
id pubmed-3074208
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Libertas Academica
record_format MEDLINE/PubMed
spelling pubmed-30742082011-07-14 A Validated Reverse Phase HPLC Method for the Determination of Disodium EDTA in Meropenem Drug Substance with UV-Detection using Precolumn Derivatization Technique Narola, Bhavil Singh, A.S. Mitra, M. Santhakumar, P.R. Chandrashekhar, T.G. Anal Chem Insights Original Research This paper deals with development and validation of a high performance liquid chromatographic method for the quantitative determination of disodium EDTA (Ethylenediaminetetraacetic acid) in Meropenem active pharmaceutical ingredient (API). EDTA was derivatized with Ferric chloride solution by heating at 70 °C in water bath for about 20 minutes and the chromatographic separation achieved by injecting 100 μL of the derivatized mixture into a Waters HPLC system with photodiode array detector using a Phenomenex Luna C18(2) column (250 × 4.6 mm), 5 μ. The mobile phase consisting of 5% methanol and 95% of 0.7 g/L solution of Tetra butyl ammonium bromide and 4.6 g/L solution of sodium acetate trihydrate in water (pH adjusted to 4.0 with the help of acetic acid glacial) and a flow rate of 1 milliliter/minute. EDTA eluted at approximately 6 minutes. The method was suitably validated with respect to specificity, linearity of response, precision, accuracy, ruggedness, stability in analytical solution, limit of quantitation and detection and robustness for its intended use. Libertas Academica 2011-02-23 /pmc/articles/PMC3074208/ /pubmed/21760705 http://dx.doi.org/10.4137/ACI.S5953 Text en © the author(s), publisher and licensee Libertas Academica Ltd. This is an open access article. Unrestricted non-commercial use is permitted provided the original work is properly cited.
spellingShingle Original Research
Narola, Bhavil
Singh, A.S.
Mitra, M.
Santhakumar, P.R.
Chandrashekhar, T.G.
A Validated Reverse Phase HPLC Method for the Determination of Disodium EDTA in Meropenem Drug Substance with UV-Detection using Precolumn Derivatization Technique
title A Validated Reverse Phase HPLC Method for the Determination of Disodium EDTA in Meropenem Drug Substance with UV-Detection using Precolumn Derivatization Technique
title_full A Validated Reverse Phase HPLC Method for the Determination of Disodium EDTA in Meropenem Drug Substance with UV-Detection using Precolumn Derivatization Technique
title_fullStr A Validated Reverse Phase HPLC Method for the Determination of Disodium EDTA in Meropenem Drug Substance with UV-Detection using Precolumn Derivatization Technique
title_full_unstemmed A Validated Reverse Phase HPLC Method for the Determination of Disodium EDTA in Meropenem Drug Substance with UV-Detection using Precolumn Derivatization Technique
title_short A Validated Reverse Phase HPLC Method for the Determination of Disodium EDTA in Meropenem Drug Substance with UV-Detection using Precolumn Derivatization Technique
title_sort validated reverse phase hplc method for the determination of disodium edta in meropenem drug substance with uv-detection using precolumn derivatization technique
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3074208/
https://www.ncbi.nlm.nih.gov/pubmed/21760705
http://dx.doi.org/10.4137/ACI.S5953
work_keys_str_mv AT narolabhavil avalidatedreversephasehplcmethodforthedeterminationofdisodiumedtainmeropenemdrugsubstancewithuvdetectionusingprecolumnderivatizationtechnique
AT singhas avalidatedreversephasehplcmethodforthedeterminationofdisodiumedtainmeropenemdrugsubstancewithuvdetectionusingprecolumnderivatizationtechnique
AT mitram avalidatedreversephasehplcmethodforthedeterminationofdisodiumedtainmeropenemdrugsubstancewithuvdetectionusingprecolumnderivatizationtechnique
AT santhakumarpr avalidatedreversephasehplcmethodforthedeterminationofdisodiumedtainmeropenemdrugsubstancewithuvdetectionusingprecolumnderivatizationtechnique
AT chandrashekhartg avalidatedreversephasehplcmethodforthedeterminationofdisodiumedtainmeropenemdrugsubstancewithuvdetectionusingprecolumnderivatizationtechnique
AT narolabhavil validatedreversephasehplcmethodforthedeterminationofdisodiumedtainmeropenemdrugsubstancewithuvdetectionusingprecolumnderivatizationtechnique
AT singhas validatedreversephasehplcmethodforthedeterminationofdisodiumedtainmeropenemdrugsubstancewithuvdetectionusingprecolumnderivatizationtechnique
AT mitram validatedreversephasehplcmethodforthedeterminationofdisodiumedtainmeropenemdrugsubstancewithuvdetectionusingprecolumnderivatizationtechnique
AT santhakumarpr validatedreversephasehplcmethodforthedeterminationofdisodiumedtainmeropenemdrugsubstancewithuvdetectionusingprecolumnderivatizationtechnique
AT chandrashekhartg validatedreversephasehplcmethodforthedeterminationofdisodiumedtainmeropenemdrugsubstancewithuvdetectionusingprecolumnderivatizationtechnique