Cargando…

Prosthetic finger phalanges with lifelike skin compliance for low-force social touching interactions

BACKGROUND: Prosthetic arms and hands that can be controlled by the user's electromyography (EMG) signals are emerging. Eventually, these advanced prosthetic devices will be expected to touch and be touched by other people. As realistic as they may look, the currently available prosthetic hands...

Descripción completa

Detalles Bibliográficos
Autores principales: Cabibihan, John-John, Pradipta, Raditya, Ge, Shuzhi Sam
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3074547/
https://www.ncbi.nlm.nih.gov/pubmed/21447188
http://dx.doi.org/10.1186/1743-0003-8-16
_version_ 1782201724085207040
author Cabibihan, John-John
Pradipta, Raditya
Ge, Shuzhi Sam
author_facet Cabibihan, John-John
Pradipta, Raditya
Ge, Shuzhi Sam
author_sort Cabibihan, John-John
collection PubMed
description BACKGROUND: Prosthetic arms and hands that can be controlled by the user's electromyography (EMG) signals are emerging. Eventually, these advanced prosthetic devices will be expected to touch and be touched by other people. As realistic as they may look, the currently available prosthetic hands have physical properties that are still far from the characteristics of human skins because they are much stiffer. In this paper, different configurations of synthetic finger phalanges have been investigated for their skin compliance behaviour and have been compared with the phalanges of the human fingers and a phalanx from a commercially available prosthetic hand. METHODS: Handshake tests were performed to identify which areas on the human hand experience high contact forces. After these areas were determined, experiments were done on selected areas using an indenting probe to obtain the force-displacement curves. Finite element simulations were used to compare the force-displacement results of the synthetic finger phalanx designs with that of the experimental results from the human and prosthetic finger phalanges. The simulation models were used to investigate the effects of (a) varying the internal topology of the finger phalanx and (b) varying different materials for the internal and external layers. RESULTS AND CONCLUSIONS: During handshake, the high magnitudes of contact forces were observed at the areas where the full grasping enclosure of the other person's hand can be achieved. From these areas, the middle phalanges of the (a) little, (b) ring, and (c) middle fingers were selected. The indentation experiments on these areas showed that a 2 N force corresponds to skin tissue displacements of more than 2 mm. The results from the simulation model show that introducing an open pocket with 2 mm height on the internal structure of synthetic finger phalanges increased the skin compliance of the silicone material to 235% and the polyurethane material to 436%, as compared to a configuration with a solid internal geometry. In addition, the study shows that an indentation of 2 N force on the synthetic skin with an open pocket can also achieve a displacement of more than 2 mm, while the finger phalanx from a commercially available prosthetic hand can only achieve 0.2 mm.
format Text
id pubmed-3074547
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-30745472011-04-13 Prosthetic finger phalanges with lifelike skin compliance for low-force social touching interactions Cabibihan, John-John Pradipta, Raditya Ge, Shuzhi Sam J Neuroeng Rehabil Research BACKGROUND: Prosthetic arms and hands that can be controlled by the user's electromyography (EMG) signals are emerging. Eventually, these advanced prosthetic devices will be expected to touch and be touched by other people. As realistic as they may look, the currently available prosthetic hands have physical properties that are still far from the characteristics of human skins because they are much stiffer. In this paper, different configurations of synthetic finger phalanges have been investigated for their skin compliance behaviour and have been compared with the phalanges of the human fingers and a phalanx from a commercially available prosthetic hand. METHODS: Handshake tests were performed to identify which areas on the human hand experience high contact forces. After these areas were determined, experiments were done on selected areas using an indenting probe to obtain the force-displacement curves. Finite element simulations were used to compare the force-displacement results of the synthetic finger phalanx designs with that of the experimental results from the human and prosthetic finger phalanges. The simulation models were used to investigate the effects of (a) varying the internal topology of the finger phalanx and (b) varying different materials for the internal and external layers. RESULTS AND CONCLUSIONS: During handshake, the high magnitudes of contact forces were observed at the areas where the full grasping enclosure of the other person's hand can be achieved. From these areas, the middle phalanges of the (a) little, (b) ring, and (c) middle fingers were selected. The indentation experiments on these areas showed that a 2 N force corresponds to skin tissue displacements of more than 2 mm. The results from the simulation model show that introducing an open pocket with 2 mm height on the internal structure of synthetic finger phalanges increased the skin compliance of the silicone material to 235% and the polyurethane material to 436%, as compared to a configuration with a solid internal geometry. In addition, the study shows that an indentation of 2 N force on the synthetic skin with an open pocket can also achieve a displacement of more than 2 mm, while the finger phalanx from a commercially available prosthetic hand can only achieve 0.2 mm. BioMed Central 2011-03-30 /pmc/articles/PMC3074547/ /pubmed/21447188 http://dx.doi.org/10.1186/1743-0003-8-16 Text en Copyright ©2011 Cabibihan et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Cabibihan, John-John
Pradipta, Raditya
Ge, Shuzhi Sam
Prosthetic finger phalanges with lifelike skin compliance for low-force social touching interactions
title Prosthetic finger phalanges with lifelike skin compliance for low-force social touching interactions
title_full Prosthetic finger phalanges with lifelike skin compliance for low-force social touching interactions
title_fullStr Prosthetic finger phalanges with lifelike skin compliance for low-force social touching interactions
title_full_unstemmed Prosthetic finger phalanges with lifelike skin compliance for low-force social touching interactions
title_short Prosthetic finger phalanges with lifelike skin compliance for low-force social touching interactions
title_sort prosthetic finger phalanges with lifelike skin compliance for low-force social touching interactions
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3074547/
https://www.ncbi.nlm.nih.gov/pubmed/21447188
http://dx.doi.org/10.1186/1743-0003-8-16
work_keys_str_mv AT cabibihanjohnjohn prostheticfingerphalangeswithlifelikeskincomplianceforlowforcesocialtouchinginteractions
AT pradiptaraditya prostheticfingerphalangeswithlifelikeskincomplianceforlowforcesocialtouchinginteractions
AT geshuzhisam prostheticfingerphalangeswithlifelikeskincomplianceforlowforcesocialtouchinginteractions