PURPOSE: This study investigated the strain of implants using a chewing simulator with strain gauges in mandibular implant-supported fixed prostheses under various dynamic loads. MATERIALS AND METHODS: Three implant-supported 5-unit fixed prostheses were fabricated with three different occlusion typ...
Autores principales: | , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
The Korean Academy of Prosthodontics
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3076566/ https://www.ncbi.nlm.nih.gov/pubmed/21503186 http://dx.doi.org/10.4047/jap.2011.3.1.1 |
_version_ | 1782201844159741952 |
---|---|
author | Sohn, Byoung-Sup Heo, Seong-Joo Koak, Jai-Young Kim, Seong-Kyun Lee, Su-Young |
author_facet | Sohn, Byoung-Sup Heo, Seong-Joo Koak, Jai-Young Kim, Seong-Kyun Lee, Su-Young |
author_sort | Sohn, Byoung-Sup |
collection | PubMed |
description | PURPOSE: This study investigated the strain of implants using a chewing simulator with strain gauges in mandibular implant-supported fixed prostheses under various dynamic loads. MATERIALS AND METHODS: Three implant-supported 5-unit fixed prostheses were fabricated with three different occlusion types (Group I: Canine protected occlusion, Group II: Unilaterally balanced occlusion, Group III: Bilaterally balanced occlusion). Two strain gauges were attached to each implant abutment. The programmed dynamic loads (0 - 300 N) were applied using a chewing simulator (MTS 858 Mini Bionix II systems, MTS systems corp., Minn, USA) and the strains were monitored. The statistical analyses were performed using the paired t-test and the ANOVA. RESULTS: The mean strain values (MSV) for the working sides were 151.83 µε, 176.23 µε, and 131.07 µε for Group I, Group II, and Group III, respectively. There was a significant difference between Group II and Group III (P < .05). Also, the MSV for non-working side were 58.29 µε, 72.64 µε, and 98.93 µε for Group I, Group II, and Group III, respectively. One was significantly different from the others with a 95% confidence interval (P < .05). CONCLUSION: The MSV for the working side of Groups I and II were significantly different from that for the non-working side (Group I: t = 7.58, Group II: t = 6.25). The MSV for the working side of Group II showed significantly larger than that of Group III (P < .01). Lastly, the MSV for the non-working side of Group III showed significantly larger than those of Group I or Group II (P < .01). |
format | Text |
id | pubmed-3076566 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | The Korean Academy of Prosthodontics |
record_format | MEDLINE/PubMed |
spelling | pubmed-30765662011-04-18 Strain of implants depending on occlusion types in mandibular implant-supported fixed prostheses Sohn, Byoung-Sup Heo, Seong-Joo Koak, Jai-Young Kim, Seong-Kyun Lee, Su-Young J Adv Prosthodont Original Article PURPOSE: This study investigated the strain of implants using a chewing simulator with strain gauges in mandibular implant-supported fixed prostheses under various dynamic loads. MATERIALS AND METHODS: Three implant-supported 5-unit fixed prostheses were fabricated with three different occlusion types (Group I: Canine protected occlusion, Group II: Unilaterally balanced occlusion, Group III: Bilaterally balanced occlusion). Two strain gauges were attached to each implant abutment. The programmed dynamic loads (0 - 300 N) were applied using a chewing simulator (MTS 858 Mini Bionix II systems, MTS systems corp., Minn, USA) and the strains were monitored. The statistical analyses were performed using the paired t-test and the ANOVA. RESULTS: The mean strain values (MSV) for the working sides were 151.83 µε, 176.23 µε, and 131.07 µε for Group I, Group II, and Group III, respectively. There was a significant difference between Group II and Group III (P < .05). Also, the MSV for non-working side were 58.29 µε, 72.64 µε, and 98.93 µε for Group I, Group II, and Group III, respectively. One was significantly different from the others with a 95% confidence interval (P < .05). CONCLUSION: The MSV for the working side of Groups I and II were significantly different from that for the non-working side (Group I: t = 7.58, Group II: t = 6.25). The MSV for the working side of Group II showed significantly larger than that of Group III (P < .01). Lastly, the MSV for the non-working side of Group III showed significantly larger than those of Group I or Group II (P < .01). The Korean Academy of Prosthodontics 2011-03 2011-03-31 /pmc/articles/PMC3076566/ /pubmed/21503186 http://dx.doi.org/10.4047/jap.2011.3.1.1 Text en © 2011 The Korean Academy of Prosthodontics http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Sohn, Byoung-Sup Heo, Seong-Joo Koak, Jai-Young Kim, Seong-Kyun Lee, Su-Young Strain of implants depending on occlusion types in mandibular implant-supported fixed prostheses |
title | Strain of implants depending on occlusion types in mandibular implant-supported fixed prostheses |
title_full | Strain of implants depending on occlusion types in mandibular implant-supported fixed prostheses |
title_fullStr | Strain of implants depending on occlusion types in mandibular implant-supported fixed prostheses |
title_full_unstemmed | Strain of implants depending on occlusion types in mandibular implant-supported fixed prostheses |
title_short | Strain of implants depending on occlusion types in mandibular implant-supported fixed prostheses |
title_sort | strain of implants depending on occlusion types in mandibular implant-supported fixed prostheses |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3076566/ https://www.ncbi.nlm.nih.gov/pubmed/21503186 http://dx.doi.org/10.4047/jap.2011.3.1.1 |
work_keys_str_mv | AT sohnbyoungsup strainofimplantsdependingonocclusiontypesinmandibularimplantsupportedfixedprostheses AT heoseongjoo strainofimplantsdependingonocclusiontypesinmandibularimplantsupportedfixedprostheses AT koakjaiyoung strainofimplantsdependingonocclusiontypesinmandibularimplantsupportedfixedprostheses AT kimseongkyun strainofimplantsdependingonocclusiontypesinmandibularimplantsupportedfixedprostheses AT leesuyoung strainofimplantsdependingonocclusiontypesinmandibularimplantsupportedfixedprostheses |