Cargando…
Simple flow cytometric detection of haemozoin containing leukocytes and erythrocytes for research on diagnosis, immunology and drug sensitivity testing
BACKGROUND: Malaria pigment (haemozoin, Hz) has been the focus of diverse research efforts. However, identification of Hz-containing leukocytes or parasitized erythrocytes is usually based on microscopy, with inherent limitations. Flow cytometric detection of depolarized Side-Scatter is more accurat...
Autores principales: | , , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3078904/ https://www.ncbi.nlm.nih.gov/pubmed/21453521 http://dx.doi.org/10.1186/1475-2875-10-74 |
_version_ | 1782201986761883648 |
---|---|
author | Frita, Rosangela Rebelo, Maria Pamplona, Ana Vigario, Ana M Mota, Maria M Grobusch, Martin P Hänscheid, Thomas |
author_facet | Frita, Rosangela Rebelo, Maria Pamplona, Ana Vigario, Ana M Mota, Maria M Grobusch, Martin P Hänscheid, Thomas |
author_sort | Frita, Rosangela |
collection | PubMed |
description | BACKGROUND: Malaria pigment (haemozoin, Hz) has been the focus of diverse research efforts. However, identification of Hz-containing leukocytes or parasitized erythrocytes is usually based on microscopy, with inherent limitations. Flow cytometric detection of depolarized Side-Scatter is more accurate and its adaptation to common bench top flow cytometers might allow several applications. These can range from the ex-vivo and in-vitro detection and functional analysis of Hz-containing leukocytes to the detection of parasitized Red-Blood-Cells (pRBCs) to assess antimalarial activity. METHODS: A standard benchtop flow cytometer was adapted to detect depolarized Side-Scatter. Synthetic and Plasmodium falciparum Hz were incubated with whole blood and PBMCs to detect Hz-containing leukocytes and CD16 expression on monocytes. C5BL/6 mice were infected with Plasmodium berghei ANKA or P. berghei NK65 and Hz-containing leukocytes were analysed using CD11b and Gr1 expression. Parasitized RBC from infected mice were identified using anti-Ter119 and SYBR green I and were analysed for depolarized Side Scatter. A highly depolarizing RBC population was monitored in an in-vitro culture incubated with chloroquine or quinine. RESULTS: A flow cytometer can be easily adapted to detect depolarized Side-Scatter and thus, intracellular Hz. The detection and counting of Hz containing leukocytes in fresh human or mouse blood, as well as in leukocytes from in-vitro experiments was rapid and easy. Analysis of CD14/CD16 and CD11b/Gr1 monocyte expression in human or mouse blood, in a mixed populations of Hz-containing and non-containing monocytes, appears to show distinct patterns in both types of cells. Hz-containing pRBC and different maturation stages could be detected in blood from infected mice. The analysis of a highly depolarizing population that contained mature pRBC allowed to assess the effect of chloroquine and quinine after only 2 and 4 hours, respectively. CONCLUSIONS: A simple modification of a flow cytometer allows for rapid and reliable detection and quantification of Hz-containing leukocytes and the analysis of differential surface marker expression in the same sample of Hz-containing versus non-Hz-containing leukocytes. Importantly, it distinguishes different maturation stages of parasitized RBC and may be the basis of a rapid no-added-reagent drug sensitivity assay. |
format | Text |
id | pubmed-3078904 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-30789042011-04-19 Simple flow cytometric detection of haemozoin containing leukocytes and erythrocytes for research on diagnosis, immunology and drug sensitivity testing Frita, Rosangela Rebelo, Maria Pamplona, Ana Vigario, Ana M Mota, Maria M Grobusch, Martin P Hänscheid, Thomas Malar J Methodology BACKGROUND: Malaria pigment (haemozoin, Hz) has been the focus of diverse research efforts. However, identification of Hz-containing leukocytes or parasitized erythrocytes is usually based on microscopy, with inherent limitations. Flow cytometric detection of depolarized Side-Scatter is more accurate and its adaptation to common bench top flow cytometers might allow several applications. These can range from the ex-vivo and in-vitro detection and functional analysis of Hz-containing leukocytes to the detection of parasitized Red-Blood-Cells (pRBCs) to assess antimalarial activity. METHODS: A standard benchtop flow cytometer was adapted to detect depolarized Side-Scatter. Synthetic and Plasmodium falciparum Hz were incubated with whole blood and PBMCs to detect Hz-containing leukocytes and CD16 expression on monocytes. C5BL/6 mice were infected with Plasmodium berghei ANKA or P. berghei NK65 and Hz-containing leukocytes were analysed using CD11b and Gr1 expression. Parasitized RBC from infected mice were identified using anti-Ter119 and SYBR green I and were analysed for depolarized Side Scatter. A highly depolarizing RBC population was monitored in an in-vitro culture incubated with chloroquine or quinine. RESULTS: A flow cytometer can be easily adapted to detect depolarized Side-Scatter and thus, intracellular Hz. The detection and counting of Hz containing leukocytes in fresh human or mouse blood, as well as in leukocytes from in-vitro experiments was rapid and easy. Analysis of CD14/CD16 and CD11b/Gr1 monocyte expression in human or mouse blood, in a mixed populations of Hz-containing and non-containing monocytes, appears to show distinct patterns in both types of cells. Hz-containing pRBC and different maturation stages could be detected in blood from infected mice. The analysis of a highly depolarizing population that contained mature pRBC allowed to assess the effect of chloroquine and quinine after only 2 and 4 hours, respectively. CONCLUSIONS: A simple modification of a flow cytometer allows for rapid and reliable detection and quantification of Hz-containing leukocytes and the analysis of differential surface marker expression in the same sample of Hz-containing versus non-Hz-containing leukocytes. Importantly, it distinguishes different maturation stages of parasitized RBC and may be the basis of a rapid no-added-reagent drug sensitivity assay. BioMed Central 2011-03-31 /pmc/articles/PMC3078904/ /pubmed/21453521 http://dx.doi.org/10.1186/1475-2875-10-74 Text en Copyright ©2011 Frita et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Methodology Frita, Rosangela Rebelo, Maria Pamplona, Ana Vigario, Ana M Mota, Maria M Grobusch, Martin P Hänscheid, Thomas Simple flow cytometric detection of haemozoin containing leukocytes and erythrocytes for research on diagnosis, immunology and drug sensitivity testing |
title | Simple flow cytometric detection of haemozoin containing leukocytes and erythrocytes for research on diagnosis, immunology and drug sensitivity testing |
title_full | Simple flow cytometric detection of haemozoin containing leukocytes and erythrocytes for research on diagnosis, immunology and drug sensitivity testing |
title_fullStr | Simple flow cytometric detection of haemozoin containing leukocytes and erythrocytes for research on diagnosis, immunology and drug sensitivity testing |
title_full_unstemmed | Simple flow cytometric detection of haemozoin containing leukocytes and erythrocytes for research on diagnosis, immunology and drug sensitivity testing |
title_short | Simple flow cytometric detection of haemozoin containing leukocytes and erythrocytes for research on diagnosis, immunology and drug sensitivity testing |
title_sort | simple flow cytometric detection of haemozoin containing leukocytes and erythrocytes for research on diagnosis, immunology and drug sensitivity testing |
topic | Methodology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3078904/ https://www.ncbi.nlm.nih.gov/pubmed/21453521 http://dx.doi.org/10.1186/1475-2875-10-74 |
work_keys_str_mv | AT fritarosangela simpleflowcytometricdetectionofhaemozoincontainingleukocytesanderythrocytesforresearchondiagnosisimmunologyanddrugsensitivitytesting AT rebelomaria simpleflowcytometricdetectionofhaemozoincontainingleukocytesanderythrocytesforresearchondiagnosisimmunologyanddrugsensitivitytesting AT pamplonaana simpleflowcytometricdetectionofhaemozoincontainingleukocytesanderythrocytesforresearchondiagnosisimmunologyanddrugsensitivitytesting AT vigarioanam simpleflowcytometricdetectionofhaemozoincontainingleukocytesanderythrocytesforresearchondiagnosisimmunologyanddrugsensitivitytesting AT motamariam simpleflowcytometricdetectionofhaemozoincontainingleukocytesanderythrocytesforresearchondiagnosisimmunologyanddrugsensitivitytesting AT grobuschmartinp simpleflowcytometricdetectionofhaemozoincontainingleukocytesanderythrocytesforresearchondiagnosisimmunologyanddrugsensitivitytesting AT hanscheidthomas simpleflowcytometricdetectionofhaemozoincontainingleukocytesanderythrocytesforresearchondiagnosisimmunologyanddrugsensitivitytesting |