Cargando…
Clinical implementation of the hysteroscopic morcellator for removal of intrauterine myomas and polyps. A retrospective descriptive study
The aim of this study is to report our experience with a novel technique, the hysteroscopic morcellator (HM), for removal of intrauterine myomas and polyps. We performed a retrospective study on 315 women undergoing operative hysteroscopy with the HM in our university-affiliated teaching hospital. W...
Autores principales: | , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Springer-Verlag
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3083510/ https://www.ncbi.nlm.nih.gov/pubmed/21654903 http://dx.doi.org/10.1007/s10397-010-0627-7 |
_version_ | 1782202408416313344 |
---|---|
author | Hamerlynck, Tjalina Wibeke Oona Dietz, Viviane Schoot, Benedictus Christiaan |
author_facet | Hamerlynck, Tjalina Wibeke Oona Dietz, Viviane Schoot, Benedictus Christiaan |
author_sort | Hamerlynck, Tjalina Wibeke Oona |
collection | PubMed |
description | The aim of this study is to report our experience with a novel technique, the hysteroscopic morcellator (HM), for removal of intrauterine myomas and polyps. We performed a retrospective study on 315 women undergoing operative hysteroscopy with the HM in our university-affiliated teaching hospital. We collected data on installation and operating times, fluid deficit, peri- and postoperative complications. In 37 patients undergoing myomectomy with the HM, mean installation time was 8.7 min, mean operating time, 18.2 min, and median fluid deficit, 440 mL. Three out of 37 HM procedures were converted to resectoscopy, related to a type 2 myoma. In 278 patients, mean installation and operating times for polypectomy with the HM were 7.3 min and 6.6 min, respectively. All procedures were uneventful. Implementation of the HM for removal of type 0 and 1 myomas ≤3 cm, and removal of polyps appears safe and effective. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s10397-010-0627-7) contains supplementary material, which is available to authorized users. |
format | Text |
id | pubmed-3083510 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | Springer-Verlag |
record_format | MEDLINE/PubMed |
spelling | pubmed-30835102011-06-06 Clinical implementation of the hysteroscopic morcellator for removal of intrauterine myomas and polyps. A retrospective descriptive study Hamerlynck, Tjalina Wibeke Oona Dietz, Viviane Schoot, Benedictus Christiaan Gynecol Surg Techniques and Instrumentation The aim of this study is to report our experience with a novel technique, the hysteroscopic morcellator (HM), for removal of intrauterine myomas and polyps. We performed a retrospective study on 315 women undergoing operative hysteroscopy with the HM in our university-affiliated teaching hospital. We collected data on installation and operating times, fluid deficit, peri- and postoperative complications. In 37 patients undergoing myomectomy with the HM, mean installation time was 8.7 min, mean operating time, 18.2 min, and median fluid deficit, 440 mL. Three out of 37 HM procedures were converted to resectoscopy, related to a type 2 myoma. In 278 patients, mean installation and operating times for polypectomy with the HM were 7.3 min and 6.6 min, respectively. All procedures were uneventful. Implementation of the HM for removal of type 0 and 1 myomas ≤3 cm, and removal of polyps appears safe and effective. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s10397-010-0627-7) contains supplementary material, which is available to authorized users. Springer-Verlag 2010-09-21 2011 /pmc/articles/PMC3083510/ /pubmed/21654903 http://dx.doi.org/10.1007/s10397-010-0627-7 Text en © The Author(s) 2010 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited. |
spellingShingle | Techniques and Instrumentation Hamerlynck, Tjalina Wibeke Oona Dietz, Viviane Schoot, Benedictus Christiaan Clinical implementation of the hysteroscopic morcellator for removal of intrauterine myomas and polyps. A retrospective descriptive study |
title | Clinical implementation of the hysteroscopic morcellator for removal of intrauterine myomas and polyps. A retrospective descriptive study |
title_full | Clinical implementation of the hysteroscopic morcellator for removal of intrauterine myomas and polyps. A retrospective descriptive study |
title_fullStr | Clinical implementation of the hysteroscopic morcellator for removal of intrauterine myomas and polyps. A retrospective descriptive study |
title_full_unstemmed | Clinical implementation of the hysteroscopic morcellator for removal of intrauterine myomas and polyps. A retrospective descriptive study |
title_short | Clinical implementation of the hysteroscopic morcellator for removal of intrauterine myomas and polyps. A retrospective descriptive study |
title_sort | clinical implementation of the hysteroscopic morcellator for removal of intrauterine myomas and polyps. a retrospective descriptive study |
topic | Techniques and Instrumentation |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3083510/ https://www.ncbi.nlm.nih.gov/pubmed/21654903 http://dx.doi.org/10.1007/s10397-010-0627-7 |
work_keys_str_mv | AT hamerlyncktjalinawibekeoona clinicalimplementationofthehysteroscopicmorcellatorforremovalofintrauterinemyomasandpolypsaretrospectivedescriptivestudy AT dietzviviane clinicalimplementationofthehysteroscopicmorcellatorforremovalofintrauterinemyomasandpolypsaretrospectivedescriptivestudy AT schootbenedictuschristiaan clinicalimplementationofthehysteroscopicmorcellatorforremovalofintrauterinemyomasandpolypsaretrospectivedescriptivestudy |