Cargando…
Masticatory function following implants replacing a second molar
PURPOSE: The aim of this study was to obtain objective and standardized information on masticatory function and patient satisfaction following second molar single implant therapy. METHODS: Twenty adult patients, who had restored second molar single implants more than 1 month before the study, were e...
Autores principales: | , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Korean Academy of Periodontology
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3087079/ https://www.ncbi.nlm.nih.gov/pubmed/21556258 http://dx.doi.org/10.5051/jpis.2011.41.2.79 |
_version_ | 1782202735347630080 |
---|---|
author | Kim, Moon-Sun Lee, Jae-Kwan Chang, Beom-Seok Um, Heung-Sik |
author_facet | Kim, Moon-Sun Lee, Jae-Kwan Chang, Beom-Seok Um, Heung-Sik |
author_sort | Kim, Moon-Sun |
collection | PubMed |
description | PURPOSE: The aim of this study was to obtain objective and standardized information on masticatory function and patient satisfaction following second molar single implant therapy. METHODS: Twenty adult patients, who had restored second molar single implants more than 1 month before the study, were enrolled in this study. All patients received a chewing test using peanuts before and after insertion of the implant prosthesis, with a questionnaire and visual analogue scale (VAS) to evaluate the effect of second molar single implant therapy. RESULTS: This study obtained standardized information on the masticatory function objectively (e.g., P, R, X(50)) before (Pre-insertion) and after insertion (Post-insertion) of the implant prosthesis. Masticatory performance (P) after insertion of the implant prosthesis significantly increased from 67.8±9.9 to 84.3±8.5% (P<0.0001). With the implant prosthesis, the P value increased by 24%. The masticatory efficiency index (R) of Post-insertion is higher than that of Pre-insertion (P<0.0001). With the implant prosthesis, the R value increased by 29%. The median particle size (X(50)) of Post-insertion is lower than that of Pre-insertion (P<0.0001). More than 90% of the patients were satisfied with the second molar single implant therapy from a functional point of view. CONCLUSIONS: These findings indicate that a second molar single implant can increase masticatory function. |
format | Text |
id | pubmed-3087079 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Korean Academy of Periodontology |
record_format | MEDLINE/PubMed |
spelling | pubmed-30870792011-05-09 Masticatory function following implants replacing a second molar Kim, Moon-Sun Lee, Jae-Kwan Chang, Beom-Seok Um, Heung-Sik J Periodontal Implant Sci Research Article PURPOSE: The aim of this study was to obtain objective and standardized information on masticatory function and patient satisfaction following second molar single implant therapy. METHODS: Twenty adult patients, who had restored second molar single implants more than 1 month before the study, were enrolled in this study. All patients received a chewing test using peanuts before and after insertion of the implant prosthesis, with a questionnaire and visual analogue scale (VAS) to evaluate the effect of second molar single implant therapy. RESULTS: This study obtained standardized information on the masticatory function objectively (e.g., P, R, X(50)) before (Pre-insertion) and after insertion (Post-insertion) of the implant prosthesis. Masticatory performance (P) after insertion of the implant prosthesis significantly increased from 67.8±9.9 to 84.3±8.5% (P<0.0001). With the implant prosthesis, the P value increased by 24%. The masticatory efficiency index (R) of Post-insertion is higher than that of Pre-insertion (P<0.0001). With the implant prosthesis, the R value increased by 29%. The median particle size (X(50)) of Post-insertion is lower than that of Pre-insertion (P<0.0001). More than 90% of the patients were satisfied with the second molar single implant therapy from a functional point of view. CONCLUSIONS: These findings indicate that a second molar single implant can increase masticatory function. Korean Academy of Periodontology 2011-04 2011-04-29 /pmc/articles/PMC3087079/ /pubmed/21556258 http://dx.doi.org/10.5051/jpis.2011.41.2.79 Text en Copyright © 2011 Korean Academy of Periodontology This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/). |
spellingShingle | Research Article Kim, Moon-Sun Lee, Jae-Kwan Chang, Beom-Seok Um, Heung-Sik Masticatory function following implants replacing a second molar |
title | Masticatory function following implants replacing a second molar |
title_full | Masticatory function following implants replacing a second molar |
title_fullStr | Masticatory function following implants replacing a second molar |
title_full_unstemmed | Masticatory function following implants replacing a second molar |
title_short | Masticatory function following implants replacing a second molar |
title_sort | masticatory function following implants replacing a second molar |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3087079/ https://www.ncbi.nlm.nih.gov/pubmed/21556258 http://dx.doi.org/10.5051/jpis.2011.41.2.79 |
work_keys_str_mv | AT kimmoonsun masticatoryfunctionfollowingimplantsreplacingasecondmolar AT leejaekwan masticatoryfunctionfollowingimplantsreplacingasecondmolar AT changbeomseok masticatoryfunctionfollowingimplantsreplacingasecondmolar AT umheungsik masticatoryfunctionfollowingimplantsreplacingasecondmolar |