PLMA vs. I-gel: A Comparative Evaluation of Respiratory Mechanics in Laparoscopic Cholecystectomy

BACKGROUND: Supraglottic airway devices (SADs), such as ProSealTM laryngeal mask airway (PLMA), which produce high oropharyngeal seal pressure (OSP) and have the facility for gastric decompression have been used in laparoscopic procedures. i-gel is a new SAD which shares these features with the PLMA...

Descripción completa

Detalles Bibliográficos
Autores principales: Sharma, Bimla, Sehgal, Raminder, Sahai, Chand, Sood, Jayashree
Formato: Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3087251/
https://www.ncbi.nlm.nih.gov/pubmed/21547168
_version_ 1782202752842072064
author Sharma, Bimla
Sehgal, Raminder
Sahai, Chand
Sood, Jayashree
author_facet Sharma, Bimla
Sehgal, Raminder
Sahai, Chand
Sood, Jayashree
author_sort Sharma, Bimla
collection PubMed
description BACKGROUND: Supraglottic airway devices (SADs), such as ProSealTM laryngeal mask airway (PLMA), which produce high oropharyngeal seal pressure (OSP) and have the facility for gastric decompression have been used in laparoscopic procedures. i-gel is a new SAD which shares these features with the PLMA. This study was designed to compare the respiratory mechanics of these two devices during positive pressure ventilation in anaesthetised adult patients undergoing laparoscopic cholecystectomy. PATIENTS & METHODS: The study included 60 ASA I-II adult patients scheduled for laparoscopic cholecystectomy. The patients were randomized to two groups of 30 each, with either PLMA or i-gel as their airway device. Anaesthesia and premedication were standardized for both the groups. In addition to routine monitoring, neuromuscular monitoring with TOF ratio, OSP and respiratory mechanics monitoring (dynamic compliance, resistance, work of breathing, measured minute ventilation and peak airway pressures) were employed. Fibreoptic evaluation of positioning of the devices and adverse events related to them were also compared. RESULTS: The OSP (cm H2O) were higher for PLMA (38.9 vs. 35.6, P=0.007). The respiratory mechanics parameters using the two devices were comparable apart from the dynamic compliance, which was significantly higher with i-gel (P < 0.05). Malrotation was higher with i-gel than with PLMA (15 vs. 5, P = 0.006). CONCLUSION: The PLMA formed a better seal while the dynamic compliance was higher with the i-gel. Both devices provided optimal ventilation and oxygenation and the adverse events were also comparable.
format Text
id pubmed-3087251
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-30872512011-05-05 PLMA vs. I-gel: A Comparative Evaluation of Respiratory Mechanics in Laparoscopic Cholecystectomy Sharma, Bimla Sehgal, Raminder Sahai, Chand Sood, Jayashree J Anaesthesiol Clin Pharmacol Research Papers BACKGROUND: Supraglottic airway devices (SADs), such as ProSealTM laryngeal mask airway (PLMA), which produce high oropharyngeal seal pressure (OSP) and have the facility for gastric decompression have been used in laparoscopic procedures. i-gel is a new SAD which shares these features with the PLMA. This study was designed to compare the respiratory mechanics of these two devices during positive pressure ventilation in anaesthetised adult patients undergoing laparoscopic cholecystectomy. PATIENTS & METHODS: The study included 60 ASA I-II adult patients scheduled for laparoscopic cholecystectomy. The patients were randomized to two groups of 30 each, with either PLMA or i-gel as their airway device. Anaesthesia and premedication were standardized for both the groups. In addition to routine monitoring, neuromuscular monitoring with TOF ratio, OSP and respiratory mechanics monitoring (dynamic compliance, resistance, work of breathing, measured minute ventilation and peak airway pressures) were employed. Fibreoptic evaluation of positioning of the devices and adverse events related to them were also compared. RESULTS: The OSP (cm H2O) were higher for PLMA (38.9 vs. 35.6, P=0.007). The respiratory mechanics parameters using the two devices were comparable apart from the dynamic compliance, which was significantly higher with i-gel (P < 0.05). Malrotation was higher with i-gel than with PLMA (15 vs. 5, P = 0.006). CONCLUSION: The PLMA formed a better seal while the dynamic compliance was higher with the i-gel. Both devices provided optimal ventilation and oxygenation and the adverse events were also comparable. Medknow Publications & Media Pvt Ltd 2010 /pmc/articles/PMC3087251/ /pubmed/21547168 Text en Copyright: © Journal of Anaesthesiology Clinical Pharmacology http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Papers
Sharma, Bimla
Sehgal, Raminder
Sahai, Chand
Sood, Jayashree
PLMA vs. I-gel: A Comparative Evaluation of Respiratory Mechanics in Laparoscopic Cholecystectomy
title PLMA vs. I-gel: A Comparative Evaluation of Respiratory Mechanics in Laparoscopic Cholecystectomy
title_full PLMA vs. I-gel: A Comparative Evaluation of Respiratory Mechanics in Laparoscopic Cholecystectomy
title_fullStr PLMA vs. I-gel: A Comparative Evaluation of Respiratory Mechanics in Laparoscopic Cholecystectomy
title_full_unstemmed PLMA vs. I-gel: A Comparative Evaluation of Respiratory Mechanics in Laparoscopic Cholecystectomy
title_short PLMA vs. I-gel: A Comparative Evaluation of Respiratory Mechanics in Laparoscopic Cholecystectomy
title_sort plma vs. i-gel: a comparative evaluation of respiratory mechanics in laparoscopic cholecystectomy
topic Research Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3087251/
https://www.ncbi.nlm.nih.gov/pubmed/21547168
work_keys_str_mv AT sharmabimla plmavsigelacomparativeevaluationofrespiratorymechanicsinlaparoscopiccholecystectomy
AT sehgalraminder plmavsigelacomparativeevaluationofrespiratorymechanicsinlaparoscopiccholecystectomy
AT sahaichand plmavsigelacomparativeevaluationofrespiratorymechanicsinlaparoscopiccholecystectomy
AT soodjayashree plmavsigelacomparativeevaluationofrespiratorymechanicsinlaparoscopiccholecystectomy