Cargando…
PLMA vs. I-gel: A Comparative Evaluation of Respiratory Mechanics in Laparoscopic Cholecystectomy
BACKGROUND: Supraglottic airway devices (SADs), such as ProSealTM laryngeal mask airway (PLMA), which produce high oropharyngeal seal pressure (OSP) and have the facility for gastric decompression have been used in laparoscopic procedures. i-gel is a new SAD which shares these features with the PLMA...
Autores principales: | , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3087251/ https://www.ncbi.nlm.nih.gov/pubmed/21547168 |
_version_ | 1782202752842072064 |
---|---|
author | Sharma, Bimla Sehgal, Raminder Sahai, Chand Sood, Jayashree |
author_facet | Sharma, Bimla Sehgal, Raminder Sahai, Chand Sood, Jayashree |
author_sort | Sharma, Bimla |
collection | PubMed |
description | BACKGROUND: Supraglottic airway devices (SADs), such as ProSealTM laryngeal mask airway (PLMA), which produce high oropharyngeal seal pressure (OSP) and have the facility for gastric decompression have been used in laparoscopic procedures. i-gel is a new SAD which shares these features with the PLMA. This study was designed to compare the respiratory mechanics of these two devices during positive pressure ventilation in anaesthetised adult patients undergoing laparoscopic cholecystectomy. PATIENTS & METHODS: The study included 60 ASA I-II adult patients scheduled for laparoscopic cholecystectomy. The patients were randomized to two groups of 30 each, with either PLMA or i-gel as their airway device. Anaesthesia and premedication were standardized for both the groups. In addition to routine monitoring, neuromuscular monitoring with TOF ratio, OSP and respiratory mechanics monitoring (dynamic compliance, resistance, work of breathing, measured minute ventilation and peak airway pressures) were employed. Fibreoptic evaluation of positioning of the devices and adverse events related to them were also compared. RESULTS: The OSP (cm H2O) were higher for PLMA (38.9 vs. 35.6, P=0.007). The respiratory mechanics parameters using the two devices were comparable apart from the dynamic compliance, which was significantly higher with i-gel (P < 0.05). Malrotation was higher with i-gel than with PLMA (15 vs. 5, P = 0.006). CONCLUSION: The PLMA formed a better seal while the dynamic compliance was higher with the i-gel. Both devices provided optimal ventilation and oxygenation and the adverse events were also comparable. |
format | Text |
id | pubmed-3087251 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-30872512011-05-05 PLMA vs. I-gel: A Comparative Evaluation of Respiratory Mechanics in Laparoscopic Cholecystectomy Sharma, Bimla Sehgal, Raminder Sahai, Chand Sood, Jayashree J Anaesthesiol Clin Pharmacol Research Papers BACKGROUND: Supraglottic airway devices (SADs), such as ProSealTM laryngeal mask airway (PLMA), which produce high oropharyngeal seal pressure (OSP) and have the facility for gastric decompression have been used in laparoscopic procedures. i-gel is a new SAD which shares these features with the PLMA. This study was designed to compare the respiratory mechanics of these two devices during positive pressure ventilation in anaesthetised adult patients undergoing laparoscopic cholecystectomy. PATIENTS & METHODS: The study included 60 ASA I-II adult patients scheduled for laparoscopic cholecystectomy. The patients were randomized to two groups of 30 each, with either PLMA or i-gel as their airway device. Anaesthesia and premedication were standardized for both the groups. In addition to routine monitoring, neuromuscular monitoring with TOF ratio, OSP and respiratory mechanics monitoring (dynamic compliance, resistance, work of breathing, measured minute ventilation and peak airway pressures) were employed. Fibreoptic evaluation of positioning of the devices and adverse events related to them were also compared. RESULTS: The OSP (cm H2O) were higher for PLMA (38.9 vs. 35.6, P=0.007). The respiratory mechanics parameters using the two devices were comparable apart from the dynamic compliance, which was significantly higher with i-gel (P < 0.05). Malrotation was higher with i-gel than with PLMA (15 vs. 5, P = 0.006). CONCLUSION: The PLMA formed a better seal while the dynamic compliance was higher with the i-gel. Both devices provided optimal ventilation and oxygenation and the adverse events were also comparable. Medknow Publications & Media Pvt Ltd 2010 /pmc/articles/PMC3087251/ /pubmed/21547168 Text en Copyright: © Journal of Anaesthesiology Clinical Pharmacology http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Papers Sharma, Bimla Sehgal, Raminder Sahai, Chand Sood, Jayashree PLMA vs. I-gel: A Comparative Evaluation of Respiratory Mechanics in Laparoscopic Cholecystectomy |
title | PLMA vs. I-gel: A Comparative Evaluation of Respiratory Mechanics in Laparoscopic Cholecystectomy |
title_full | PLMA vs. I-gel: A Comparative Evaluation of Respiratory Mechanics in Laparoscopic Cholecystectomy |
title_fullStr | PLMA vs. I-gel: A Comparative Evaluation of Respiratory Mechanics in Laparoscopic Cholecystectomy |
title_full_unstemmed | PLMA vs. I-gel: A Comparative Evaluation of Respiratory Mechanics in Laparoscopic Cholecystectomy |
title_short | PLMA vs. I-gel: A Comparative Evaluation of Respiratory Mechanics in Laparoscopic Cholecystectomy |
title_sort | plma vs. i-gel: a comparative evaluation of respiratory mechanics in laparoscopic cholecystectomy |
topic | Research Papers |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3087251/ https://www.ncbi.nlm.nih.gov/pubmed/21547168 |
work_keys_str_mv | AT sharmabimla plmavsigelacomparativeevaluationofrespiratorymechanicsinlaparoscopiccholecystectomy AT sehgalraminder plmavsigelacomparativeevaluationofrespiratorymechanicsinlaparoscopiccholecystectomy AT sahaichand plmavsigelacomparativeevaluationofrespiratorymechanicsinlaparoscopiccholecystectomy AT soodjayashree plmavsigelacomparativeevaluationofrespiratorymechanicsinlaparoscopiccholecystectomy |