Cargando…

Prospective Single-Arm, Multi-Center Trial of a Patient-Specific Interpositional Knee Implant: Early Clinical Results

BACKGROUND: The treatment of unicompartmental arthritis in younger patients is challenging. The aim of this study is to report final safety and efficacy analysis results for the iForma patient–specific interpositional device, which is designed for the treatment of isolated medial or lateral compartm...

Descripción completa

Detalles Bibliográficos
Autores principales: Koeck, F.X, Luring, C, Goetz, J, Handel, M, Tingart, M, Grifka, J, Beckmann, J
Formato: Texto
Lenguaje:English
Publicado: Bentham Open 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3087285/
https://www.ncbi.nlm.nih.gov/pubmed/21552462
http://dx.doi.org/10.2174/1874325001105010037
_version_ 1782202760968536064
author Koeck, F.X
Luring, C
Goetz, J
Handel, M
Tingart, M
Grifka, J
Beckmann, J
author_facet Koeck, F.X
Luring, C
Goetz, J
Handel, M
Tingart, M
Grifka, J
Beckmann, J
author_sort Koeck, F.X
collection PubMed
description BACKGROUND: The treatment of unicompartmental arthritis in younger patients is challenging. The aim of this study is to report final safety and efficacy analysis results for the iForma patient–specific interpositional device, which is designed for the treatment of isolated medial or lateral compartment arthritis of the knee. METHODS: From June 2005 to June 2008 78 subjects (42 men, 36 women) received an iForma implant. The mean age was 53 years, the mean Body Mass Index 29.0. We surveyed the WOMAC scores, the visual analog pain scale and the Knee Society Scores. RESULTS: The mean follow up was 16.4 months. The mean WOMAC knee scores increased from 48.3 before surgery to 71.3 after 24 months. A reduction in pain was achieved for all five pain measures using a standard visual analog scale (VAS). Knee Society Knee Score improved from 39.2 before to 61.9 24 month after surgery. The Knee Society Function Scores improved form preoperative 64.5 to 82.5 2 years postoperative. The preoperative range of motion could be restored. The overall revision rate was 24%. 15 implants were removed early, 4 knees were revised without implant removal. CONCLUSION: Within narrow indication of patients with unicompartmental disease, the iForma device can provide improvement in knee function and reduction in pain, however, with a significant higher risk of early revision compared to traditional arthroplasty. Respecting this limitation it may be an alternative option for arthritic patients with unicompartmental disease who have contraindications to High Tibial Osteotomy or are too young for knee replacement; the iForma device further has the distinct advantage of time and cost saving compared to those procedures.
format Text
id pubmed-3087285
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Bentham Open
record_format MEDLINE/PubMed
spelling pubmed-30872852011-05-06 Prospective Single-Arm, Multi-Center Trial of a Patient-Specific Interpositional Knee Implant: Early Clinical Results Koeck, F.X Luring, C Goetz, J Handel, M Tingart, M Grifka, J Beckmann, J Open Orthop J Article BACKGROUND: The treatment of unicompartmental arthritis in younger patients is challenging. The aim of this study is to report final safety and efficacy analysis results for the iForma patient–specific interpositional device, which is designed for the treatment of isolated medial or lateral compartment arthritis of the knee. METHODS: From June 2005 to June 2008 78 subjects (42 men, 36 women) received an iForma implant. The mean age was 53 years, the mean Body Mass Index 29.0. We surveyed the WOMAC scores, the visual analog pain scale and the Knee Society Scores. RESULTS: The mean follow up was 16.4 months. The mean WOMAC knee scores increased from 48.3 before surgery to 71.3 after 24 months. A reduction in pain was achieved for all five pain measures using a standard visual analog scale (VAS). Knee Society Knee Score improved from 39.2 before to 61.9 24 month after surgery. The Knee Society Function Scores improved form preoperative 64.5 to 82.5 2 years postoperative. The preoperative range of motion could be restored. The overall revision rate was 24%. 15 implants were removed early, 4 knees were revised without implant removal. CONCLUSION: Within narrow indication of patients with unicompartmental disease, the iForma device can provide improvement in knee function and reduction in pain, however, with a significant higher risk of early revision compared to traditional arthroplasty. Respecting this limitation it may be an alternative option for arthritic patients with unicompartmental disease who have contraindications to High Tibial Osteotomy or are too young for knee replacement; the iForma device further has the distinct advantage of time and cost saving compared to those procedures. Bentham Open 2011-02-09 /pmc/articles/PMC3087285/ /pubmed/21552462 http://dx.doi.org/10.2174/1874325001105010037 Text en © Koeck et al.; Licensee Bentham Open. http://creativecommons.org/licenses/by-nc/3.0/ This is an open access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted, non-commercial use, distribution, and reproduction in any medium, provided the work is properly cited.
spellingShingle Article
Koeck, F.X
Luring, C
Goetz, J
Handel, M
Tingart, M
Grifka, J
Beckmann, J
Prospective Single-Arm, Multi-Center Trial of a Patient-Specific Interpositional Knee Implant: Early Clinical Results
title Prospective Single-Arm, Multi-Center Trial of a Patient-Specific Interpositional Knee Implant: Early Clinical Results
title_full Prospective Single-Arm, Multi-Center Trial of a Patient-Specific Interpositional Knee Implant: Early Clinical Results
title_fullStr Prospective Single-Arm, Multi-Center Trial of a Patient-Specific Interpositional Knee Implant: Early Clinical Results
title_full_unstemmed Prospective Single-Arm, Multi-Center Trial of a Patient-Specific Interpositional Knee Implant: Early Clinical Results
title_short Prospective Single-Arm, Multi-Center Trial of a Patient-Specific Interpositional Knee Implant: Early Clinical Results
title_sort prospective single-arm, multi-center trial of a patient-specific interpositional knee implant: early clinical results
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3087285/
https://www.ncbi.nlm.nih.gov/pubmed/21552462
http://dx.doi.org/10.2174/1874325001105010037
work_keys_str_mv AT koeckfx prospectivesinglearmmulticentertrialofapatientspecificinterpositionalkneeimplantearlyclinicalresults
AT luringc prospectivesinglearmmulticentertrialofapatientspecificinterpositionalkneeimplantearlyclinicalresults
AT goetzj prospectivesinglearmmulticentertrialofapatientspecificinterpositionalkneeimplantearlyclinicalresults
AT handelm prospectivesinglearmmulticentertrialofapatientspecificinterpositionalkneeimplantearlyclinicalresults
AT tingartm prospectivesinglearmmulticentertrialofapatientspecificinterpositionalkneeimplantearlyclinicalresults
AT grifkaj prospectivesinglearmmulticentertrialofapatientspecificinterpositionalkneeimplantearlyclinicalresults
AT beckmannj prospectivesinglearmmulticentertrialofapatientspecificinterpositionalkneeimplantearlyclinicalresults