Cargando…
Reply to “Comment on ‘A study on tetrahedron-based inhomogeneous Monte-Carlo optical simulation’”
We compare the accuracy of TIM-OS and MMCM in response to the recent analysis made by Fang [Biomed. Opt. Express 2, 1258 (2011)]. Our results show that the tetrahedron-based energy deposition algorithm used in TIM-OS is more accurate than the node-based energy deposition algorithm used in MMCM.
Autores principales: | , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Optical Society of America
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3087582/ https://www.ncbi.nlm.nih.gov/pubmed/21559137 http://dx.doi.org/10.1364/BOE.2.001265 |
_version_ | 1782202803253411840 |
---|---|
author | Shen, Haiou Wang, Ge |
author_facet | Shen, Haiou Wang, Ge |
author_sort | Shen, Haiou |
collection | PubMed |
description | We compare the accuracy of TIM-OS and MMCM in response to the recent analysis made by Fang [Biomed. Opt. Express 2, 1258 (2011)]. Our results show that the tetrahedron-based energy deposition algorithm used in TIM-OS is more accurate than the node-based energy deposition algorithm used in MMCM. |
format | Text |
id | pubmed-3087582 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Optical Society of America |
record_format | MEDLINE/PubMed |
spelling | pubmed-30875822011-05-10 Reply to “Comment on ‘A study on tetrahedron-based inhomogeneous Monte-Carlo optical simulation’” Shen, Haiou Wang, Ge Biomed Opt Express Optics of Tissue and Turbid Media We compare the accuracy of TIM-OS and MMCM in response to the recent analysis made by Fang [Biomed. Opt. Express 2, 1258 (2011)]. Our results show that the tetrahedron-based energy deposition algorithm used in TIM-OS is more accurate than the node-based energy deposition algorithm used in MMCM. Optical Society of America 2011-04-19 /pmc/articles/PMC3087582/ /pubmed/21559137 http://dx.doi.org/10.1364/BOE.2.001265 Text en ©2011 Optical Society of America http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-No Derivative Works 3.0 Unported License, which permits download and redistribution, provided that the original work is properly cited. This license restricts the article from being modified or used commercially. |
spellingShingle | Optics of Tissue and Turbid Media Shen, Haiou Wang, Ge Reply to “Comment on ‘A study on tetrahedron-based inhomogeneous Monte-Carlo optical simulation’” |
title | Reply to “Comment on ‘A study on tetrahedron-based inhomogeneous Monte-Carlo optical simulation’” |
title_full | Reply to “Comment on ‘A study on tetrahedron-based inhomogeneous Monte-Carlo optical simulation’” |
title_fullStr | Reply to “Comment on ‘A study on tetrahedron-based inhomogeneous Monte-Carlo optical simulation’” |
title_full_unstemmed | Reply to “Comment on ‘A study on tetrahedron-based inhomogeneous Monte-Carlo optical simulation’” |
title_short | Reply to “Comment on ‘A study on tetrahedron-based inhomogeneous Monte-Carlo optical simulation’” |
title_sort | reply to “comment on ‘a study on tetrahedron-based inhomogeneous monte-carlo optical simulation’” |
topic | Optics of Tissue and Turbid Media |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3087582/ https://www.ncbi.nlm.nih.gov/pubmed/21559137 http://dx.doi.org/10.1364/BOE.2.001265 |
work_keys_str_mv | AT shenhaiou replytocommentonastudyontetrahedronbasedinhomogeneousmontecarloopticalsimulation AT wangge replytocommentonastudyontetrahedronbasedinhomogeneousmontecarloopticalsimulation |