Position-referenced microscopy for live cell culture monitoring

Position-referenced microscopy (PRM) is based on smart sample holders that integrate a position reference pattern (PRP) in their depth, allowing the determination of the lateral coordinates with respect to the sample-holder itself. Regions of interest can thus be retrieved easily after culture dish...

Descripción completa

Detalles Bibliográficos
Autores principales: Galeano Z., July A., Sandoz, Patrick, Gaiffe, Emilie, Launay, Sophie, Robert, Laurent, Jacquot, Maxime, Hirchaud, Fabienne, Prétet, Jean-Luc, Mougin, Christiane
Formato: Texto
Lenguaje:English
Publicado: Optical Society of America 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3087587/
https://www.ncbi.nlm.nih.gov/pubmed/21559142
http://dx.doi.org/10.1364/BOE.2.001307
_version_ 1782202804428865536
author Galeano Z., July A.
Sandoz, Patrick
Gaiffe, Emilie
Launay, Sophie
Robert, Laurent
Jacquot, Maxime
Hirchaud, Fabienne
Prétet, Jean-Luc
Mougin, Christiane
author_facet Galeano Z., July A.
Sandoz, Patrick
Gaiffe, Emilie
Launay, Sophie
Robert, Laurent
Jacquot, Maxime
Hirchaud, Fabienne
Prétet, Jean-Luc
Mougin, Christiane
author_sort Galeano Z., July A.
collection PubMed
description Position-referenced microscopy (PRM) is based on smart sample holders that integrate a position reference pattern (PRP) in their depth, allowing the determination of the lateral coordinates with respect to the sample-holder itself. Regions of interest can thus be retrieved easily after culture dish transfers from a cell incubator to the microscope stage. Images recorded at different instants in time are superimposed in a common coordinate system with subpixel accuracy. This paper presents such smart Petri culture dishes and their use for live cell culture monitoring. The impact of the PRP on the light budget is discussed and performances are demonstrated. First results on the application of PRM to the observation of apoptotic body internalization are reported.
format Text
id pubmed-3087587
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Optical Society of America
record_format MEDLINE/PubMed
spelling pubmed-30875872011-05-10 Position-referenced microscopy for live cell culture monitoring Galeano Z., July A. Sandoz, Patrick Gaiffe, Emilie Launay, Sophie Robert, Laurent Jacquot, Maxime Hirchaud, Fabienne Prétet, Jean-Luc Mougin, Christiane Biomed Opt Express Cell Studies Position-referenced microscopy (PRM) is based on smart sample holders that integrate a position reference pattern (PRP) in their depth, allowing the determination of the lateral coordinates with respect to the sample-holder itself. Regions of interest can thus be retrieved easily after culture dish transfers from a cell incubator to the microscope stage. Images recorded at different instants in time are superimposed in a common coordinate system with subpixel accuracy. This paper presents such smart Petri culture dishes and their use for live cell culture monitoring. The impact of the PRP on the light budget is discussed and performances are demonstrated. First results on the application of PRM to the observation of apoptotic body internalization are reported. Optical Society of America 2011-04-25 /pmc/articles/PMC3087587/ /pubmed/21559142 http://dx.doi.org/10.1364/BOE.2.001307 Text en ©2011 Optical Society of America http://creativecommons.org/licenses/by-nc-nd/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-No Derivative Works 3.0 Unported License, which permits download and redistribution, provided that the original work is properly cited. This license restricts the article from being modified or used commercially.
spellingShingle Cell Studies
Galeano Z., July A.
Sandoz, Patrick
Gaiffe, Emilie
Launay, Sophie
Robert, Laurent
Jacquot, Maxime
Hirchaud, Fabienne
Prétet, Jean-Luc
Mougin, Christiane
Position-referenced microscopy for live cell culture monitoring
title Position-referenced microscopy for live cell culture monitoring
title_full Position-referenced microscopy for live cell culture monitoring
title_fullStr Position-referenced microscopy for live cell culture monitoring
title_full_unstemmed Position-referenced microscopy for live cell culture monitoring
title_short Position-referenced microscopy for live cell culture monitoring
title_sort position-referenced microscopy for live cell culture monitoring
topic Cell Studies
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3087587/
https://www.ncbi.nlm.nih.gov/pubmed/21559142
http://dx.doi.org/10.1364/BOE.2.001307
work_keys_str_mv AT galeanozjulya positionreferencedmicroscopyforlivecellculturemonitoring
AT sandozpatrick positionreferencedmicroscopyforlivecellculturemonitoring
AT gaiffeemilie positionreferencedmicroscopyforlivecellculturemonitoring
AT launaysophie positionreferencedmicroscopyforlivecellculturemonitoring
AT robertlaurent positionreferencedmicroscopyforlivecellculturemonitoring
AT jacquotmaxime positionreferencedmicroscopyforlivecellculturemonitoring
AT hirchaudfabienne positionreferencedmicroscopyforlivecellculturemonitoring
AT pretetjeanluc positionreferencedmicroscopyforlivecellculturemonitoring
AT mouginchristiane positionreferencedmicroscopyforlivecellculturemonitoring