Cargando…
The Diagnostic Accuracy, Image Quality and Radiation Dose of 64-Slice Dual-Source CT in Daily Practice: a Single Institution's Experience
OBJECTIVE: We wanted to evaluate the image quality, diagnostic accuracy and radiation exposure of 64-slice dual-source CT (DSCT) coronary angiography according to the heart rate in symptomatic patients during daily clinical practice. MATERIALS AND METHODS: We performed a retrospective search for the...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Radiology
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3088848/ https://www.ncbi.nlm.nih.gov/pubmed/21603290 http://dx.doi.org/10.3348/kjr.2011.12.3.308 |
_version_ | 1782202941450485760 |
---|---|
author | Moon, Joon Ho Park, Eun-Ah Lee, Whal Yin, Yong Hu Chung, Jin Wook Park, Jae Hyung Lee, Hae-Young Kang, Hyun-Jae Kim, Hyo-Soo |
author_facet | Moon, Joon Ho Park, Eun-Ah Lee, Whal Yin, Yong Hu Chung, Jin Wook Park, Jae Hyung Lee, Hae-Young Kang, Hyun-Jae Kim, Hyo-Soo |
author_sort | Moon, Joon Ho |
collection | PubMed |
description | OBJECTIVE: We wanted to evaluate the image quality, diagnostic accuracy and radiation exposure of 64-slice dual-source CT (DSCT) coronary angiography according to the heart rate in symptomatic patients during daily clinical practice. MATERIALS AND METHODS: We performed a retrospective search for the DSCT coronary angiography reports of 729 consecutive symptomatic patients. For the 131 patients who underwent invasive coronary angiography, the image quality, the diagnostic performance (sensitivity, specificity, positive predictive value [PPV] and negative predictive value [NPV] for detecting significant stenosis ≥ 50% diameter) and the radiation exposure were evaluated. These values were compared between the groups with differing heart rates (HR): mean HR < 65 or ≥ 65 and HR variability (HRV) < 15 or ≥ 15. RESULTS: Among the 729 patients, the CT reports showed no stenosis or insignificant coronary artery stenosis in 72%, significant stenosis in 26% and non-diagnostic in 2%. For the 131 patients who underwent invasive coronary angiography, 95% of the patients and 97% of the segments were evaluable, and the overall per-patient/per-segment sensitivity, the perpatient/per-segment specificity, the per-patient/per-segment PPV and the per-patient/per-segment NPV were 100%/90%, 71%/98%, 95%/88% and 100%/97%, respectively. The image quality was better in the HR < 65 group than in the HR ≥ 65 group (p = 0.001), but there was no difference in diagnostic performance between the two groups. The mean effective radiation doses were lower in the HR < 65 or HRV < 15 group (p < 0.0001): 5.5 versus 6.7 mSv for the mean HR groups and 5.3 versus 9.3 mSv for the HRV groups. CONCLUSION: Dual-source CT coronary angiography is a highly accurate modality in the clinical setting. Better image quality and a significant radiation reduction are being rendered in the lower HR group. |
format | Text |
id | pubmed-3088848 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | The Korean Society of Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-30888482011-05-19 The Diagnostic Accuracy, Image Quality and Radiation Dose of 64-Slice Dual-Source CT in Daily Practice: a Single Institution's Experience Moon, Joon Ho Park, Eun-Ah Lee, Whal Yin, Yong Hu Chung, Jin Wook Park, Jae Hyung Lee, Hae-Young Kang, Hyun-Jae Kim, Hyo-Soo Korean J Radiol Original Article OBJECTIVE: We wanted to evaluate the image quality, diagnostic accuracy and radiation exposure of 64-slice dual-source CT (DSCT) coronary angiography according to the heart rate in symptomatic patients during daily clinical practice. MATERIALS AND METHODS: We performed a retrospective search for the DSCT coronary angiography reports of 729 consecutive symptomatic patients. For the 131 patients who underwent invasive coronary angiography, the image quality, the diagnostic performance (sensitivity, specificity, positive predictive value [PPV] and negative predictive value [NPV] for detecting significant stenosis ≥ 50% diameter) and the radiation exposure were evaluated. These values were compared between the groups with differing heart rates (HR): mean HR < 65 or ≥ 65 and HR variability (HRV) < 15 or ≥ 15. RESULTS: Among the 729 patients, the CT reports showed no stenosis or insignificant coronary artery stenosis in 72%, significant stenosis in 26% and non-diagnostic in 2%. For the 131 patients who underwent invasive coronary angiography, 95% of the patients and 97% of the segments were evaluable, and the overall per-patient/per-segment sensitivity, the perpatient/per-segment specificity, the per-patient/per-segment PPV and the per-patient/per-segment NPV were 100%/90%, 71%/98%, 95%/88% and 100%/97%, respectively. The image quality was better in the HR < 65 group than in the HR ≥ 65 group (p = 0.001), but there was no difference in diagnostic performance between the two groups. The mean effective radiation doses were lower in the HR < 65 or HRV < 15 group (p < 0.0001): 5.5 versus 6.7 mSv for the mean HR groups and 5.3 versus 9.3 mSv for the HRV groups. CONCLUSION: Dual-source CT coronary angiography is a highly accurate modality in the clinical setting. Better image quality and a significant radiation reduction are being rendered in the lower HR group. The Korean Society of Radiology 2011 2011-04-25 /pmc/articles/PMC3088848/ /pubmed/21603290 http://dx.doi.org/10.3348/kjr.2011.12.3.308 Text en Copyright © 2011 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Moon, Joon Ho Park, Eun-Ah Lee, Whal Yin, Yong Hu Chung, Jin Wook Park, Jae Hyung Lee, Hae-Young Kang, Hyun-Jae Kim, Hyo-Soo The Diagnostic Accuracy, Image Quality and Radiation Dose of 64-Slice Dual-Source CT in Daily Practice: a Single Institution's Experience |
title | The Diagnostic Accuracy, Image Quality and Radiation Dose of 64-Slice Dual-Source CT in Daily Practice: a Single Institution's Experience |
title_full | The Diagnostic Accuracy, Image Quality and Radiation Dose of 64-Slice Dual-Source CT in Daily Practice: a Single Institution's Experience |
title_fullStr | The Diagnostic Accuracy, Image Quality and Radiation Dose of 64-Slice Dual-Source CT in Daily Practice: a Single Institution's Experience |
title_full_unstemmed | The Diagnostic Accuracy, Image Quality and Radiation Dose of 64-Slice Dual-Source CT in Daily Practice: a Single Institution's Experience |
title_short | The Diagnostic Accuracy, Image Quality and Radiation Dose of 64-Slice Dual-Source CT in Daily Practice: a Single Institution's Experience |
title_sort | diagnostic accuracy, image quality and radiation dose of 64-slice dual-source ct in daily practice: a single institution's experience |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3088848/ https://www.ncbi.nlm.nih.gov/pubmed/21603290 http://dx.doi.org/10.3348/kjr.2011.12.3.308 |
work_keys_str_mv | AT moonjoonho thediagnosticaccuracyimagequalityandradiationdoseof64slicedualsourcectindailypracticeasingleinstitutionsexperience AT parkeunah thediagnosticaccuracyimagequalityandradiationdoseof64slicedualsourcectindailypracticeasingleinstitutionsexperience AT leewhal thediagnosticaccuracyimagequalityandradiationdoseof64slicedualsourcectindailypracticeasingleinstitutionsexperience AT yinyonghu thediagnosticaccuracyimagequalityandradiationdoseof64slicedualsourcectindailypracticeasingleinstitutionsexperience AT chungjinwook thediagnosticaccuracyimagequalityandradiationdoseof64slicedualsourcectindailypracticeasingleinstitutionsexperience AT parkjaehyung thediagnosticaccuracyimagequalityandradiationdoseof64slicedualsourcectindailypracticeasingleinstitutionsexperience AT leehaeyoung thediagnosticaccuracyimagequalityandradiationdoseof64slicedualsourcectindailypracticeasingleinstitutionsexperience AT kanghyunjae thediagnosticaccuracyimagequalityandradiationdoseof64slicedualsourcectindailypracticeasingleinstitutionsexperience AT kimhyosoo thediagnosticaccuracyimagequalityandradiationdoseof64slicedualsourcectindailypracticeasingleinstitutionsexperience AT moonjoonho diagnosticaccuracyimagequalityandradiationdoseof64slicedualsourcectindailypracticeasingleinstitutionsexperience AT parkeunah diagnosticaccuracyimagequalityandradiationdoseof64slicedualsourcectindailypracticeasingleinstitutionsexperience AT leewhal diagnosticaccuracyimagequalityandradiationdoseof64slicedualsourcectindailypracticeasingleinstitutionsexperience AT yinyonghu diagnosticaccuracyimagequalityandradiationdoseof64slicedualsourcectindailypracticeasingleinstitutionsexperience AT chungjinwook diagnosticaccuracyimagequalityandradiationdoseof64slicedualsourcectindailypracticeasingleinstitutionsexperience AT parkjaehyung diagnosticaccuracyimagequalityandradiationdoseof64slicedualsourcectindailypracticeasingleinstitutionsexperience AT leehaeyoung diagnosticaccuracyimagequalityandradiationdoseof64slicedualsourcectindailypracticeasingleinstitutionsexperience AT kanghyunjae diagnosticaccuracyimagequalityandradiationdoseof64slicedualsourcectindailypracticeasingleinstitutionsexperience AT kimhyosoo diagnosticaccuracyimagequalityandradiationdoseof64slicedualsourcectindailypracticeasingleinstitutionsexperience |