Cargando…

The T2-Shortening Effect of Gadolinium and the Optimal Conditions for Maximizing the CNR for Evaluating the Biliary System: a Phantom Study

OBJECTIVE: Clear depiction of the common bile duct is important when evaluating neonatal cholestasis in order to differentiate biliary atresia from other diseases. During MR cholangiopancreatography, the T2-shortening effect of gadolinium can increase the contrast-to-noise ratio (CNR) of the bile du...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Mi-Jung, Kim, Myung-Joon, Yoon, Choon-Sik, Song, Si Young, Park, Kyungsoo, Kim, Woo Sun
Formato: Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3088853/
https://www.ncbi.nlm.nih.gov/pubmed/21603295
http://dx.doi.org/10.3348/kjr.2011.12.3.358
_version_ 1782202942644813824
author Lee, Mi-Jung
Kim, Myung-Joon
Yoon, Choon-Sik
Song, Si Young
Park, Kyungsoo
Kim, Woo Sun
author_facet Lee, Mi-Jung
Kim, Myung-Joon
Yoon, Choon-Sik
Song, Si Young
Park, Kyungsoo
Kim, Woo Sun
author_sort Lee, Mi-Jung
collection PubMed
description OBJECTIVE: Clear depiction of the common bile duct is important when evaluating neonatal cholestasis in order to differentiate biliary atresia from other diseases. During MR cholangiopancreatography, the T2-shortening effect of gadolinium can increase the contrast-to-noise ratio (CNR) of the bile duct and enhance its depiction. The purpose of this study was to confirm, by performing a phantom study, the T2-shortening effect of gadolinium, to evaluate the effect of different gadolinium chelates with different gadolinium concentrations and different magnetic field strengths for investigating the optimal combination of these conditions, and for identifying the maximum CNR for the evaluation of the biliary system. MATERIALS AND METHODS: MR imaging using a T2-weighted single-shot fast spin echo sequence and T2 relaxometry was performed with a sponge phantom in a syringe tube. Two kinds of contrast agents (Gd-DTPA and Gd-EOB-DTPA) with different gadolinium concentrations were evaluated with 1.5T and 3T scanners. The signal intensities, the CNRs and the T2 relaxation time were analyzed. RESULTS: The signal intensities significantly decreased as the gadolinium concentrations increased (p < 0.001) with both contrast agents. These signal intensities were higher on a 3T (p < 0.001) scanner. The CNRs were higher on a 1.5T (p < 0.001) scanner and they showed no significant change with different gadolinium concentrations. The T2 relaxation time also showed a negative correlation with the gadolinium concentrations (p < 0.001) and the CNRs showed decrease more with Gd-EOB-DTPA (versus Gd-DTPA; p < 0.001) on a 3T scanner (versus 1.5T; p < 0.001). CONCLUSION: A T2-shortening effect of gadolinium exhibits a negative correlation with the gadolinium concentration for both the signal intensities and the T2 relaxation time. A higher CNR can be obtained with Gd-DTPA on a 1.5T MRI scanner.
format Text
id pubmed-3088853
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-30888532011-05-19 The T2-Shortening Effect of Gadolinium and the Optimal Conditions for Maximizing the CNR for Evaluating the Biliary System: a Phantom Study Lee, Mi-Jung Kim, Myung-Joon Yoon, Choon-Sik Song, Si Young Park, Kyungsoo Kim, Woo Sun Korean J Radiol Original Article OBJECTIVE: Clear depiction of the common bile duct is important when evaluating neonatal cholestasis in order to differentiate biliary atresia from other diseases. During MR cholangiopancreatography, the T2-shortening effect of gadolinium can increase the contrast-to-noise ratio (CNR) of the bile duct and enhance its depiction. The purpose of this study was to confirm, by performing a phantom study, the T2-shortening effect of gadolinium, to evaluate the effect of different gadolinium chelates with different gadolinium concentrations and different magnetic field strengths for investigating the optimal combination of these conditions, and for identifying the maximum CNR for the evaluation of the biliary system. MATERIALS AND METHODS: MR imaging using a T2-weighted single-shot fast spin echo sequence and T2 relaxometry was performed with a sponge phantom in a syringe tube. Two kinds of contrast agents (Gd-DTPA and Gd-EOB-DTPA) with different gadolinium concentrations were evaluated with 1.5T and 3T scanners. The signal intensities, the CNRs and the T2 relaxation time were analyzed. RESULTS: The signal intensities significantly decreased as the gadolinium concentrations increased (p < 0.001) with both contrast agents. These signal intensities were higher on a 3T (p < 0.001) scanner. The CNRs were higher on a 1.5T (p < 0.001) scanner and they showed no significant change with different gadolinium concentrations. The T2 relaxation time also showed a negative correlation with the gadolinium concentrations (p < 0.001) and the CNRs showed decrease more with Gd-EOB-DTPA (versus Gd-DTPA; p < 0.001) on a 3T scanner (versus 1.5T; p < 0.001). CONCLUSION: A T2-shortening effect of gadolinium exhibits a negative correlation with the gadolinium concentration for both the signal intensities and the T2 relaxation time. A higher CNR can be obtained with Gd-DTPA on a 1.5T MRI scanner. The Korean Society of Radiology 2011 2011-04-26 /pmc/articles/PMC3088853/ /pubmed/21603295 http://dx.doi.org/10.3348/kjr.2011.12.3.358 Text en Copyright © 2011 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lee, Mi-Jung
Kim, Myung-Joon
Yoon, Choon-Sik
Song, Si Young
Park, Kyungsoo
Kim, Woo Sun
The T2-Shortening Effect of Gadolinium and the Optimal Conditions for Maximizing the CNR for Evaluating the Biliary System: a Phantom Study
title The T2-Shortening Effect of Gadolinium and the Optimal Conditions for Maximizing the CNR for Evaluating the Biliary System: a Phantom Study
title_full The T2-Shortening Effect of Gadolinium and the Optimal Conditions for Maximizing the CNR for Evaluating the Biliary System: a Phantom Study
title_fullStr The T2-Shortening Effect of Gadolinium and the Optimal Conditions for Maximizing the CNR for Evaluating the Biliary System: a Phantom Study
title_full_unstemmed The T2-Shortening Effect of Gadolinium and the Optimal Conditions for Maximizing the CNR for Evaluating the Biliary System: a Phantom Study
title_short The T2-Shortening Effect of Gadolinium and the Optimal Conditions for Maximizing the CNR for Evaluating the Biliary System: a Phantom Study
title_sort t2-shortening effect of gadolinium and the optimal conditions for maximizing the cnr for evaluating the biliary system: a phantom study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3088853/
https://www.ncbi.nlm.nih.gov/pubmed/21603295
http://dx.doi.org/10.3348/kjr.2011.12.3.358
work_keys_str_mv AT leemijung thet2shorteningeffectofgadoliniumandtheoptimalconditionsformaximizingthecnrforevaluatingthebiliarysystemaphantomstudy
AT kimmyungjoon thet2shorteningeffectofgadoliniumandtheoptimalconditionsformaximizingthecnrforevaluatingthebiliarysystemaphantomstudy
AT yoonchoonsik thet2shorteningeffectofgadoliniumandtheoptimalconditionsformaximizingthecnrforevaluatingthebiliarysystemaphantomstudy
AT songsiyoung thet2shorteningeffectofgadoliniumandtheoptimalconditionsformaximizingthecnrforevaluatingthebiliarysystemaphantomstudy
AT parkkyungsoo thet2shorteningeffectofgadoliniumandtheoptimalconditionsformaximizingthecnrforevaluatingthebiliarysystemaphantomstudy
AT kimwoosun thet2shorteningeffectofgadoliniumandtheoptimalconditionsformaximizingthecnrforevaluatingthebiliarysystemaphantomstudy
AT leemijung t2shorteningeffectofgadoliniumandtheoptimalconditionsformaximizingthecnrforevaluatingthebiliarysystemaphantomstudy
AT kimmyungjoon t2shorteningeffectofgadoliniumandtheoptimalconditionsformaximizingthecnrforevaluatingthebiliarysystemaphantomstudy
AT yoonchoonsik t2shorteningeffectofgadoliniumandtheoptimalconditionsformaximizingthecnrforevaluatingthebiliarysystemaphantomstudy
AT songsiyoung t2shorteningeffectofgadoliniumandtheoptimalconditionsformaximizingthecnrforevaluatingthebiliarysystemaphantomstudy
AT parkkyungsoo t2shorteningeffectofgadoliniumandtheoptimalconditionsformaximizingthecnrforevaluatingthebiliarysystemaphantomstudy
AT kimwoosun t2shorteningeffectofgadoliniumandtheoptimalconditionsformaximizingthecnrforevaluatingthebiliarysystemaphantomstudy