Cargando…

Failed surgical ligation of the proximal left subclavian artery during hybrid thoracic endovascular aortic repair successfully managed by percutaneous plug or coil occlusion: a report of 3 cases

Open surgical rerouting and proximal ligation of one or more supra-aortic vessels prior to endovascular stent-graft placement has become an alternative to major open thoracic surgery in the treatment of complex thoracic aortic disease. Complications owing to failed surgical ligation of the left subc...

Descripción completa

Detalles Bibliográficos
Autores principales: Maleux, Geert, Vaninbroukx, Johan, Heye, Sam
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3090327/
https://www.ncbi.nlm.nih.gov/pubmed/21477301
http://dx.doi.org/10.1186/1749-8090-6-45
_version_ 1782203137258422272
author Maleux, Geert
Vaninbroukx, Johan
Heye, Sam
author_facet Maleux, Geert
Vaninbroukx, Johan
Heye, Sam
author_sort Maleux, Geert
collection PubMed
description Open surgical rerouting and proximal ligation of one or more supra-aortic vessels prior to endovascular stent-graft placement has become an alternative to major open thoracic surgery in the treatment of complex thoracic aortic disease. Complications owing to failed surgical ligation of the left subclavian artery are rare. In this report, 3 cases of failed ligation are presented. Diagnosis was made by CT-scan and treatment was performed by transcatheter coil and plug embolization, avoiding redo neck surgery.
format Text
id pubmed-3090327
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-30903272011-05-10 Failed surgical ligation of the proximal left subclavian artery during hybrid thoracic endovascular aortic repair successfully managed by percutaneous plug or coil occlusion: a report of 3 cases Maleux, Geert Vaninbroukx, Johan Heye, Sam J Cardiothorac Surg Case Report Open surgical rerouting and proximal ligation of one or more supra-aortic vessels prior to endovascular stent-graft placement has become an alternative to major open thoracic surgery in the treatment of complex thoracic aortic disease. Complications owing to failed surgical ligation of the left subclavian artery are rare. In this report, 3 cases of failed ligation are presented. Diagnosis was made by CT-scan and treatment was performed by transcatheter coil and plug embolization, avoiding redo neck surgery. BioMed Central 2011-04-08 /pmc/articles/PMC3090327/ /pubmed/21477301 http://dx.doi.org/10.1186/1749-8090-6-45 Text en Copyright ©2011 Maleux et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Maleux, Geert
Vaninbroukx, Johan
Heye, Sam
Failed surgical ligation of the proximal left subclavian artery during hybrid thoracic endovascular aortic repair successfully managed by percutaneous plug or coil occlusion: a report of 3 cases
title Failed surgical ligation of the proximal left subclavian artery during hybrid thoracic endovascular aortic repair successfully managed by percutaneous plug or coil occlusion: a report of 3 cases
title_full Failed surgical ligation of the proximal left subclavian artery during hybrid thoracic endovascular aortic repair successfully managed by percutaneous plug or coil occlusion: a report of 3 cases
title_fullStr Failed surgical ligation of the proximal left subclavian artery during hybrid thoracic endovascular aortic repair successfully managed by percutaneous plug or coil occlusion: a report of 3 cases
title_full_unstemmed Failed surgical ligation of the proximal left subclavian artery during hybrid thoracic endovascular aortic repair successfully managed by percutaneous plug or coil occlusion: a report of 3 cases
title_short Failed surgical ligation of the proximal left subclavian artery during hybrid thoracic endovascular aortic repair successfully managed by percutaneous plug or coil occlusion: a report of 3 cases
title_sort failed surgical ligation of the proximal left subclavian artery during hybrid thoracic endovascular aortic repair successfully managed by percutaneous plug or coil occlusion: a report of 3 cases
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3090327/
https://www.ncbi.nlm.nih.gov/pubmed/21477301
http://dx.doi.org/10.1186/1749-8090-6-45
work_keys_str_mv AT maleuxgeert failedsurgicalligationoftheproximalleftsubclavianarteryduringhybridthoracicendovascularaorticrepairsuccessfullymanagedbypercutaneousplugorcoilocclusionareportof3cases
AT vaninbroukxjohan failedsurgicalligationoftheproximalleftsubclavianarteryduringhybridthoracicendovascularaorticrepairsuccessfullymanagedbypercutaneousplugorcoilocclusionareportof3cases
AT heyesam failedsurgicalligationoftheproximalleftsubclavianarteryduringhybridthoracicendovascularaorticrepairsuccessfullymanagedbypercutaneousplugorcoilocclusionareportof3cases