The uncalibrated pulse contour cardiac output during off-pump coronary bypass surgery: performance in patients with a low cardiac output status and a reduced left ventricular function

BACKGROUND: We compared the continuous cardiac index measured by the FloTrac/Vigileo™ system (FCI) to that measured by a pulmonary artery catheter (CCI) with emphasis on the accuracy of the FCI in patients with a decreased left ventricular ejection fraction (LVEF) and a low cardiac output status dur...

Descripción completa

Detalles Bibliográficos
Autores principales: Jo, Youn Yi, Song, Jong Wook, Yoo, Young Chul, Park, Ji Young, Shim, Jae Kwang, Kwak, Young Lan
Formato: Texto
Lenguaje:English
Publicado: The Korean Society of Anesthesiologists 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3092957/
https://www.ncbi.nlm.nih.gov/pubmed/21602972
http://dx.doi.org/10.4097/kjae.2011.60.4.237
_version_ 1782203417973751808
author Jo, Youn Yi
Song, Jong Wook
Yoo, Young Chul
Park, Ji Young
Shim, Jae Kwang
Kwak, Young Lan
author_facet Jo, Youn Yi
Song, Jong Wook
Yoo, Young Chul
Park, Ji Young
Shim, Jae Kwang
Kwak, Young Lan
author_sort Jo, Youn Yi
collection PubMed
description BACKGROUND: We compared the continuous cardiac index measured by the FloTrac/Vigileo™ system (FCI) to that measured by a pulmonary artery catheter (CCI) with emphasis on the accuracy of the FCI in patients with a decreased left ventricular ejection fraction (LVEF) and a low cardiac output status during off-pump coronary bypass surgery (OPCAB). We also assessed the influence of several factors affecting the pulse contour, such as the mean arterial pressure (MAP), the systemic vascular resistance index (SVRI) and the use of norepinephrine. METHODS: Fifty patients who were undergoing OPCAB (30 patients with a LVEF ≥ 40%, 20 patients with a LVEF < 40%) were enrolled. The FCI and CCI were measured and we performed a Bland-Altman analysis. Subgroup analyses were done according to the LVEF (< 40%), the CCI (≤ 2.4 L/min/m), the MAP (60-80 mmHg), the SVRI (1,600-2,600 dyne/s/cm(5)/m(2)) and the use of norepinephrine. RESULTS: The FCI was reliable at all the time points of measurement with an overall bias and limit of agreement of -0.07 and 0.67 L/min/m(2), respectively, resulting in a percentage error of 26.9%. The percentage errors in the patients with a decreased LVEF and in a low cardiac output status were 28.2% and 22.3%, respectively. However, the percentage error in the 91 data pairs outside the normal range of the SVRI was 40.2%. CONCLUSIONS: The cardiac output measured by the FloTrac/Vigileo™ system was reliable even in patients with a decreased LVEF and in a low cardiac output status during OPCAB. Acceptable agreement was also noted during the period of heart displacement and grafting of the obtuse marginalis branch.
format Text
id pubmed-3092957
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher The Korean Society of Anesthesiologists
record_format MEDLINE/PubMed
spelling pubmed-30929572011-05-20 The uncalibrated pulse contour cardiac output during off-pump coronary bypass surgery: performance in patients with a low cardiac output status and a reduced left ventricular function Jo, Youn Yi Song, Jong Wook Yoo, Young Chul Park, Ji Young Shim, Jae Kwang Kwak, Young Lan Korean J Anesthesiol Clinical Research Article BACKGROUND: We compared the continuous cardiac index measured by the FloTrac/Vigileo™ system (FCI) to that measured by a pulmonary artery catheter (CCI) with emphasis on the accuracy of the FCI in patients with a decreased left ventricular ejection fraction (LVEF) and a low cardiac output status during off-pump coronary bypass surgery (OPCAB). We also assessed the influence of several factors affecting the pulse contour, such as the mean arterial pressure (MAP), the systemic vascular resistance index (SVRI) and the use of norepinephrine. METHODS: Fifty patients who were undergoing OPCAB (30 patients with a LVEF ≥ 40%, 20 patients with a LVEF < 40%) were enrolled. The FCI and CCI were measured and we performed a Bland-Altman analysis. Subgroup analyses were done according to the LVEF (< 40%), the CCI (≤ 2.4 L/min/m), the MAP (60-80 mmHg), the SVRI (1,600-2,600 dyne/s/cm(5)/m(2)) and the use of norepinephrine. RESULTS: The FCI was reliable at all the time points of measurement with an overall bias and limit of agreement of -0.07 and 0.67 L/min/m(2), respectively, resulting in a percentage error of 26.9%. The percentage errors in the patients with a decreased LVEF and in a low cardiac output status were 28.2% and 22.3%, respectively. However, the percentage error in the 91 data pairs outside the normal range of the SVRI was 40.2%. CONCLUSIONS: The cardiac output measured by the FloTrac/Vigileo™ system was reliable even in patients with a decreased LVEF and in a low cardiac output status during OPCAB. Acceptable agreement was also noted during the period of heart displacement and grafting of the obtuse marginalis branch. The Korean Society of Anesthesiologists 2011-04 2011-04-26 /pmc/articles/PMC3092957/ /pubmed/21602972 http://dx.doi.org/10.4097/kjae.2011.60.4.237 Text en Copyright © the Korean Society of Anesthesiologists, 2011 http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Research Article
Jo, Youn Yi
Song, Jong Wook
Yoo, Young Chul
Park, Ji Young
Shim, Jae Kwang
Kwak, Young Lan
The uncalibrated pulse contour cardiac output during off-pump coronary bypass surgery: performance in patients with a low cardiac output status and a reduced left ventricular function
title The uncalibrated pulse contour cardiac output during off-pump coronary bypass surgery: performance in patients with a low cardiac output status and a reduced left ventricular function
title_full The uncalibrated pulse contour cardiac output during off-pump coronary bypass surgery: performance in patients with a low cardiac output status and a reduced left ventricular function
title_fullStr The uncalibrated pulse contour cardiac output during off-pump coronary bypass surgery: performance in patients with a low cardiac output status and a reduced left ventricular function
title_full_unstemmed The uncalibrated pulse contour cardiac output during off-pump coronary bypass surgery: performance in patients with a low cardiac output status and a reduced left ventricular function
title_short The uncalibrated pulse contour cardiac output during off-pump coronary bypass surgery: performance in patients with a low cardiac output status and a reduced left ventricular function
title_sort uncalibrated pulse contour cardiac output during off-pump coronary bypass surgery: performance in patients with a low cardiac output status and a reduced left ventricular function
topic Clinical Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3092957/
https://www.ncbi.nlm.nih.gov/pubmed/21602972
http://dx.doi.org/10.4097/kjae.2011.60.4.237
work_keys_str_mv AT joyounyi theuncalibratedpulsecontourcardiacoutputduringoffpumpcoronarybypasssurgeryperformanceinpatientswithalowcardiacoutputstatusandareducedleftventricularfunction
AT songjongwook theuncalibratedpulsecontourcardiacoutputduringoffpumpcoronarybypasssurgeryperformanceinpatientswithalowcardiacoutputstatusandareducedleftventricularfunction
AT yooyoungchul theuncalibratedpulsecontourcardiacoutputduringoffpumpcoronarybypasssurgeryperformanceinpatientswithalowcardiacoutputstatusandareducedleftventricularfunction
AT parkjiyoung theuncalibratedpulsecontourcardiacoutputduringoffpumpcoronarybypasssurgeryperformanceinpatientswithalowcardiacoutputstatusandareducedleftventricularfunction
AT shimjaekwang theuncalibratedpulsecontourcardiacoutputduringoffpumpcoronarybypasssurgeryperformanceinpatientswithalowcardiacoutputstatusandareducedleftventricularfunction
AT kwakyounglan theuncalibratedpulsecontourcardiacoutputduringoffpumpcoronarybypasssurgeryperformanceinpatientswithalowcardiacoutputstatusandareducedleftventricularfunction
AT joyounyi uncalibratedpulsecontourcardiacoutputduringoffpumpcoronarybypasssurgeryperformanceinpatientswithalowcardiacoutputstatusandareducedleftventricularfunction
AT songjongwook uncalibratedpulsecontourcardiacoutputduringoffpumpcoronarybypasssurgeryperformanceinpatientswithalowcardiacoutputstatusandareducedleftventricularfunction
AT yooyoungchul uncalibratedpulsecontourcardiacoutputduringoffpumpcoronarybypasssurgeryperformanceinpatientswithalowcardiacoutputstatusandareducedleftventricularfunction
AT parkjiyoung uncalibratedpulsecontourcardiacoutputduringoffpumpcoronarybypasssurgeryperformanceinpatientswithalowcardiacoutputstatusandareducedleftventricularfunction
AT shimjaekwang uncalibratedpulsecontourcardiacoutputduringoffpumpcoronarybypasssurgeryperformanceinpatientswithalowcardiacoutputstatusandareducedleftventricularfunction
AT kwakyounglan uncalibratedpulsecontourcardiacoutputduringoffpumpcoronarybypasssurgeryperformanceinpatientswithalowcardiacoutputstatusandareducedleftventricularfunction