Rapid ratiometric determination of hemoglobin concentration using UV-VIS diffuse reflectance at isosbestic wavelengths

We developed a ratiometric method capable of estimating total hemoglobin concentration from optically measured diffuse reflectance spectra. The three isosbestic wavelength ratio pairs that best correlated to total hemoglobin concentration independent of saturation and scattering were 545/390, 452/39...

Descripción completa

Detalles Bibliográficos
Autores principales: Phelps, Janelle E., Vishwanath, Karthik, Chang, Vivide T. C., Ramanujam, Nirmala
Formato: Texto
Lenguaje:English
Publicado: Optical Society of America 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3093134/
https://www.ncbi.nlm.nih.gov/pubmed/20940771
http://dx.doi.org/10.1364/OE.18.018779
_version_ 1782203439044886528
author Phelps, Janelle E.
Vishwanath, Karthik
Chang, Vivide T. C.
Ramanujam, Nirmala
author_facet Phelps, Janelle E.
Vishwanath, Karthik
Chang, Vivide T. C.
Ramanujam, Nirmala
author_sort Phelps, Janelle E.
collection PubMed
description We developed a ratiometric method capable of estimating total hemoglobin concentration from optically measured diffuse reflectance spectra. The three isosbestic wavelength ratio pairs that best correlated to total hemoglobin concentration independent of saturation and scattering were 545/390, 452/390, and 529/390 nm. These wavelength pairs were selected using forward Monte Carlo simulations which were used to extract hemoglobin concentration from experimental phantom measurements. Linear regression coefficients from the simulated data were directly applied to the phantom data, by calibrating for instrument throughput using a single phantom. Phantoms with variable scattering and hemoglobin saturation were tested with two different instruments, and the average percent errors between the expected and ratiometrically-extracted hemoglobin concentration were as low as 6.3%. A correlation of r = 0.88 between hemoglobin concentration extracted using the 529/390 nm isosbestic ratio and a scalable inverse Monte Carlo model was achieved for in vivo dysplastic cervical measurements (hemoglobin concentrations have been shown to be diagnostic for the detection of cervical pre-cancer by our group). These results indicate that use of such a simple ratiometric method has the potential to be used in clinical applications where tissue hemoglobin concentrations need to be rapidly quantified in vivo.
format Text
id pubmed-3093134
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Optical Society of America
record_format MEDLINE/PubMed
spelling pubmed-30931342011-05-12 Rapid ratiometric determination of hemoglobin concentration using UV-VIS diffuse reflectance at isosbestic wavelengths Phelps, Janelle E. Vishwanath, Karthik Chang, Vivide T. C. Ramanujam, Nirmala Opt Express Research-Article We developed a ratiometric method capable of estimating total hemoglobin concentration from optically measured diffuse reflectance spectra. The three isosbestic wavelength ratio pairs that best correlated to total hemoglobin concentration independent of saturation and scattering were 545/390, 452/390, and 529/390 nm. These wavelength pairs were selected using forward Monte Carlo simulations which were used to extract hemoglobin concentration from experimental phantom measurements. Linear regression coefficients from the simulated data were directly applied to the phantom data, by calibrating for instrument throughput using a single phantom. Phantoms with variable scattering and hemoglobin saturation were tested with two different instruments, and the average percent errors between the expected and ratiometrically-extracted hemoglobin concentration were as low as 6.3%. A correlation of r = 0.88 between hemoglobin concentration extracted using the 529/390 nm isosbestic ratio and a scalable inverse Monte Carlo model was achieved for in vivo dysplastic cervical measurements (hemoglobin concentrations have been shown to be diagnostic for the detection of cervical pre-cancer by our group). These results indicate that use of such a simple ratiometric method has the potential to be used in clinical applications where tissue hemoglobin concentrations need to be rapidly quantified in vivo. Optical Society of America 2010-08-18 /pmc/articles/PMC3093134/ /pubmed/20940771 http://dx.doi.org/10.1364/OE.18.018779 Text en ©2010 Optical Society of America http://creativecommons.org/licenses/by-nc-nd/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-No Derivative Works 3.0 Unported License, which permits download and redistribution, provided that the original work is properly cited. This license restricts the article from being modified or used commercially.
spellingShingle Research-Article
Phelps, Janelle E.
Vishwanath, Karthik
Chang, Vivide T. C.
Ramanujam, Nirmala
Rapid ratiometric determination of hemoglobin concentration using UV-VIS diffuse reflectance at isosbestic wavelengths
title Rapid ratiometric determination of hemoglobin concentration using UV-VIS diffuse reflectance at isosbestic wavelengths
title_full Rapid ratiometric determination of hemoglobin concentration using UV-VIS diffuse reflectance at isosbestic wavelengths
title_fullStr Rapid ratiometric determination of hemoglobin concentration using UV-VIS diffuse reflectance at isosbestic wavelengths
title_full_unstemmed Rapid ratiometric determination of hemoglobin concentration using UV-VIS diffuse reflectance at isosbestic wavelengths
title_short Rapid ratiometric determination of hemoglobin concentration using UV-VIS diffuse reflectance at isosbestic wavelengths
title_sort rapid ratiometric determination of hemoglobin concentration using uv-vis diffuse reflectance at isosbestic wavelengths
topic Research-Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3093134/
https://www.ncbi.nlm.nih.gov/pubmed/20940771
http://dx.doi.org/10.1364/OE.18.018779
work_keys_str_mv AT phelpsjanellee rapidratiometricdeterminationofhemoglobinconcentrationusinguvvisdiffusereflectanceatisosbesticwavelengths
AT vishwanathkarthik rapidratiometricdeterminationofhemoglobinconcentrationusinguvvisdiffusereflectanceatisosbesticwavelengths
AT changvividetc rapidratiometricdeterminationofhemoglobinconcentrationusinguvvisdiffusereflectanceatisosbesticwavelengths
AT ramanujamnirmala rapidratiometricdeterminationofhemoglobinconcentrationusinguvvisdiffusereflectanceatisosbesticwavelengths