Capsule Endoscopy in Patients with Cardiac Pacemakers, Implantable Cardioverter Defibrillators, and Left Heart Devices: A Review of the Current Literature
Background and Study Aims. Capsule endoscopy is an established tool for investigation of the small intestine. Because of limited clinical experience in patients with cardiac devices, the Food and Drug Administration and the manufacturer recommended not to use capsule endoscopy in these patients. The...
Autores principales: | , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3095403/ https://www.ncbi.nlm.nih.gov/pubmed/21603020 http://dx.doi.org/10.1155/2011/376053 |
_version_ | 1782203647404277760 |
---|---|
author | Bandorski, Dirk Keuchel, Martin Brück, Martin Hoeltgen, Reinhard Wieczorek, Marcus Jakobs, Ralf |
author_facet | Bandorski, Dirk Keuchel, Martin Brück, Martin Hoeltgen, Reinhard Wieczorek, Marcus Jakobs, Ralf |
author_sort | Bandorski, Dirk |
collection | PubMed |
description | Background and Study Aims. Capsule endoscopy is an established tool for investigation of the small intestine. Because of limited clinical experience in patients with cardiac devices, the Food and Drug Administration and the manufacturer recommended not to use capsule endoscopy in these patients. The vast majority of investigations did not reveal any interference between capsule endoscopy and cardiac devices. Methods. Studies investigating interference between CE and cardiac devices were analysed. For the review we considered studies published in English or German and indexed in Medline, as well as highly relevant abstracts. Results. In vitro and in vivo studies mainly revealed no interference between capsule endoscopy and cardiac devices. Technical data of capsule endoscopy (Given Imaging) reveal that interference with cardiac pacemakers and implantable cardioverter defibrillator is impossible. Telemetry can interfere with CE video. Conclusion. The clinical use of capsule endoscopy (Given Imaging) is unproblematic in patients with cardiac pacemakers. |
format | Text |
id | pubmed-3095403 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-30954032011-05-20 Capsule Endoscopy in Patients with Cardiac Pacemakers, Implantable Cardioverter Defibrillators, and Left Heart Devices: A Review of the Current Literature Bandorski, Dirk Keuchel, Martin Brück, Martin Hoeltgen, Reinhard Wieczorek, Marcus Jakobs, Ralf Diagn Ther Endosc Review Article Background and Study Aims. Capsule endoscopy is an established tool for investigation of the small intestine. Because of limited clinical experience in patients with cardiac devices, the Food and Drug Administration and the manufacturer recommended not to use capsule endoscopy in these patients. The vast majority of investigations did not reveal any interference between capsule endoscopy and cardiac devices. Methods. Studies investigating interference between CE and cardiac devices were analysed. For the review we considered studies published in English or German and indexed in Medline, as well as highly relevant abstracts. Results. In vitro and in vivo studies mainly revealed no interference between capsule endoscopy and cardiac devices. Technical data of capsule endoscopy (Given Imaging) reveal that interference with cardiac pacemakers and implantable cardioverter defibrillator is impossible. Telemetry can interfere with CE video. Conclusion. The clinical use of capsule endoscopy (Given Imaging) is unproblematic in patients with cardiac pacemakers. Hindawi Publishing Corporation 2011 2011-04-27 /pmc/articles/PMC3095403/ /pubmed/21603020 http://dx.doi.org/10.1155/2011/376053 Text en Copyright © 2011 Dirk Bandorski et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Review Article Bandorski, Dirk Keuchel, Martin Brück, Martin Hoeltgen, Reinhard Wieczorek, Marcus Jakobs, Ralf Capsule Endoscopy in Patients with Cardiac Pacemakers, Implantable Cardioverter Defibrillators, and Left Heart Devices: A Review of the Current Literature |
title | Capsule Endoscopy in Patients with Cardiac Pacemakers, Implantable Cardioverter Defibrillators, and Left Heart Devices: A Review of the Current Literature |
title_full | Capsule Endoscopy in Patients with Cardiac Pacemakers, Implantable Cardioverter Defibrillators, and Left Heart Devices: A Review of the Current Literature |
title_fullStr | Capsule Endoscopy in Patients with Cardiac Pacemakers, Implantable Cardioverter Defibrillators, and Left Heart Devices: A Review of the Current Literature |
title_full_unstemmed | Capsule Endoscopy in Patients with Cardiac Pacemakers, Implantable Cardioverter Defibrillators, and Left Heart Devices: A Review of the Current Literature |
title_short | Capsule Endoscopy in Patients with Cardiac Pacemakers, Implantable Cardioverter Defibrillators, and Left Heart Devices: A Review of the Current Literature |
title_sort | capsule endoscopy in patients with cardiac pacemakers, implantable cardioverter defibrillators, and left heart devices: a review of the current literature |
topic | Review Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3095403/ https://www.ncbi.nlm.nih.gov/pubmed/21603020 http://dx.doi.org/10.1155/2011/376053 |
work_keys_str_mv | AT bandorskidirk capsuleendoscopyinpatientswithcardiacpacemakersimplantablecardioverterdefibrillatorsandleftheartdevicesareviewofthecurrentliterature AT keuchelmartin capsuleendoscopyinpatientswithcardiacpacemakersimplantablecardioverterdefibrillatorsandleftheartdevicesareviewofthecurrentliterature AT bruckmartin capsuleendoscopyinpatientswithcardiacpacemakersimplantablecardioverterdefibrillatorsandleftheartdevicesareviewofthecurrentliterature AT hoeltgenreinhard capsuleendoscopyinpatientswithcardiacpacemakersimplantablecardioverterdefibrillatorsandleftheartdevicesareviewofthecurrentliterature AT wieczorekmarcus capsuleendoscopyinpatientswithcardiacpacemakersimplantablecardioverterdefibrillatorsandleftheartdevicesareviewofthecurrentliterature AT jakobsralf capsuleendoscopyinpatientswithcardiacpacemakersimplantablecardioverterdefibrillatorsandleftheartdevicesareviewofthecurrentliterature |