Cargando…
Comparison of the Effectiveness of Three Methods of Recanalization in a Model of the Middle Cerebral Artery: Thrombus Aspiration via a 4F Catheter, Thrombus Aspiration via the GP Thromboaspiration Device, and Mechanical Thrombectomy Using the Solitaire Thrombectomy Device
Introduction. This paper compares different approaches to recanalization in a model of the middle cerebral artery (MCA). Methods. An occlusive thrombus (lamb's blood) was introduced into the MCA of a model of the cerebral circulation perfused with Hartmann's solution (80 pulsations/min, me...
Autores principales: | , , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
SAGE-Hindawi Access to Research
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3095900/ https://www.ncbi.nlm.nih.gov/pubmed/21603169 http://dx.doi.org/10.4061/2011/186424 |
_version_ | 1782203694086881280 |
---|---|
author | Tennuci, Christopher Pearce, Gillian Wong, Julian Nayak, Sanjeev Jones, Tom Lally, Frank Roffe, Christine |
author_facet | Tennuci, Christopher Pearce, Gillian Wong, Julian Nayak, Sanjeev Jones, Tom Lally, Frank Roffe, Christine |
author_sort | Tennuci, Christopher |
collection | PubMed |
description | Introduction. This paper compares different approaches to recanalization in a model of the middle cerebral artery (MCA). Methods. An occlusive thrombus (lamb's blood) was introduced into the MCA of a model of the cerebral circulation perfused with Hartmann's solution (80 pulsations/min, mean pressure 90 mm Hg). Three methods of clot retrieval were tested: thrombus aspiration via a 4F catheter (n = 26), thrombus aspiration via the GP thrombus aspiration device (GPTAD) (n = 30), and mechanical thrombectomy via the Solitaire Device (n = 30). Results. Recanalization rate was similar for all 3 approaches (62%, 77%, and 85%). Time to recanalization was faster with aspiration devices (41 SD 42 s for 4F and 61 SD 21 s for GPTAD) than with the Solitaire (197 SD 64 s P < .05 Kruksal-Wallis). Clot fragmentation was the same in the Solitaire (23%) and the GPTAD (23%), but higher with the 4F (53%, P < .05). Conclusion. In this model, thrombus aspiration was faster than mechanical thrombectomy, and similarly effective at recanalization. These results should be confirmed in vivo. |
format | Text |
id | pubmed-3095900 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | SAGE-Hindawi Access to Research |
record_format | MEDLINE/PubMed |
spelling | pubmed-30959002011-05-20 Comparison of the Effectiveness of Three Methods of Recanalization in a Model of the Middle Cerebral Artery: Thrombus Aspiration via a 4F Catheter, Thrombus Aspiration via the GP Thromboaspiration Device, and Mechanical Thrombectomy Using the Solitaire Thrombectomy Device Tennuci, Christopher Pearce, Gillian Wong, Julian Nayak, Sanjeev Jones, Tom Lally, Frank Roffe, Christine Stroke Res Treat Research Article Introduction. This paper compares different approaches to recanalization in a model of the middle cerebral artery (MCA). Methods. An occlusive thrombus (lamb's blood) was introduced into the MCA of a model of the cerebral circulation perfused with Hartmann's solution (80 pulsations/min, mean pressure 90 mm Hg). Three methods of clot retrieval were tested: thrombus aspiration via a 4F catheter (n = 26), thrombus aspiration via the GP thrombus aspiration device (GPTAD) (n = 30), and mechanical thrombectomy via the Solitaire Device (n = 30). Results. Recanalization rate was similar for all 3 approaches (62%, 77%, and 85%). Time to recanalization was faster with aspiration devices (41 SD 42 s for 4F and 61 SD 21 s for GPTAD) than with the Solitaire (197 SD 64 s P < .05 Kruksal-Wallis). Clot fragmentation was the same in the Solitaire (23%) and the GPTAD (23%), but higher with the 4F (53%, P < .05). Conclusion. In this model, thrombus aspiration was faster than mechanical thrombectomy, and similarly effective at recanalization. These results should be confirmed in vivo. SAGE-Hindawi Access to Research 2011-04-14 /pmc/articles/PMC3095900/ /pubmed/21603169 http://dx.doi.org/10.4061/2011/186424 Text en Copyright © 2011 Christopher Tennuci et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Tennuci, Christopher Pearce, Gillian Wong, Julian Nayak, Sanjeev Jones, Tom Lally, Frank Roffe, Christine Comparison of the Effectiveness of Three Methods of Recanalization in a Model of the Middle Cerebral Artery: Thrombus Aspiration via a 4F Catheter, Thrombus Aspiration via the GP Thromboaspiration Device, and Mechanical Thrombectomy Using the Solitaire Thrombectomy Device |
title | Comparison of the Effectiveness of Three Methods of Recanalization in a Model of the Middle Cerebral Artery: Thrombus Aspiration via a 4F Catheter, Thrombus Aspiration via the GP Thromboaspiration Device, and Mechanical Thrombectomy Using the Solitaire Thrombectomy Device |
title_full | Comparison of the Effectiveness of Three Methods of Recanalization in a Model of the Middle Cerebral Artery: Thrombus Aspiration via a 4F Catheter, Thrombus Aspiration via the GP Thromboaspiration Device, and Mechanical Thrombectomy Using the Solitaire Thrombectomy Device |
title_fullStr | Comparison of the Effectiveness of Three Methods of Recanalization in a Model of the Middle Cerebral Artery: Thrombus Aspiration via a 4F Catheter, Thrombus Aspiration via the GP Thromboaspiration Device, and Mechanical Thrombectomy Using the Solitaire Thrombectomy Device |
title_full_unstemmed | Comparison of the Effectiveness of Three Methods of Recanalization in a Model of the Middle Cerebral Artery: Thrombus Aspiration via a 4F Catheter, Thrombus Aspiration via the GP Thromboaspiration Device, and Mechanical Thrombectomy Using the Solitaire Thrombectomy Device |
title_short | Comparison of the Effectiveness of Three Methods of Recanalization in a Model of the Middle Cerebral Artery: Thrombus Aspiration via a 4F Catheter, Thrombus Aspiration via the GP Thromboaspiration Device, and Mechanical Thrombectomy Using the Solitaire Thrombectomy Device |
title_sort | comparison of the effectiveness of three methods of recanalization in a model of the middle cerebral artery: thrombus aspiration via a 4f catheter, thrombus aspiration via the gp thromboaspiration device, and mechanical thrombectomy using the solitaire thrombectomy device |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3095900/ https://www.ncbi.nlm.nih.gov/pubmed/21603169 http://dx.doi.org/10.4061/2011/186424 |
work_keys_str_mv | AT tennucichristopher comparisonoftheeffectivenessofthreemethodsofrecanalizationinamodelofthemiddlecerebralarterythrombusaspirationviaa4fcatheterthrombusaspirationviathegpthromboaspirationdeviceandmechanicalthrombectomyusingthesolitairethrombectomydevice AT pearcegillian comparisonoftheeffectivenessofthreemethodsofrecanalizationinamodelofthemiddlecerebralarterythrombusaspirationviaa4fcatheterthrombusaspirationviathegpthromboaspirationdeviceandmechanicalthrombectomyusingthesolitairethrombectomydevice AT wongjulian comparisonoftheeffectivenessofthreemethodsofrecanalizationinamodelofthemiddlecerebralarterythrombusaspirationviaa4fcatheterthrombusaspirationviathegpthromboaspirationdeviceandmechanicalthrombectomyusingthesolitairethrombectomydevice AT nayaksanjeev comparisonoftheeffectivenessofthreemethodsofrecanalizationinamodelofthemiddlecerebralarterythrombusaspirationviaa4fcatheterthrombusaspirationviathegpthromboaspirationdeviceandmechanicalthrombectomyusingthesolitairethrombectomydevice AT jonestom comparisonoftheeffectivenessofthreemethodsofrecanalizationinamodelofthemiddlecerebralarterythrombusaspirationviaa4fcatheterthrombusaspirationviathegpthromboaspirationdeviceandmechanicalthrombectomyusingthesolitairethrombectomydevice AT lallyfrank comparisonoftheeffectivenessofthreemethodsofrecanalizationinamodelofthemiddlecerebralarterythrombusaspirationviaa4fcatheterthrombusaspirationviathegpthromboaspirationdeviceandmechanicalthrombectomyusingthesolitairethrombectomydevice AT roffechristine comparisonoftheeffectivenessofthreemethodsofrecanalizationinamodelofthemiddlecerebralarterythrombusaspirationviaa4fcatheterthrombusaspirationviathegpthromboaspirationdeviceandmechanicalthrombectomyusingthesolitairethrombectomydevice |