Was the Scanner Calibration Slide used for its intended purpose?

In the article, Scanner calibration revisited, BMC Bioinformatics 2010, 11:361, Dr. Pozhitkov used the Scanner Calibration Slide, a key product of Full Moon BioSystems to generate data in his study of microarray scanner PMT response and proposed a mathematic model for PMT response [1]. In the end, t...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Shannon, Zong, Yaping
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3096983/
https://www.ncbi.nlm.nih.gov/pubmed/21510874
http://dx.doi.org/10.1186/1471-2105-12-110
_version_ 1782203776215547904
author Zhang, Shannon
Zong, Yaping
author_facet Zhang, Shannon
Zong, Yaping
author_sort Zhang, Shannon
collection PubMed
description In the article, Scanner calibration revisited, BMC Bioinformatics 2010, 11:361, Dr. Pozhitkov used the Scanner Calibration Slide, a key product of Full Moon BioSystems to generate data in his study of microarray scanner PMT response and proposed a mathematic model for PMT response [1]. In the end, the author concluded that "Full Moon BioSystems calibration slides are inadequate for performing calibration," and recommended "against using these slides." We found these conclusions are seriously flawed and misleading, and his recommendation against using the Scanner Calibration Slide was not properly supported.
format Text
id pubmed-3096983
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-30969832011-05-19 Was the Scanner Calibration Slide used for its intended purpose? Zhang, Shannon Zong, Yaping BMC Bioinformatics Correspondence In the article, Scanner calibration revisited, BMC Bioinformatics 2010, 11:361, Dr. Pozhitkov used the Scanner Calibration Slide, a key product of Full Moon BioSystems to generate data in his study of microarray scanner PMT response and proposed a mathematic model for PMT response [1]. In the end, the author concluded that "Full Moon BioSystems calibration slides are inadequate for performing calibration," and recommended "against using these slides." We found these conclusions are seriously flawed and misleading, and his recommendation against using the Scanner Calibration Slide was not properly supported. BioMed Central 2011-04-21 /pmc/articles/PMC3096983/ /pubmed/21510874 http://dx.doi.org/10.1186/1471-2105-12-110 Text en Copyright ©2011 Zhang and Zong; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Correspondence
Zhang, Shannon
Zong, Yaping
Was the Scanner Calibration Slide used for its intended purpose?
title Was the Scanner Calibration Slide used for its intended purpose?
title_full Was the Scanner Calibration Slide used for its intended purpose?
title_fullStr Was the Scanner Calibration Slide used for its intended purpose?
title_full_unstemmed Was the Scanner Calibration Slide used for its intended purpose?
title_short Was the Scanner Calibration Slide used for its intended purpose?
title_sort was the scanner calibration slide used for its intended purpose?
topic Correspondence
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3096983/
https://www.ncbi.nlm.nih.gov/pubmed/21510874
http://dx.doi.org/10.1186/1471-2105-12-110
work_keys_str_mv AT zhangshannon wasthescannercalibrationslideusedforitsintendedpurpose
AT zongyaping wasthescannercalibrationslideusedforitsintendedpurpose