Cargando…

A new portable monitor for measuring odorous compounds in oral, exhaled and nasal air

BACKGROUND: The B/B Checker(®), a new portable device for detecting odorous compounds in oral, exhaled, and nasal air, is now available. As a single unit, this device is capable of detecting several kinds of gases mixed with volatile sulfur compounds (VSC) in addition to other odorous gasses. The pu...

Descripción completa

Detalles Bibliográficos
Autores principales: Tamaki, Naofumi, Kasuyama, Kenta, Esaki, Mitsue, Toshikawa, Takara, Honda, Shun-Ichi, Ekuni, Daisuke, Tomofuji, Takaaki, Morita, Manabu
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3097012/
https://www.ncbi.nlm.nih.gov/pubmed/21504624
http://dx.doi.org/10.1186/1472-6831-11-15
_version_ 1782203781631442944
author Tamaki, Naofumi
Kasuyama, Kenta
Esaki, Mitsue
Toshikawa, Takara
Honda, Shun-Ichi
Ekuni, Daisuke
Tomofuji, Takaaki
Morita, Manabu
author_facet Tamaki, Naofumi
Kasuyama, Kenta
Esaki, Mitsue
Toshikawa, Takara
Honda, Shun-Ichi
Ekuni, Daisuke
Tomofuji, Takaaki
Morita, Manabu
author_sort Tamaki, Naofumi
collection PubMed
description BACKGROUND: The B/B Checker(®), a new portable device for detecting odorous compounds in oral, exhaled, and nasal air, is now available. As a single unit, this device is capable of detecting several kinds of gases mixed with volatile sulfur compounds (VSC) in addition to other odorous gasses. The purpose of the present study was to evaluate the effectiveness of the B/B Checker(® )for detecting the malodor level of oral, exhaled, and nasal air. METHODS: A total of 30 healthy, non-smoking volunteers (16 males and 14 females) participated in this study. The malodor levels in oral, exhaled, and nasal air were measured using the B/B Checker(® )and by organoleptic test (OT) scores. The VSCs in each air were also measured by gas chromatography (GC). Associations among B/B Checker(® )measurements, OT scores and VSC levels were analyzed using Spearman correlation coefficients. In order to determine the appropriate B/B Checker(® )level for screening subjects with malodor, sensitivity and specificity were calculated using OT scores as an identifier for diagnosing oral malodor. RESULTS: In oral and nasal air, the total VSC levels measured by GC significantly correlated to that measured by the B/B Checker(®). Significant correlation was observed between the results of OT scores and the B/B Checker(® )measurements in oral (r = 0.892, p < 0.001), exhaled (r = 0.748, p < 0.001) and nasal air (r = 0.534, p < 0.001). The correlation between the OT scores and VSC levels was significant only for oral air (r = 0.790, p < 0.001) and nasal air (r = 0.431, p = 0.002); not for exhaled air (r = 0.310, p = 0.096). When the screening level of the B/B Checker(® )was set to 50.0 for oral air, the sensitivity and specificity were 1.00 and 0.90, respectively. On the other hand, the screening level of the B/B Checker(® )was set to 60.0 for exhaled air, the sensitivity and specificity were 0.82 and 1.00, respectively. CONCLUSION: The B/B Checker(® )is useful for objective evaluation of malodor in oral, exhaled and nasal air and for screening subjects with halitosis. TRIAL REGISTRATION: ClinicalTrials.gov: NCT01139073
format Text
id pubmed-3097012
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-30970122011-05-19 A new portable monitor for measuring odorous compounds in oral, exhaled and nasal air Tamaki, Naofumi Kasuyama, Kenta Esaki, Mitsue Toshikawa, Takara Honda, Shun-Ichi Ekuni, Daisuke Tomofuji, Takaaki Morita, Manabu BMC Oral Health Technical Advance BACKGROUND: The B/B Checker(®), a new portable device for detecting odorous compounds in oral, exhaled, and nasal air, is now available. As a single unit, this device is capable of detecting several kinds of gases mixed with volatile sulfur compounds (VSC) in addition to other odorous gasses. The purpose of the present study was to evaluate the effectiveness of the B/B Checker(® )for detecting the malodor level of oral, exhaled, and nasal air. METHODS: A total of 30 healthy, non-smoking volunteers (16 males and 14 females) participated in this study. The malodor levels in oral, exhaled, and nasal air were measured using the B/B Checker(® )and by organoleptic test (OT) scores. The VSCs in each air were also measured by gas chromatography (GC). Associations among B/B Checker(® )measurements, OT scores and VSC levels were analyzed using Spearman correlation coefficients. In order to determine the appropriate B/B Checker(® )level for screening subjects with malodor, sensitivity and specificity were calculated using OT scores as an identifier for diagnosing oral malodor. RESULTS: In oral and nasal air, the total VSC levels measured by GC significantly correlated to that measured by the B/B Checker(®). Significant correlation was observed between the results of OT scores and the B/B Checker(® )measurements in oral (r = 0.892, p < 0.001), exhaled (r = 0.748, p < 0.001) and nasal air (r = 0.534, p < 0.001). The correlation between the OT scores and VSC levels was significant only for oral air (r = 0.790, p < 0.001) and nasal air (r = 0.431, p = 0.002); not for exhaled air (r = 0.310, p = 0.096). When the screening level of the B/B Checker(® )was set to 50.0 for oral air, the sensitivity and specificity were 1.00 and 0.90, respectively. On the other hand, the screening level of the B/B Checker(® )was set to 60.0 for exhaled air, the sensitivity and specificity were 0.82 and 1.00, respectively. CONCLUSION: The B/B Checker(® )is useful for objective evaluation of malodor in oral, exhaled and nasal air and for screening subjects with halitosis. TRIAL REGISTRATION: ClinicalTrials.gov: NCT01139073 BioMed Central 2011-04-20 /pmc/articles/PMC3097012/ /pubmed/21504624 http://dx.doi.org/10.1186/1472-6831-11-15 Text en Copyright ©2011 Tamaki et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technical Advance
Tamaki, Naofumi
Kasuyama, Kenta
Esaki, Mitsue
Toshikawa, Takara
Honda, Shun-Ichi
Ekuni, Daisuke
Tomofuji, Takaaki
Morita, Manabu
A new portable monitor for measuring odorous compounds in oral, exhaled and nasal air
title A new portable monitor for measuring odorous compounds in oral, exhaled and nasal air
title_full A new portable monitor for measuring odorous compounds in oral, exhaled and nasal air
title_fullStr A new portable monitor for measuring odorous compounds in oral, exhaled and nasal air
title_full_unstemmed A new portable monitor for measuring odorous compounds in oral, exhaled and nasal air
title_short A new portable monitor for measuring odorous compounds in oral, exhaled and nasal air
title_sort new portable monitor for measuring odorous compounds in oral, exhaled and nasal air
topic Technical Advance
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3097012/
https://www.ncbi.nlm.nih.gov/pubmed/21504624
http://dx.doi.org/10.1186/1472-6831-11-15
work_keys_str_mv AT tamakinaofumi anewportablemonitorformeasuringodorouscompoundsinoralexhaledandnasalair
AT kasuyamakenta anewportablemonitorformeasuringodorouscompoundsinoralexhaledandnasalair
AT esakimitsue anewportablemonitorformeasuringodorouscompoundsinoralexhaledandnasalair
AT toshikawatakara anewportablemonitorformeasuringodorouscompoundsinoralexhaledandnasalair
AT hondashunichi anewportablemonitorformeasuringodorouscompoundsinoralexhaledandnasalair
AT ekunidaisuke anewportablemonitorformeasuringodorouscompoundsinoralexhaledandnasalair
AT tomofujitakaaki anewportablemonitorformeasuringodorouscompoundsinoralexhaledandnasalair
AT moritamanabu anewportablemonitorformeasuringodorouscompoundsinoralexhaledandnasalair
AT tamakinaofumi newportablemonitorformeasuringodorouscompoundsinoralexhaledandnasalair
AT kasuyamakenta newportablemonitorformeasuringodorouscompoundsinoralexhaledandnasalair
AT esakimitsue newportablemonitorformeasuringodorouscompoundsinoralexhaledandnasalair
AT toshikawatakara newportablemonitorformeasuringodorouscompoundsinoralexhaledandnasalair
AT hondashunichi newportablemonitorformeasuringodorouscompoundsinoralexhaledandnasalair
AT ekunidaisuke newportablemonitorformeasuringodorouscompoundsinoralexhaledandnasalair
AT tomofujitakaaki newportablemonitorformeasuringodorouscompoundsinoralexhaledandnasalair
AT moritamanabu newportablemonitorformeasuringodorouscompoundsinoralexhaledandnasalair