Improved fracture detection using the mammographic film-screen combination

AIM: The single emulsion or single screen system is usually reserved for mammography since its use in general radiography is limited. The purpose of this study is to compare the mammographic film-screen combination (MFC) and the standard film-screen combination (SFC) in terms of fracture and soft ti...

Descripción completa

Detalles Bibliográficos
Autores principales: Faridah, Y, Abdullah, BJJ, Ng, KH
Formato: Texto
Lenguaje:English
Publicado: Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, Malaysia 2005
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3097594/
https://www.ncbi.nlm.nih.gov/pubmed/21625275
http://dx.doi.org/10.2349/biij.1.1.e3
_version_ 1782203846083215360
author Faridah, Y
Abdullah, BJJ
Ng, KH
author_facet Faridah, Y
Abdullah, BJJ
Ng, KH
author_sort Faridah, Y
collection PubMed
description AIM: The single emulsion or single screen system is usually reserved for mammography since its use in general radiography is limited. The purpose of this study is to compare the mammographic film-screen combination (MFC) and the standard film-screen combination (SFC) in terms of fracture and soft tissue injuries detection. PATIENTS, METHODS AND MATERIALS: In this prospective study, 41 patients from Accident and Emergency suspected of having injury in the hands, wrists, ankles and feet regions were radiographed using both MFC and SFC. These were compared in terms of image quality, presence of fractures and soft tissue injuries. The two different film-screen combinations were also compared in terms of detection of bony fragments, film characteristics such as film speed, contrast and spatial resolution, dose and cost. RESULTS: The MFC gives statistically better image quality compared to SFC. In 10% of patients, fractures were detected only in the MFC, which also detects tiny bone fragments that may not be resolved by the SFC. The spatial resolution of the MFC is greater than the SFC. The film speed and contrast of the MFC are lower than that of the SFC. The doses of MFC were higher compared to SFC. CONCLUSIONS: The MFC detects fractures better compared with SFC. However, the entrance skin dose for the mammographic film-screen combination was about 35% to 55% higher than the standard film-screen combination.
format Text
id pubmed-3097594
institution National Center for Biotechnology Information
language English
publishDate 2005
publisher Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, Malaysia
record_format MEDLINE/PubMed
spelling pubmed-30975942011-05-24 Improved fracture detection using the mammographic film-screen combination Faridah, Y Abdullah, BJJ Ng, KH Biomed Imaging Interv J Original Article AIM: The single emulsion or single screen system is usually reserved for mammography since its use in general radiography is limited. The purpose of this study is to compare the mammographic film-screen combination (MFC) and the standard film-screen combination (SFC) in terms of fracture and soft tissue injuries detection. PATIENTS, METHODS AND MATERIALS: In this prospective study, 41 patients from Accident and Emergency suspected of having injury in the hands, wrists, ankles and feet regions were radiographed using both MFC and SFC. These were compared in terms of image quality, presence of fractures and soft tissue injuries. The two different film-screen combinations were also compared in terms of detection of bony fragments, film characteristics such as film speed, contrast and spatial resolution, dose and cost. RESULTS: The MFC gives statistically better image quality compared to SFC. In 10% of patients, fractures were detected only in the MFC, which also detects tiny bone fragments that may not be resolved by the SFC. The spatial resolution of the MFC is greater than the SFC. The film speed and contrast of the MFC are lower than that of the SFC. The doses of MFC were higher compared to SFC. CONCLUSIONS: The MFC detects fractures better compared with SFC. However, the entrance skin dose for the mammographic film-screen combination was about 35% to 55% higher than the standard film-screen combination. Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, Malaysia 2005-07-01 /pmc/articles/PMC3097594/ /pubmed/21625275 http://dx.doi.org/10.2349/biij.1.1.e3 Text en © 2005 Biomedical Imaging and Intervention Journal http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Faridah, Y
Abdullah, BJJ
Ng, KH
Improved fracture detection using the mammographic film-screen combination
title Improved fracture detection using the mammographic film-screen combination
title_full Improved fracture detection using the mammographic film-screen combination
title_fullStr Improved fracture detection using the mammographic film-screen combination
title_full_unstemmed Improved fracture detection using the mammographic film-screen combination
title_short Improved fracture detection using the mammographic film-screen combination
title_sort improved fracture detection using the mammographic film-screen combination
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3097594/
https://www.ncbi.nlm.nih.gov/pubmed/21625275
http://dx.doi.org/10.2349/biij.1.1.e3
work_keys_str_mv AT faridahy improvedfracturedetectionusingthemammographicfilmscreencombination
AT abdullahbjj improvedfracturedetectionusingthemammographicfilmscreencombination
AT ngkh improvedfracturedetectionusingthemammographicfilmscreencombination