Cargando…

Assessment of electrical impedance endotomography for hardware specification

PURPOSE: The purpose of the study is the quantitative assessment of Electrical Impedance Endotomography (EIE) for the specification of hardware systems. EIE is a modality of Electrical Impedance Tomography (EIT) where the electrodes are located on a probe placed in the middle of the region of intere...

Descripción completa

Detalles Bibliográficos
Autores principales: Jossinet, J, Fournier-Desseux, A, Matias, A
Formato: Texto
Lenguaje:English
Publicado: Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, Malaysia 2006
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3097623/
https://www.ncbi.nlm.nih.gov/pubmed/21614229
http://dx.doi.org/10.2349/biij.2.2.e24
_version_ 1782203853086654464
author Jossinet, J
Fournier-Desseux, A
Matias, A
author_facet Jossinet, J
Fournier-Desseux, A
Matias, A
author_sort Jossinet, J
collection PubMed
description PURPOSE: The purpose of the study is the quantitative assessment of Electrical Impedance Endotomography (EIE) for the specification of hardware systems. EIE is a modality of Electrical Impedance Tomography (EIT) where the electrodes are located on a probe placed in the middle of the region of interest. The absence of material boundary to the explored volume and the decrease in sensitivity away from the probe requires specific study. MATERIAL AND METHODS: The method is the derivation of the equation linking explored medium’s conductivity, the sensitivity distribution of the electrode patterns used for data collection and measuring system’s noise and bandwidth. The assessment of EIE was achieved by means of simulations based on realistic data of conductivity and noise level. RESULTS: The derived equation enabled the estimation of the current needed under realistic operating conditions corresponding to prostate imaging. The generalisation to other organs is straightforward. The image reconstructed from the simulated data and from bench experiments were in agreement and showed that the two selected drive patterns, fan3 and adjacent, gave images of similar quality in absence of noise and that adjacent drive requires significantly higher measurement current. CONCLUSION: The study confirmed the feasibility of EIE with achievable hardware specifications. The derived equation enabled the determination of design parameters for the specification of hardware systems corresponding to any given application. The study also showed that EIE is more appropriate for tissue characterisation than for high speed imaging.
format Text
id pubmed-3097623
institution National Center for Biotechnology Information
language English
publishDate 2006
publisher Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, Malaysia
record_format MEDLINE/PubMed
spelling pubmed-30976232011-05-24 Assessment of electrical impedance endotomography for hardware specification Jossinet, J Fournier-Desseux, A Matias, A Biomed Imaging Interv J Original Paper PURPOSE: The purpose of the study is the quantitative assessment of Electrical Impedance Endotomography (EIE) for the specification of hardware systems. EIE is a modality of Electrical Impedance Tomography (EIT) where the electrodes are located on a probe placed in the middle of the region of interest. The absence of material boundary to the explored volume and the decrease in sensitivity away from the probe requires specific study. MATERIAL AND METHODS: The method is the derivation of the equation linking explored medium’s conductivity, the sensitivity distribution of the electrode patterns used for data collection and measuring system’s noise and bandwidth. The assessment of EIE was achieved by means of simulations based on realistic data of conductivity and noise level. RESULTS: The derived equation enabled the estimation of the current needed under realistic operating conditions corresponding to prostate imaging. The generalisation to other organs is straightforward. The image reconstructed from the simulated data and from bench experiments were in agreement and showed that the two selected drive patterns, fan3 and adjacent, gave images of similar quality in absence of noise and that adjacent drive requires significantly higher measurement current. CONCLUSION: The study confirmed the feasibility of EIE with achievable hardware specifications. The derived equation enabled the determination of design parameters for the specification of hardware systems corresponding to any given application. The study also showed that EIE is more appropriate for tissue characterisation than for high speed imaging. Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, Malaysia 2006-04-01 /pmc/articles/PMC3097623/ /pubmed/21614229 http://dx.doi.org/10.2349/biij.2.2.e24 Text en © 2006 Biomedical Imaging and Intervention Journal http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Paper
Jossinet, J
Fournier-Desseux, A
Matias, A
Assessment of electrical impedance endotomography for hardware specification
title Assessment of electrical impedance endotomography for hardware specification
title_full Assessment of electrical impedance endotomography for hardware specification
title_fullStr Assessment of electrical impedance endotomography for hardware specification
title_full_unstemmed Assessment of electrical impedance endotomography for hardware specification
title_short Assessment of electrical impedance endotomography for hardware specification
title_sort assessment of electrical impedance endotomography for hardware specification
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3097623/
https://www.ncbi.nlm.nih.gov/pubmed/21614229
http://dx.doi.org/10.2349/biij.2.2.e24
work_keys_str_mv AT jossinetj assessmentofelectricalimpedanceendotomographyforhardwarespecification
AT fournierdesseuxa assessmentofelectricalimpedanceendotomographyforhardwarespecification
AT matiasa assessmentofelectricalimpedanceendotomographyforhardwarespecification