Measurements of patient’s setup variation in intensity-modulated radiation therapy of head and neck cancer using electronic portal imaging device
PURPOSE: To measure the interfraction setup variation of patient undergoing intensity-modulated radiation therapy (IMRT) of head and neck cancer. The data was used to define adequate treatment CTV-to-PTV margin. MATERIALS AND METHODS: During March to September 2006, data was collected from 9 head an...
Autores principales: | , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, Malaysia
2007
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3097651/ https://www.ncbi.nlm.nih.gov/pubmed/21614263 http://dx.doi.org/10.2349/biij.3.1.e30 |
_version_ | 1782203859690586112 |
---|---|
author | Naiyanet, N Oonsiri, S Lertbutsayanukul, C Suriyapee, S |
author_facet | Naiyanet, N Oonsiri, S Lertbutsayanukul, C Suriyapee, S |
author_sort | Naiyanet, N |
collection | PubMed |
description | PURPOSE: To measure the interfraction setup variation of patient undergoing intensity-modulated radiation therapy (IMRT) of head and neck cancer. The data was used to define adequate treatment CTV-to-PTV margin. MATERIALS AND METHODS: During March to September 2006, data was collected from 9 head and neck cancer patients treated with dynamic IMRT using 6 MV X-ray beam from Varian Clinac 23EX. Weekly portal images of setup fields which were anterior-posterior and lateral portal images were acquired for each patient with an amorphous silicon EPID, Varian aS500. These images were matched with the reference image from Varian Acuity simulator using the Varis vision software (Version 7.3.10). Six anatomical landmarks were selected for comparison. The displacement of portal image from the reference image was recorded in X (Left-Right, L-R), Y (Superior-Inferior, S-I) direction for anterior field and Z (Anterior-Posterior, A-P), Y (S-I) direction for lateral field. The systematic and random error for individual and population were calculated. Then the population-based margins were obtained. RESULTS: A total of 135 images (27 simulation images and 108 portal images) and 405 match points was evaluated. The systematic error ranged from 0 to 7.5 mm and the random error ranged from 0.3 to 4.8 mm for all directions. The population-based margin ranged from 2.3 to 4.5 mm (L-R), 3.5 to 4.9 mm (S-I) for anterior field and 3.4 to 4.7 mm (A-P), 2.6 to 3.7 mm (S-I) for the lateral field. These margins were comparable to the margin that was prescribed at the King Chulalongkorn Memorial Hospital (5-10 mm) for head and neck cancer. CONCLUSION: The population-based margin is less than 5 mm, thus the margin provides sufficient coverage for all of the patients. |
format | Text |
id | pubmed-3097651 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2007 |
publisher | Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, Malaysia |
record_format | MEDLINE/PubMed |
spelling | pubmed-30976512011-05-24 Measurements of patient’s setup variation in intensity-modulated radiation therapy of head and neck cancer using electronic portal imaging device Naiyanet, N Oonsiri, S Lertbutsayanukul, C Suriyapee, S Biomed Imaging Interv J Original Article PURPOSE: To measure the interfraction setup variation of patient undergoing intensity-modulated radiation therapy (IMRT) of head and neck cancer. The data was used to define adequate treatment CTV-to-PTV margin. MATERIALS AND METHODS: During March to September 2006, data was collected from 9 head and neck cancer patients treated with dynamic IMRT using 6 MV X-ray beam from Varian Clinac 23EX. Weekly portal images of setup fields which were anterior-posterior and lateral portal images were acquired for each patient with an amorphous silicon EPID, Varian aS500. These images were matched with the reference image from Varian Acuity simulator using the Varis vision software (Version 7.3.10). Six anatomical landmarks were selected for comparison. The displacement of portal image from the reference image was recorded in X (Left-Right, L-R), Y (Superior-Inferior, S-I) direction for anterior field and Z (Anterior-Posterior, A-P), Y (S-I) direction for lateral field. The systematic and random error for individual and population were calculated. Then the population-based margins were obtained. RESULTS: A total of 135 images (27 simulation images and 108 portal images) and 405 match points was evaluated. The systematic error ranged from 0 to 7.5 mm and the random error ranged from 0.3 to 4.8 mm for all directions. The population-based margin ranged from 2.3 to 4.5 mm (L-R), 3.5 to 4.9 mm (S-I) for anterior field and 3.4 to 4.7 mm (A-P), 2.6 to 3.7 mm (S-I) for the lateral field. These margins were comparable to the margin that was prescribed at the King Chulalongkorn Memorial Hospital (5-10 mm) for head and neck cancer. CONCLUSION: The population-based margin is less than 5 mm, thus the margin provides sufficient coverage for all of the patients. Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, Malaysia 2007-01-01 /pmc/articles/PMC3097651/ /pubmed/21614263 http://dx.doi.org/10.2349/biij.3.1.e30 Text en © 2007 Biomedical Imaging and Intervention Journal http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Naiyanet, N Oonsiri, S Lertbutsayanukul, C Suriyapee, S Measurements of patient’s setup variation in intensity-modulated radiation therapy of head and neck cancer using electronic portal imaging device |
title | Measurements of patient’s setup variation in intensity-modulated radiation therapy of head and neck cancer using electronic portal imaging device |
title_full | Measurements of patient’s setup variation in intensity-modulated radiation therapy of head and neck cancer using electronic portal imaging device |
title_fullStr | Measurements of patient’s setup variation in intensity-modulated radiation therapy of head and neck cancer using electronic portal imaging device |
title_full_unstemmed | Measurements of patient’s setup variation in intensity-modulated radiation therapy of head and neck cancer using electronic portal imaging device |
title_short | Measurements of patient’s setup variation in intensity-modulated radiation therapy of head and neck cancer using electronic portal imaging device |
title_sort | measurements of patient’s setup variation in intensity-modulated radiation therapy of head and neck cancer using electronic portal imaging device |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3097651/ https://www.ncbi.nlm.nih.gov/pubmed/21614263 http://dx.doi.org/10.2349/biij.3.1.e30 |
work_keys_str_mv | AT naiyanetn measurementsofpatientssetupvariationinintensitymodulatedradiationtherapyofheadandneckcancerusingelectronicportalimagingdevice AT oonsiris measurementsofpatientssetupvariationinintensitymodulatedradiationtherapyofheadandneckcancerusingelectronicportalimagingdevice AT lertbutsayanukulc measurementsofpatientssetupvariationinintensitymodulatedradiationtherapyofheadandneckcancerusingelectronicportalimagingdevice AT suriyapees measurementsofpatientssetupvariationinintensitymodulatedradiationtherapyofheadandneckcancerusingelectronicportalimagingdevice |