Cargando…

Evaluation of dose coverage to target volume and normal tissue sparing in the adjuvant radiotherapy of gastric cancers: 3D-CRT compared with dynamic IMRT

PURPOSE: To assess the potential advantage of intensity-modulated radiotherapy (IMRT) over 3D-conformal radiotherapy (3D-CRT) planning in postoperative adjuvant radiotherapy for patients with gastric carcinoma. METHODS AND MATERIALS: In a retrospective study, for plan comparison, dose distribution w...

Descripción completa

Detalles Bibliográficos
Autores principales: Murthy, KK, Shukeili, KA, Kumar, SS, Davis, CA, Chandran, RR, Namrata, S
Formato: Texto
Lenguaje:English
Publicado: Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, Malaysia 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3097777/
https://www.ncbi.nlm.nih.gov/pubmed/21611046
http://dx.doi.org/10.2349/biij.6.3.e29
_version_ 1782203889602265088
author Murthy, KK
Shukeili, KA
Kumar, SS
Davis, CA
Chandran, RR
Namrata, S
author_facet Murthy, KK
Shukeili, KA
Kumar, SS
Davis, CA
Chandran, RR
Namrata, S
author_sort Murthy, KK
collection PubMed
description PURPOSE: To assess the potential advantage of intensity-modulated radiotherapy (IMRT) over 3D-conformal radiotherapy (3D-CRT) planning in postoperative adjuvant radiotherapy for patients with gastric carcinoma. METHODS AND MATERIALS: In a retrospective study, for plan comparison, dose distribution was recalculated in 15 patients treated with 3D-CRT on the contoured structures of same CT images using an IMRT technique. 3D-conformal plans with three fields and four-fields were compared with seven-field dynamic IMRT plans. The different plans were compared by analyzing the dose coverage of planning target volume using TV(95), D(mean), uniformity index, conformity index and homogeneity index parameters. To assess critical organ sparing, D(mean), D(max), dose to one-third and two-third volumes of the OARs and percentage of volumes receiving more than their tolerance doses were compared. RESULTS: The average dose coverage values of PTV with 3F-CRT and 4F-CRT plans were comparable, where as IMRT plans achieved better target coverage(p<0.001) with higher conformity index value of 0.81±0.07 compared to both the 3D-CRT plans. The doses to the liver and bowel reduced significantly (p<0.001) with IMRT plans compared to other 3D-CRT plans. For all OARs the percentage of volumes receiving more than their tolerance doses were reduced with the IMRT plans. CONCLUSION: This study showed that a better target coverage and significant dose reduction to OARs could be achieved with the IMRT plans. The IMRT can be preferred with caution for organ motion. The authors are currently studying organ motion in the upper abdomen to use IMRT for patient treatment.
format Text
id pubmed-3097777
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, Malaysia
record_format MEDLINE/PubMed
spelling pubmed-30977772011-05-24 Evaluation of dose coverage to target volume and normal tissue sparing in the adjuvant radiotherapy of gastric cancers: 3D-CRT compared with dynamic IMRT Murthy, KK Shukeili, KA Kumar, SS Davis, CA Chandran, RR Namrata, S Biomed Imaging Interv J Original Article PURPOSE: To assess the potential advantage of intensity-modulated radiotherapy (IMRT) over 3D-conformal radiotherapy (3D-CRT) planning in postoperative adjuvant radiotherapy for patients with gastric carcinoma. METHODS AND MATERIALS: In a retrospective study, for plan comparison, dose distribution was recalculated in 15 patients treated with 3D-CRT on the contoured structures of same CT images using an IMRT technique. 3D-conformal plans with three fields and four-fields were compared with seven-field dynamic IMRT plans. The different plans were compared by analyzing the dose coverage of planning target volume using TV(95), D(mean), uniformity index, conformity index and homogeneity index parameters. To assess critical organ sparing, D(mean), D(max), dose to one-third and two-third volumes of the OARs and percentage of volumes receiving more than their tolerance doses were compared. RESULTS: The average dose coverage values of PTV with 3F-CRT and 4F-CRT plans were comparable, where as IMRT plans achieved better target coverage(p<0.001) with higher conformity index value of 0.81±0.07 compared to both the 3D-CRT plans. The doses to the liver and bowel reduced significantly (p<0.001) with IMRT plans compared to other 3D-CRT plans. For all OARs the percentage of volumes receiving more than their tolerance doses were reduced with the IMRT plans. CONCLUSION: This study showed that a better target coverage and significant dose reduction to OARs could be achieved with the IMRT plans. The IMRT can be preferred with caution for organ motion. The authors are currently studying organ motion in the upper abdomen to use IMRT for patient treatment. Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, Malaysia 2010-07-01 /pmc/articles/PMC3097777/ /pubmed/21611046 http://dx.doi.org/10.2349/biij.6.3.e29 Text en © 2010 Biomedical Imaging and Intervention Journal http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Murthy, KK
Shukeili, KA
Kumar, SS
Davis, CA
Chandran, RR
Namrata, S
Evaluation of dose coverage to target volume and normal tissue sparing in the adjuvant radiotherapy of gastric cancers: 3D-CRT compared with dynamic IMRT
title Evaluation of dose coverage to target volume and normal tissue sparing in the adjuvant radiotherapy of gastric cancers: 3D-CRT compared with dynamic IMRT
title_full Evaluation of dose coverage to target volume and normal tissue sparing in the adjuvant radiotherapy of gastric cancers: 3D-CRT compared with dynamic IMRT
title_fullStr Evaluation of dose coverage to target volume and normal tissue sparing in the adjuvant radiotherapy of gastric cancers: 3D-CRT compared with dynamic IMRT
title_full_unstemmed Evaluation of dose coverage to target volume and normal tissue sparing in the adjuvant radiotherapy of gastric cancers: 3D-CRT compared with dynamic IMRT
title_short Evaluation of dose coverage to target volume and normal tissue sparing in the adjuvant radiotherapy of gastric cancers: 3D-CRT compared with dynamic IMRT
title_sort evaluation of dose coverage to target volume and normal tissue sparing in the adjuvant radiotherapy of gastric cancers: 3d-crt compared with dynamic imrt
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3097777/
https://www.ncbi.nlm.nih.gov/pubmed/21611046
http://dx.doi.org/10.2349/biij.6.3.e29
work_keys_str_mv AT murthykk evaluationofdosecoveragetotargetvolumeandnormaltissuesparingintheadjuvantradiotherapyofgastriccancers3dcrtcomparedwithdynamicimrt
AT shukeilika evaluationofdosecoveragetotargetvolumeandnormaltissuesparingintheadjuvantradiotherapyofgastriccancers3dcrtcomparedwithdynamicimrt
AT kumarss evaluationofdosecoveragetotargetvolumeandnormaltissuesparingintheadjuvantradiotherapyofgastriccancers3dcrtcomparedwithdynamicimrt
AT davisca evaluationofdosecoveragetotargetvolumeandnormaltissuesparingintheadjuvantradiotherapyofgastriccancers3dcrtcomparedwithdynamicimrt
AT chandranrr evaluationofdosecoveragetotargetvolumeandnormaltissuesparingintheadjuvantradiotherapyofgastriccancers3dcrtcomparedwithdynamicimrt
AT namratas evaluationofdosecoveragetotargetvolumeandnormaltissuesparingintheadjuvantradiotherapyofgastriccancers3dcrtcomparedwithdynamicimrt