Cargando…
Diagnostic image quality of hysterosalpingography: ionic versus non ionic water soluble iodinated contrast media
OBJECTIVE: To compare the diagnostic image quality between three different water soluble iodinated contrast media in hysterosalpingography (HSG). MATERIAL AND METHOD: In a prospective randomised study of 204 patients, the diagnostic quality of images obtained after hysterosalpingography were evaluat...
Autores principales: | , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, Malaysia
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3097785/ https://www.ncbi.nlm.nih.gov/pubmed/21611058 http://dx.doi.org/10.2349/biij.5.3.e29 |
Sumario: | OBJECTIVE: To compare the diagnostic image quality between three different water soluble iodinated contrast media in hysterosalpingography (HSG). MATERIAL AND METHOD: In a prospective randomised study of 204 patients, the diagnostic quality of images obtained after hysterosalpingography were evaluated using Iopramide (106 patients) and Ioxaglate (98 patients). 114 patients who had undergone HSG examination using Iodamide were analysed retrospectively. Image quality was assessed by three radiologists independently based on an objective set of criteria. The obtained results were statistically analysed using Kruskal-Wallis and Mann-Whitney U test. RESULTS: Visualisation of fimbrial rugae was significantly better with Iopramide and Ioxaglate than Iodamide. All contrast media provided acceptable diagnostic image quality with regard to uterine, fallopian tubes outline and peritoneal spill. Uterine opacification was noted to be too dense in all three contrast media and not optimal for the assessment of intrauterine pathology. Higher incidence of contrast intravasation was noted in the Iodamide group. Similarly, the numbers of patients diagnosed with bilateral blocked fallopian tubes were also higher in the Iodamide group. CONCLUSION: HSG using low osmolar contrast media (Iopramide and Ioxaglate) demonstrated diagnostic image qualities similar to HSG using conventional high osmolar contrast media (Iodamide). However, all three contrast media were found to be too dense for the detection of intrauterine pathology. Better visualisation of the fimbrial outline using Ioxaglate and Iopramide were attributed to their low contrast viscosity. The increased incidence of contrast media intravasation and bilateral tubal blockage using Iodamide are probably related to the high viscosity. |
---|