Cargando…
A computed tomography based study on rotational alignment accuracy of the femoral component in total knee arthroplasty using computer-assisted orthopaedic surgery
Rotation of the femoral component in total knee arthroplasty (TKA) is of high importance in respect of the balancing of the knee and the patellofemoral joint. Though it is shown that computer assisted surgery (CAOS) improves the anteroposterior (AP) alignment in TKA, it is still unknown whether navi...
Autores principales: | , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Springer-Verlag
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3103971/ https://www.ncbi.nlm.nih.gov/pubmed/20623282 http://dx.doi.org/10.1007/s00264-010-1082-9 |
_version_ | 1782204578057420800 |
---|---|
author | van der Linden-van der Zwaag, Henrica M. J. Bos, Janneke van der Heide, Huub J. L. Nelissen, Rob G. H. H. |
author_facet | van der Linden-van der Zwaag, Henrica M. J. Bos, Janneke van der Heide, Huub J. L. Nelissen, Rob G. H. H. |
author_sort | van der Linden-van der Zwaag, Henrica M. J. |
collection | PubMed |
description | Rotation of the femoral component in total knee arthroplasty (TKA) is of high importance in respect of the balancing of the knee and the patellofemoral joint. Though it is shown that computer assisted surgery (CAOS) improves the anteroposterior (AP) alignment in TKA, it is still unknown whether navigation helps in finding the accurate rotation or even improving rotation. Therefore the aim of our study was to evaluate the postoperative femoral component rotation on computed tomography (CT) with the intraoperative data of the navigation system. In 20 navigated TKAs the difference between the intraoperative stored rotation data of the femoral component and the postoperative rotation on CT was measured using the condylar twist angle (CTA). This is the angle between the epicondylar axis and the posterior condylar axis. Statistical analysis consisted of the intraclass correlation coefficient (ICC) and Bland-Altman plot. The mean intraoperative rotation CTA based on CAOS was 3.5° (range 2.4–8.6°). The postoperative CT scan showed a mean CTA of 4.0° (1.7–7.2). The ICC between the two observers was 0.81, and within observers this was 0.84 and 0.82, respectively. However, the ICC of the CAOS CTA versus the postoperative CT CTA was only 0.38. Though CAOS is being used for optimising the position of a TKA, this study shows that the (virtual) individual rotational position of the femoral component using a CAOS system is significantly different from the position on a postoperative CT scan. |
format | Text |
id | pubmed-3103971 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | Springer-Verlag |
record_format | MEDLINE/PubMed |
spelling | pubmed-31039712011-08-16 A computed tomography based study on rotational alignment accuracy of the femoral component in total knee arthroplasty using computer-assisted orthopaedic surgery van der Linden-van der Zwaag, Henrica M. J. Bos, Janneke van der Heide, Huub J. L. Nelissen, Rob G. H. H. Int Orthop Original Paper Rotation of the femoral component in total knee arthroplasty (TKA) is of high importance in respect of the balancing of the knee and the patellofemoral joint. Though it is shown that computer assisted surgery (CAOS) improves the anteroposterior (AP) alignment in TKA, it is still unknown whether navigation helps in finding the accurate rotation or even improving rotation. Therefore the aim of our study was to evaluate the postoperative femoral component rotation on computed tomography (CT) with the intraoperative data of the navigation system. In 20 navigated TKAs the difference between the intraoperative stored rotation data of the femoral component and the postoperative rotation on CT was measured using the condylar twist angle (CTA). This is the angle between the epicondylar axis and the posterior condylar axis. Statistical analysis consisted of the intraclass correlation coefficient (ICC) and Bland-Altman plot. The mean intraoperative rotation CTA based on CAOS was 3.5° (range 2.4–8.6°). The postoperative CT scan showed a mean CTA of 4.0° (1.7–7.2). The ICC between the two observers was 0.81, and within observers this was 0.84 and 0.82, respectively. However, the ICC of the CAOS CTA versus the postoperative CT CTA was only 0.38. Though CAOS is being used for optimising the position of a TKA, this study shows that the (virtual) individual rotational position of the femoral component using a CAOS system is significantly different from the position on a postoperative CT scan. Springer-Verlag 2010-07-11 2011-06 /pmc/articles/PMC3103971/ /pubmed/20623282 http://dx.doi.org/10.1007/s00264-010-1082-9 Text en © The Author(s) 2010 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited. |
spellingShingle | Original Paper van der Linden-van der Zwaag, Henrica M. J. Bos, Janneke van der Heide, Huub J. L. Nelissen, Rob G. H. H. A computed tomography based study on rotational alignment accuracy of the femoral component in total knee arthroplasty using computer-assisted orthopaedic surgery |
title | A computed tomography based study on rotational alignment accuracy of the femoral component in total knee arthroplasty using computer-assisted orthopaedic surgery |
title_full | A computed tomography based study on rotational alignment accuracy of the femoral component in total knee arthroplasty using computer-assisted orthopaedic surgery |
title_fullStr | A computed tomography based study on rotational alignment accuracy of the femoral component in total knee arthroplasty using computer-assisted orthopaedic surgery |
title_full_unstemmed | A computed tomography based study on rotational alignment accuracy of the femoral component in total knee arthroplasty using computer-assisted orthopaedic surgery |
title_short | A computed tomography based study on rotational alignment accuracy of the femoral component in total knee arthroplasty using computer-assisted orthopaedic surgery |
title_sort | computed tomography based study on rotational alignment accuracy of the femoral component in total knee arthroplasty using computer-assisted orthopaedic surgery |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3103971/ https://www.ncbi.nlm.nih.gov/pubmed/20623282 http://dx.doi.org/10.1007/s00264-010-1082-9 |
work_keys_str_mv | AT vanderlindenvanderzwaaghenricamj acomputedtomographybasedstudyonrotationalalignmentaccuracyofthefemoralcomponentintotalkneearthroplastyusingcomputerassistedorthopaedicsurgery AT bosjanneke acomputedtomographybasedstudyonrotationalalignmentaccuracyofthefemoralcomponentintotalkneearthroplastyusingcomputerassistedorthopaedicsurgery AT vanderheidehuubjl acomputedtomographybasedstudyonrotationalalignmentaccuracyofthefemoralcomponentintotalkneearthroplastyusingcomputerassistedorthopaedicsurgery AT nelissenrobghh acomputedtomographybasedstudyonrotationalalignmentaccuracyofthefemoralcomponentintotalkneearthroplastyusingcomputerassistedorthopaedicsurgery AT vanderlindenvanderzwaaghenricamj computedtomographybasedstudyonrotationalalignmentaccuracyofthefemoralcomponentintotalkneearthroplastyusingcomputerassistedorthopaedicsurgery AT bosjanneke computedtomographybasedstudyonrotationalalignmentaccuracyofthefemoralcomponentintotalkneearthroplastyusingcomputerassistedorthopaedicsurgery AT vanderheidehuubjl computedtomographybasedstudyonrotationalalignmentaccuracyofthefemoralcomponentintotalkneearthroplastyusingcomputerassistedorthopaedicsurgery AT nelissenrobghh computedtomographybasedstudyonrotationalalignmentaccuracyofthefemoralcomponentintotalkneearthroplastyusingcomputerassistedorthopaedicsurgery |