Cargando…

Pulsed Electromagnetic Fields in the treatment of fresh scaphoid fractures. A multicenter, prospective, double blind, placebo controlled, randomized trial

BACKGROUND: The scaphoid bone is the most commonly fractured of the carpal bones. In the Netherlands 90% of all carpal fractures is a fracture of the scaphoid bone. The scaphoid has an essential role in functionality of the wrist, acting as a pivot. Complications in healing can result in poor functi...

Descripción completa

Detalles Bibliográficos
Autores principales: Hannemann, Pascal, Göttgens, Kevin WA, van Wely, Bob J, Kolkman, Karel A, Werre, Andries J, Poeze, Martijn, Brink, Peter RG
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3107178/
https://www.ncbi.nlm.nih.gov/pubmed/21548951
http://dx.doi.org/10.1186/1471-2474-12-90
_version_ 1782205200970285056
author Hannemann, Pascal
Göttgens, Kevin WA
van Wely, Bob J
Kolkman, Karel A
Werre, Andries J
Poeze, Martijn
Brink, Peter RG
author_facet Hannemann, Pascal
Göttgens, Kevin WA
van Wely, Bob J
Kolkman, Karel A
Werre, Andries J
Poeze, Martijn
Brink, Peter RG
author_sort Hannemann, Pascal
collection PubMed
description BACKGROUND: The scaphoid bone is the most commonly fractured of the carpal bones. In the Netherlands 90% of all carpal fractures is a fracture of the scaphoid bone. The scaphoid has an essential role in functionality of the wrist, acting as a pivot. Complications in healing can result in poor functional outcome. The scaphoid fracture is a troublesome fracture and failure of treatment can result in avascular necrosis (up to 40%), non-union (5-21%) and early osteo-arthritis (up to 32%) which may seriously impair wrist function. Impaired consolidation of scaphoid fractures results in longer immobilization and more days lost at work with significant psychosocial and financial consequences. Initially Pulsed Electromagnetic Fields was used in the treatment of tibial pseudoarthrosis and non-union. More recently there is evidence that physical forces can also be used in the treatment of fresh fractures, showing accelerated healing by 30% and 71% reduction in nonunion within 12 weeks after initiation of therapy. Until now no double blind randomized, placebo controlled trial has been conducted to investigate the effect of this treatment on the healing of fresh fractures of the scaphoid. METHODS/DESIGN: This is a multi center, prospective, double blind, placebo controlled, randomized trial. Study population consists of all patients with unilateral acute scaphoid fracture. Pregnant women, patients having a life supporting implanted electronic device, patients with additional fractures of wrist, carpal or metacarpal bones and pre-existing impairment in wrist function are excluded. The scaphoid fracture is diagnosed by a combination of physical and radiographic examination (CT-scanning). Proven scaphoid fractures are treated with cast immobilization and a small Pulsed Electromagnetic Fields bone growth stimulating device placed on the cast. Half of the devices will be disabled at random in the factory. Study parameters are clinical consolidation, radiological consolidation evaluated by CT-scanning, functional status of the wrist, including assessment by means of the patient rated wrist evaluation (PRWE) questionnaire and quality of life using SF-36 health survey questionnaire. Primary endpoint is number of scaphoid unions at six weeks, secondary endpoints are time interval to clinical and radiological consolidation, number of non-unions, functional status at 52 weeks and non-adherence to the treatment protocol. TRIAL REGISTRATION: Netherlands Trial Register (NTR): NTR2064
format Online
Article
Text
id pubmed-3107178
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-31071782011-06-03 Pulsed Electromagnetic Fields in the treatment of fresh scaphoid fractures. A multicenter, prospective, double blind, placebo controlled, randomized trial Hannemann, Pascal Göttgens, Kevin WA van Wely, Bob J Kolkman, Karel A Werre, Andries J Poeze, Martijn Brink, Peter RG BMC Musculoskelet Disord Study Protocol BACKGROUND: The scaphoid bone is the most commonly fractured of the carpal bones. In the Netherlands 90% of all carpal fractures is a fracture of the scaphoid bone. The scaphoid has an essential role in functionality of the wrist, acting as a pivot. Complications in healing can result in poor functional outcome. The scaphoid fracture is a troublesome fracture and failure of treatment can result in avascular necrosis (up to 40%), non-union (5-21%) and early osteo-arthritis (up to 32%) which may seriously impair wrist function. Impaired consolidation of scaphoid fractures results in longer immobilization and more days lost at work with significant psychosocial and financial consequences. Initially Pulsed Electromagnetic Fields was used in the treatment of tibial pseudoarthrosis and non-union. More recently there is evidence that physical forces can also be used in the treatment of fresh fractures, showing accelerated healing by 30% and 71% reduction in nonunion within 12 weeks after initiation of therapy. Until now no double blind randomized, placebo controlled trial has been conducted to investigate the effect of this treatment on the healing of fresh fractures of the scaphoid. METHODS/DESIGN: This is a multi center, prospective, double blind, placebo controlled, randomized trial. Study population consists of all patients with unilateral acute scaphoid fracture. Pregnant women, patients having a life supporting implanted electronic device, patients with additional fractures of wrist, carpal or metacarpal bones and pre-existing impairment in wrist function are excluded. The scaphoid fracture is diagnosed by a combination of physical and radiographic examination (CT-scanning). Proven scaphoid fractures are treated with cast immobilization and a small Pulsed Electromagnetic Fields bone growth stimulating device placed on the cast. Half of the devices will be disabled at random in the factory. Study parameters are clinical consolidation, radiological consolidation evaluated by CT-scanning, functional status of the wrist, including assessment by means of the patient rated wrist evaluation (PRWE) questionnaire and quality of life using SF-36 health survey questionnaire. Primary endpoint is number of scaphoid unions at six weeks, secondary endpoints are time interval to clinical and radiological consolidation, number of non-unions, functional status at 52 weeks and non-adherence to the treatment protocol. TRIAL REGISTRATION: Netherlands Trial Register (NTR): NTR2064 BioMed Central 2011-05-06 /pmc/articles/PMC3107178/ /pubmed/21548951 http://dx.doi.org/10.1186/1471-2474-12-90 Text en Copyright ©2011 Hannemann et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Study Protocol
Hannemann, Pascal
Göttgens, Kevin WA
van Wely, Bob J
Kolkman, Karel A
Werre, Andries J
Poeze, Martijn
Brink, Peter RG
Pulsed Electromagnetic Fields in the treatment of fresh scaphoid fractures. A multicenter, prospective, double blind, placebo controlled, randomized trial
title Pulsed Electromagnetic Fields in the treatment of fresh scaphoid fractures. A multicenter, prospective, double blind, placebo controlled, randomized trial
title_full Pulsed Electromagnetic Fields in the treatment of fresh scaphoid fractures. A multicenter, prospective, double blind, placebo controlled, randomized trial
title_fullStr Pulsed Electromagnetic Fields in the treatment of fresh scaphoid fractures. A multicenter, prospective, double blind, placebo controlled, randomized trial
title_full_unstemmed Pulsed Electromagnetic Fields in the treatment of fresh scaphoid fractures. A multicenter, prospective, double blind, placebo controlled, randomized trial
title_short Pulsed Electromagnetic Fields in the treatment of fresh scaphoid fractures. A multicenter, prospective, double blind, placebo controlled, randomized trial
title_sort pulsed electromagnetic fields in the treatment of fresh scaphoid fractures. a multicenter, prospective, double blind, placebo controlled, randomized trial
topic Study Protocol
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3107178/
https://www.ncbi.nlm.nih.gov/pubmed/21548951
http://dx.doi.org/10.1186/1471-2474-12-90
work_keys_str_mv AT hannemannpascal pulsedelectromagneticfieldsinthetreatmentoffreshscaphoidfracturesamulticenterprospectivedoubleblindplacebocontrolledrandomizedtrial
AT gottgenskevinwa pulsedelectromagneticfieldsinthetreatmentoffreshscaphoidfracturesamulticenterprospectivedoubleblindplacebocontrolledrandomizedtrial
AT vanwelybobj pulsedelectromagneticfieldsinthetreatmentoffreshscaphoidfracturesamulticenterprospectivedoubleblindplacebocontrolledrandomizedtrial
AT kolkmankarela pulsedelectromagneticfieldsinthetreatmentoffreshscaphoidfracturesamulticenterprospectivedoubleblindplacebocontrolledrandomizedtrial
AT werreandriesj pulsedelectromagneticfieldsinthetreatmentoffreshscaphoidfracturesamulticenterprospectivedoubleblindplacebocontrolledrandomizedtrial
AT poezemartijn pulsedelectromagneticfieldsinthetreatmentoffreshscaphoidfracturesamulticenterprospectivedoubleblindplacebocontrolledrandomizedtrial
AT brinkpeterrg pulsedelectromagneticfieldsinthetreatmentoffreshscaphoidfracturesamulticenterprospectivedoubleblindplacebocontrolledrandomizedtrial