Cargando…
Pulsed Electromagnetic Fields in the treatment of fresh scaphoid fractures. A multicenter, prospective, double blind, placebo controlled, randomized trial
BACKGROUND: The scaphoid bone is the most commonly fractured of the carpal bones. In the Netherlands 90% of all carpal fractures is a fracture of the scaphoid bone. The scaphoid has an essential role in functionality of the wrist, acting as a pivot. Complications in healing can result in poor functi...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3107178/ https://www.ncbi.nlm.nih.gov/pubmed/21548951 http://dx.doi.org/10.1186/1471-2474-12-90 |
_version_ | 1782205200970285056 |
---|---|
author | Hannemann, Pascal Göttgens, Kevin WA van Wely, Bob J Kolkman, Karel A Werre, Andries J Poeze, Martijn Brink, Peter RG |
author_facet | Hannemann, Pascal Göttgens, Kevin WA van Wely, Bob J Kolkman, Karel A Werre, Andries J Poeze, Martijn Brink, Peter RG |
author_sort | Hannemann, Pascal |
collection | PubMed |
description | BACKGROUND: The scaphoid bone is the most commonly fractured of the carpal bones. In the Netherlands 90% of all carpal fractures is a fracture of the scaphoid bone. The scaphoid has an essential role in functionality of the wrist, acting as a pivot. Complications in healing can result in poor functional outcome. The scaphoid fracture is a troublesome fracture and failure of treatment can result in avascular necrosis (up to 40%), non-union (5-21%) and early osteo-arthritis (up to 32%) which may seriously impair wrist function. Impaired consolidation of scaphoid fractures results in longer immobilization and more days lost at work with significant psychosocial and financial consequences. Initially Pulsed Electromagnetic Fields was used in the treatment of tibial pseudoarthrosis and non-union. More recently there is evidence that physical forces can also be used in the treatment of fresh fractures, showing accelerated healing by 30% and 71% reduction in nonunion within 12 weeks after initiation of therapy. Until now no double blind randomized, placebo controlled trial has been conducted to investigate the effect of this treatment on the healing of fresh fractures of the scaphoid. METHODS/DESIGN: This is a multi center, prospective, double blind, placebo controlled, randomized trial. Study population consists of all patients with unilateral acute scaphoid fracture. Pregnant women, patients having a life supporting implanted electronic device, patients with additional fractures of wrist, carpal or metacarpal bones and pre-existing impairment in wrist function are excluded. The scaphoid fracture is diagnosed by a combination of physical and radiographic examination (CT-scanning). Proven scaphoid fractures are treated with cast immobilization and a small Pulsed Electromagnetic Fields bone growth stimulating device placed on the cast. Half of the devices will be disabled at random in the factory. Study parameters are clinical consolidation, radiological consolidation evaluated by CT-scanning, functional status of the wrist, including assessment by means of the patient rated wrist evaluation (PRWE) questionnaire and quality of life using SF-36 health survey questionnaire. Primary endpoint is number of scaphoid unions at six weeks, secondary endpoints are time interval to clinical and radiological consolidation, number of non-unions, functional status at 52 weeks and non-adherence to the treatment protocol. TRIAL REGISTRATION: Netherlands Trial Register (NTR): NTR2064 |
format | Online Article Text |
id | pubmed-3107178 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-31071782011-06-03 Pulsed Electromagnetic Fields in the treatment of fresh scaphoid fractures. A multicenter, prospective, double blind, placebo controlled, randomized trial Hannemann, Pascal Göttgens, Kevin WA van Wely, Bob J Kolkman, Karel A Werre, Andries J Poeze, Martijn Brink, Peter RG BMC Musculoskelet Disord Study Protocol BACKGROUND: The scaphoid bone is the most commonly fractured of the carpal bones. In the Netherlands 90% of all carpal fractures is a fracture of the scaphoid bone. The scaphoid has an essential role in functionality of the wrist, acting as a pivot. Complications in healing can result in poor functional outcome. The scaphoid fracture is a troublesome fracture and failure of treatment can result in avascular necrosis (up to 40%), non-union (5-21%) and early osteo-arthritis (up to 32%) which may seriously impair wrist function. Impaired consolidation of scaphoid fractures results in longer immobilization and more days lost at work with significant psychosocial and financial consequences. Initially Pulsed Electromagnetic Fields was used in the treatment of tibial pseudoarthrosis and non-union. More recently there is evidence that physical forces can also be used in the treatment of fresh fractures, showing accelerated healing by 30% and 71% reduction in nonunion within 12 weeks after initiation of therapy. Until now no double blind randomized, placebo controlled trial has been conducted to investigate the effect of this treatment on the healing of fresh fractures of the scaphoid. METHODS/DESIGN: This is a multi center, prospective, double blind, placebo controlled, randomized trial. Study population consists of all patients with unilateral acute scaphoid fracture. Pregnant women, patients having a life supporting implanted electronic device, patients with additional fractures of wrist, carpal or metacarpal bones and pre-existing impairment in wrist function are excluded. The scaphoid fracture is diagnosed by a combination of physical and radiographic examination (CT-scanning). Proven scaphoid fractures are treated with cast immobilization and a small Pulsed Electromagnetic Fields bone growth stimulating device placed on the cast. Half of the devices will be disabled at random in the factory. Study parameters are clinical consolidation, radiological consolidation evaluated by CT-scanning, functional status of the wrist, including assessment by means of the patient rated wrist evaluation (PRWE) questionnaire and quality of life using SF-36 health survey questionnaire. Primary endpoint is number of scaphoid unions at six weeks, secondary endpoints are time interval to clinical and radiological consolidation, number of non-unions, functional status at 52 weeks and non-adherence to the treatment protocol. TRIAL REGISTRATION: Netherlands Trial Register (NTR): NTR2064 BioMed Central 2011-05-06 /pmc/articles/PMC3107178/ /pubmed/21548951 http://dx.doi.org/10.1186/1471-2474-12-90 Text en Copyright ©2011 Hannemann et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Study Protocol Hannemann, Pascal Göttgens, Kevin WA van Wely, Bob J Kolkman, Karel A Werre, Andries J Poeze, Martijn Brink, Peter RG Pulsed Electromagnetic Fields in the treatment of fresh scaphoid fractures. A multicenter, prospective, double blind, placebo controlled, randomized trial |
title | Pulsed Electromagnetic Fields in the treatment of fresh scaphoid fractures. A multicenter, prospective, double blind, placebo controlled, randomized trial |
title_full | Pulsed Electromagnetic Fields in the treatment of fresh scaphoid fractures. A multicenter, prospective, double blind, placebo controlled, randomized trial |
title_fullStr | Pulsed Electromagnetic Fields in the treatment of fresh scaphoid fractures. A multicenter, prospective, double blind, placebo controlled, randomized trial |
title_full_unstemmed | Pulsed Electromagnetic Fields in the treatment of fresh scaphoid fractures. A multicenter, prospective, double blind, placebo controlled, randomized trial |
title_short | Pulsed Electromagnetic Fields in the treatment of fresh scaphoid fractures. A multicenter, prospective, double blind, placebo controlled, randomized trial |
title_sort | pulsed electromagnetic fields in the treatment of fresh scaphoid fractures. a multicenter, prospective, double blind, placebo controlled, randomized trial |
topic | Study Protocol |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3107178/ https://www.ncbi.nlm.nih.gov/pubmed/21548951 http://dx.doi.org/10.1186/1471-2474-12-90 |
work_keys_str_mv | AT hannemannpascal pulsedelectromagneticfieldsinthetreatmentoffreshscaphoidfracturesamulticenterprospectivedoubleblindplacebocontrolledrandomizedtrial AT gottgenskevinwa pulsedelectromagneticfieldsinthetreatmentoffreshscaphoidfracturesamulticenterprospectivedoubleblindplacebocontrolledrandomizedtrial AT vanwelybobj pulsedelectromagneticfieldsinthetreatmentoffreshscaphoidfracturesamulticenterprospectivedoubleblindplacebocontrolledrandomizedtrial AT kolkmankarela pulsedelectromagneticfieldsinthetreatmentoffreshscaphoidfracturesamulticenterprospectivedoubleblindplacebocontrolledrandomizedtrial AT werreandriesj pulsedelectromagneticfieldsinthetreatmentoffreshscaphoidfracturesamulticenterprospectivedoubleblindplacebocontrolledrandomizedtrial AT poezemartijn pulsedelectromagneticfieldsinthetreatmentoffreshscaphoidfracturesamulticenterprospectivedoubleblindplacebocontrolledrandomizedtrial AT brinkpeterrg pulsedelectromagneticfieldsinthetreatmentoffreshscaphoidfracturesamulticenterprospectivedoubleblindplacebocontrolledrandomizedtrial |