Cargando…
The impact of physiological noise correction on fMRI at 7 T
Cognitive neuroimaging studies typically require fast whole brain image acquisition with maximal sensitivity to small BOLD signal changes. To increase the sensitivity, higher field strengths are often employed, since they provide an increased image signal-to-noise ratio (SNR). However, as image SNR...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Academic Press
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3115139/ https://www.ncbi.nlm.nih.gov/pubmed/21515386 http://dx.doi.org/10.1016/j.neuroimage.2011.04.018 |
_version_ | 1782206139587362816 |
---|---|
author | Hutton, C. Josephs, O. Stadler, J. Featherstone, E. Reid, A. Speck, O. Bernarding, J. Weiskopf, N. |
author_facet | Hutton, C. Josephs, O. Stadler, J. Featherstone, E. Reid, A. Speck, O. Bernarding, J. Weiskopf, N. |
author_sort | Hutton, C. |
collection | PubMed |
description | Cognitive neuroimaging studies typically require fast whole brain image acquisition with maximal sensitivity to small BOLD signal changes. To increase the sensitivity, higher field strengths are often employed, since they provide an increased image signal-to-noise ratio (SNR). However, as image SNR increases, the relative contribution of physiological noise to the total time series noise will be greater compared to that from thermal noise. At 7 T, we studied how the physiological noise contribution can be best reduced for EPI time series acquired at three different spatial resolutions (1.1 mm × 1.1 mm × 1.8 mm, 2 mm × 2 mm × 2 mm and 3 mm × 3 mm × 3 mm). Applying optimal physiological noise correction methods improved temporal SNR (tSNR) and increased the numbers of significantly activated voxels in fMRI visual activation studies for all sets of acquisition parameters. The most dramatic results were achieved for the lowest spatial resolution, an acquisition parameter combination commonly used in cognitive neuroimaging which requires high functional sensitivity and temporal resolution (i.e. 3 mm isotropic resolution and whole brain image repetition time of 2 s). For this data, physiological noise models based on cardio-respiratory information improved tSNR by approximately 25% in the visual cortex and 35% sub-cortically. When the time series were additionally corrected for the residual effects of head motion after retrospective realignment, the tSNR was increased by around 58% in the visual cortex and 71% sub-cortically, exceeding tSNR ~ 140. In conclusion, optimal physiological noise correction at 7 T increases tSNR significantly, resulting in the highest tSNR per unit time published so far. This tSNR improvement translates into a significant increase in BOLD sensitivity, facilitating the study of even subtle BOLD responses. |
format | Online Article Text |
id | pubmed-3115139 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Academic Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-31151392011-07-20 The impact of physiological noise correction on fMRI at 7 T Hutton, C. Josephs, O. Stadler, J. Featherstone, E. Reid, A. Speck, O. Bernarding, J. Weiskopf, N. Neuroimage Article Cognitive neuroimaging studies typically require fast whole brain image acquisition with maximal sensitivity to small BOLD signal changes. To increase the sensitivity, higher field strengths are often employed, since they provide an increased image signal-to-noise ratio (SNR). However, as image SNR increases, the relative contribution of physiological noise to the total time series noise will be greater compared to that from thermal noise. At 7 T, we studied how the physiological noise contribution can be best reduced for EPI time series acquired at three different spatial resolutions (1.1 mm × 1.1 mm × 1.8 mm, 2 mm × 2 mm × 2 mm and 3 mm × 3 mm × 3 mm). Applying optimal physiological noise correction methods improved temporal SNR (tSNR) and increased the numbers of significantly activated voxels in fMRI visual activation studies for all sets of acquisition parameters. The most dramatic results were achieved for the lowest spatial resolution, an acquisition parameter combination commonly used in cognitive neuroimaging which requires high functional sensitivity and temporal resolution (i.e. 3 mm isotropic resolution and whole brain image repetition time of 2 s). For this data, physiological noise models based on cardio-respiratory information improved tSNR by approximately 25% in the visual cortex and 35% sub-cortically. When the time series were additionally corrected for the residual effects of head motion after retrospective realignment, the tSNR was increased by around 58% in the visual cortex and 71% sub-cortically, exceeding tSNR ~ 140. In conclusion, optimal physiological noise correction at 7 T increases tSNR significantly, resulting in the highest tSNR per unit time published so far. This tSNR improvement translates into a significant increase in BOLD sensitivity, facilitating the study of even subtle BOLD responses. Academic Press 2011-07-01 /pmc/articles/PMC3115139/ /pubmed/21515386 http://dx.doi.org/10.1016/j.neuroimage.2011.04.018 Text en © 2011 Elsevier Inc. https://creativecommons.org/licenses/by/3.0/ Open Access under CC BY 3.0 (https://creativecommons.org/licenses/by/3.0/) license |
spellingShingle | Article Hutton, C. Josephs, O. Stadler, J. Featherstone, E. Reid, A. Speck, O. Bernarding, J. Weiskopf, N. The impact of physiological noise correction on fMRI at 7 T |
title | The impact of physiological noise correction on fMRI at 7 T |
title_full | The impact of physiological noise correction on fMRI at 7 T |
title_fullStr | The impact of physiological noise correction on fMRI at 7 T |
title_full_unstemmed | The impact of physiological noise correction on fMRI at 7 T |
title_short | The impact of physiological noise correction on fMRI at 7 T |
title_sort | impact of physiological noise correction on fmri at 7 t |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3115139/ https://www.ncbi.nlm.nih.gov/pubmed/21515386 http://dx.doi.org/10.1016/j.neuroimage.2011.04.018 |
work_keys_str_mv | AT huttonc theimpactofphysiologicalnoisecorrectiononfmriat7t AT josephso theimpactofphysiologicalnoisecorrectiononfmriat7t AT stadlerj theimpactofphysiologicalnoisecorrectiononfmriat7t AT featherstonee theimpactofphysiologicalnoisecorrectiononfmriat7t AT reida theimpactofphysiologicalnoisecorrectiononfmriat7t AT specko theimpactofphysiologicalnoisecorrectiononfmriat7t AT bernardingj theimpactofphysiologicalnoisecorrectiononfmriat7t AT weiskopfn theimpactofphysiologicalnoisecorrectiononfmriat7t AT huttonc impactofphysiologicalnoisecorrectiononfmriat7t AT josephso impactofphysiologicalnoisecorrectiononfmriat7t AT stadlerj impactofphysiologicalnoisecorrectiononfmriat7t AT featherstonee impactofphysiologicalnoisecorrectiononfmriat7t AT reida impactofphysiologicalnoisecorrectiononfmriat7t AT specko impactofphysiologicalnoisecorrectiononfmriat7t AT bernardingj impactofphysiologicalnoisecorrectiononfmriat7t AT weiskopfn impactofphysiologicalnoisecorrectiononfmriat7t |