Cargando…

The impact of physiological noise correction on fMRI at 7 T

Cognitive neuroimaging studies typically require fast whole brain image acquisition with maximal sensitivity to small BOLD signal changes. To increase the sensitivity, higher field strengths are often employed, since they provide an increased image signal-to-noise ratio (SNR). However, as image SNR...

Descripción completa

Detalles Bibliográficos
Autores principales: Hutton, C., Josephs, O., Stadler, J., Featherstone, E., Reid, A., Speck, O., Bernarding, J., Weiskopf, N.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Academic Press 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3115139/
https://www.ncbi.nlm.nih.gov/pubmed/21515386
http://dx.doi.org/10.1016/j.neuroimage.2011.04.018
_version_ 1782206139587362816
author Hutton, C.
Josephs, O.
Stadler, J.
Featherstone, E.
Reid, A.
Speck, O.
Bernarding, J.
Weiskopf, N.
author_facet Hutton, C.
Josephs, O.
Stadler, J.
Featherstone, E.
Reid, A.
Speck, O.
Bernarding, J.
Weiskopf, N.
author_sort Hutton, C.
collection PubMed
description Cognitive neuroimaging studies typically require fast whole brain image acquisition with maximal sensitivity to small BOLD signal changes. To increase the sensitivity, higher field strengths are often employed, since they provide an increased image signal-to-noise ratio (SNR). However, as image SNR increases, the relative contribution of physiological noise to the total time series noise will be greater compared to that from thermal noise. At 7 T, we studied how the physiological noise contribution can be best reduced for EPI time series acquired at three different spatial resolutions (1.1 mm × 1.1 mm × 1.8 mm, 2 mm × 2 mm × 2 mm and 3 mm × 3 mm × 3 mm). Applying optimal physiological noise correction methods improved temporal SNR (tSNR) and increased the numbers of significantly activated voxels in fMRI visual activation studies for all sets of acquisition parameters. The most dramatic results were achieved for the lowest spatial resolution, an acquisition parameter combination commonly used in cognitive neuroimaging which requires high functional sensitivity and temporal resolution (i.e. 3 mm isotropic resolution and whole brain image repetition time of 2 s). For this data, physiological noise models based on cardio-respiratory information improved tSNR by approximately 25% in the visual cortex and 35% sub-cortically. When the time series were additionally corrected for the residual effects of head motion after retrospective realignment, the tSNR was increased by around 58% in the visual cortex and 71% sub-cortically, exceeding tSNR ~ 140. In conclusion, optimal physiological noise correction at 7 T increases tSNR significantly, resulting in the highest tSNR per unit time published so far. This tSNR improvement translates into a significant increase in BOLD sensitivity, facilitating the study of even subtle BOLD responses.
format Online
Article
Text
id pubmed-3115139
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Academic Press
record_format MEDLINE/PubMed
spelling pubmed-31151392011-07-20 The impact of physiological noise correction on fMRI at 7 T Hutton, C. Josephs, O. Stadler, J. Featherstone, E. Reid, A. Speck, O. Bernarding, J. Weiskopf, N. Neuroimage Article Cognitive neuroimaging studies typically require fast whole brain image acquisition with maximal sensitivity to small BOLD signal changes. To increase the sensitivity, higher field strengths are often employed, since they provide an increased image signal-to-noise ratio (SNR). However, as image SNR increases, the relative contribution of physiological noise to the total time series noise will be greater compared to that from thermal noise. At 7 T, we studied how the physiological noise contribution can be best reduced for EPI time series acquired at three different spatial resolutions (1.1 mm × 1.1 mm × 1.8 mm, 2 mm × 2 mm × 2 mm and 3 mm × 3 mm × 3 mm). Applying optimal physiological noise correction methods improved temporal SNR (tSNR) and increased the numbers of significantly activated voxels in fMRI visual activation studies for all sets of acquisition parameters. The most dramatic results were achieved for the lowest spatial resolution, an acquisition parameter combination commonly used in cognitive neuroimaging which requires high functional sensitivity and temporal resolution (i.e. 3 mm isotropic resolution and whole brain image repetition time of 2 s). For this data, physiological noise models based on cardio-respiratory information improved tSNR by approximately 25% in the visual cortex and 35% sub-cortically. When the time series were additionally corrected for the residual effects of head motion after retrospective realignment, the tSNR was increased by around 58% in the visual cortex and 71% sub-cortically, exceeding tSNR ~ 140. In conclusion, optimal physiological noise correction at 7 T increases tSNR significantly, resulting in the highest tSNR per unit time published so far. This tSNR improvement translates into a significant increase in BOLD sensitivity, facilitating the study of even subtle BOLD responses. Academic Press 2011-07-01 /pmc/articles/PMC3115139/ /pubmed/21515386 http://dx.doi.org/10.1016/j.neuroimage.2011.04.018 Text en © 2011 Elsevier Inc. https://creativecommons.org/licenses/by/3.0/ Open Access under CC BY 3.0 (https://creativecommons.org/licenses/by/3.0/) license
spellingShingle Article
Hutton, C.
Josephs, O.
Stadler, J.
Featherstone, E.
Reid, A.
Speck, O.
Bernarding, J.
Weiskopf, N.
The impact of physiological noise correction on fMRI at 7 T
title The impact of physiological noise correction on fMRI at 7 T
title_full The impact of physiological noise correction on fMRI at 7 T
title_fullStr The impact of physiological noise correction on fMRI at 7 T
title_full_unstemmed The impact of physiological noise correction on fMRI at 7 T
title_short The impact of physiological noise correction on fMRI at 7 T
title_sort impact of physiological noise correction on fmri at 7 t
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3115139/
https://www.ncbi.nlm.nih.gov/pubmed/21515386
http://dx.doi.org/10.1016/j.neuroimage.2011.04.018
work_keys_str_mv AT huttonc theimpactofphysiologicalnoisecorrectiononfmriat7t
AT josephso theimpactofphysiologicalnoisecorrectiononfmriat7t
AT stadlerj theimpactofphysiologicalnoisecorrectiononfmriat7t
AT featherstonee theimpactofphysiologicalnoisecorrectiononfmriat7t
AT reida theimpactofphysiologicalnoisecorrectiononfmriat7t
AT specko theimpactofphysiologicalnoisecorrectiononfmriat7t
AT bernardingj theimpactofphysiologicalnoisecorrectiononfmriat7t
AT weiskopfn theimpactofphysiologicalnoisecorrectiononfmriat7t
AT huttonc impactofphysiologicalnoisecorrectiononfmriat7t
AT josephso impactofphysiologicalnoisecorrectiononfmriat7t
AT stadlerj impactofphysiologicalnoisecorrectiononfmriat7t
AT featherstonee impactofphysiologicalnoisecorrectiononfmriat7t
AT reida impactofphysiologicalnoisecorrectiononfmriat7t
AT specko impactofphysiologicalnoisecorrectiononfmriat7t
AT bernardingj impactofphysiologicalnoisecorrectiononfmriat7t
AT weiskopfn impactofphysiologicalnoisecorrectiononfmriat7t