Cargando…

Delayed endovascular treatment of descending aorta stent graft collapse in a patient treated for post- traumatic aortic rupture: a case report

BACKGROUND: We report a case of delayed endovascular correction of graft collapse occurred after emergent Thoracic Endovascular Aortic Repair (TEVAR) for traumatic aortic isthmus rupture. CASE PRESENTATION: In 7(th )post-operative day after emergent TEVAR for traumatic aortic isthmus rupture (Gore T...

Descripción completa

Detalles Bibliográficos
Autores principales: Nano, Giovanni, Mazzaccaro, Daniela, Malacrida, Giovanni, Occhiuto, Maria Teresa, Stegher, Silvia, Tealdi, Domenico G
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2011