Cargando…
Prediction of the annuloplasty ring size in patients undergoing mitral valve repair using real-time three-dimensional transoesophageal echocardiography
AIMS: We sought to investigate the additional value of real-time three-dimensional transoesophageal echocardiography (RT 3D TOE)-guided sizing for predicting annuloplasty ring size during mitral valve repair. METHODS AND RESULTS: In 53 patients undergoing elective mitral valve repair, an RT 3D TOE w...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3117468/ https://www.ncbi.nlm.nih.gov/pubmed/21546375 http://dx.doi.org/10.1093/ejechocard/jer042 |
_version_ | 1782206338191851520 |
---|---|
author | Ender, J. Eibel, S. Mukherjee, C. Mathioudakis, D. Borger, M.A. Jacobs, S. Mohr, F.W. Falk, V. |
author_facet | Ender, J. Eibel, S. Mukherjee, C. Mathioudakis, D. Borger, M.A. Jacobs, S. Mohr, F.W. Falk, V. |
author_sort | Ender, J. |
collection | PubMed |
description | AIMS: We sought to investigate the additional value of real-time three-dimensional transoesophageal echocardiography (RT 3D TOE)-guided sizing for predicting annuloplasty ring size during mitral valve repair. METHODS AND RESULTS: In 53 patients undergoing elective mitral valve repair, an RT 3D TOE was performed pre- and post-operatively. The digitally stored loops were imported into a software for mitral valve assessment. The annuloplasty ring size was predicted by superimposing computer-aided design (CAD) models of annuloplasty rings onto Live 3D zoom loops, measurement of the intercommissural distance, or the height of the anterior mitral leaflet. The surgeon implanted the annuloplasty ring according to the usual surgical technique and was blinded to the echocardiographic measurement results. Pre-operative correlation between the selected ring size with mitral valve assessment and the actual implanted annuloplasty ring size was 0.91. The correlation for measurement of the intercommissural distance was 0.55 and for measurement of the height of the anterior mitral leaflet 0.75. The post-operative correlation with the actual implanted ring size was 0.96 for mitral valve assessment, 0.92 for intercommissural distance, and 0.79 for the anterior mitral leaflet height. CONCLUSION: Superimposition of annuloplasty ring CAD models on the Live 3D zoom loops of the mitral valve using mitral valve assessment is superior to two-dimensional measurements of the intercommissural distance or the height of the anterior mitral leaflet in predicting correct annuloplasty ring size. |
format | Online Article Text |
id | pubmed-3117468 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-31174682011-06-20 Prediction of the annuloplasty ring size in patients undergoing mitral valve repair using real-time three-dimensional transoesophageal echocardiography Ender, J. Eibel, S. Mukherjee, C. Mathioudakis, D. Borger, M.A. Jacobs, S. Mohr, F.W. Falk, V. Eur J Echocardiogr Clinical/Original Papers AIMS: We sought to investigate the additional value of real-time three-dimensional transoesophageal echocardiography (RT 3D TOE)-guided sizing for predicting annuloplasty ring size during mitral valve repair. METHODS AND RESULTS: In 53 patients undergoing elective mitral valve repair, an RT 3D TOE was performed pre- and post-operatively. The digitally stored loops were imported into a software for mitral valve assessment. The annuloplasty ring size was predicted by superimposing computer-aided design (CAD) models of annuloplasty rings onto Live 3D zoom loops, measurement of the intercommissural distance, or the height of the anterior mitral leaflet. The surgeon implanted the annuloplasty ring according to the usual surgical technique and was blinded to the echocardiographic measurement results. Pre-operative correlation between the selected ring size with mitral valve assessment and the actual implanted annuloplasty ring size was 0.91. The correlation for measurement of the intercommissural distance was 0.55 and for measurement of the height of the anterior mitral leaflet 0.75. The post-operative correlation with the actual implanted ring size was 0.96 for mitral valve assessment, 0.92 for intercommissural distance, and 0.79 for the anterior mitral leaflet height. CONCLUSION: Superimposition of annuloplasty ring CAD models on the Live 3D zoom loops of the mitral valve using mitral valve assessment is superior to two-dimensional measurements of the intercommissural distance or the height of the anterior mitral leaflet in predicting correct annuloplasty ring size. Oxford University Press 2011-06 2011-05-04 /pmc/articles/PMC3117468/ /pubmed/21546375 http://dx.doi.org/10.1093/ejechocard/jer042 Text en Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2011. For permissions please email: journals.permissions@oup.com http://creativecommons.org/licenses/by-nc/2.5/uk/ The online version of this article has been published under an open access model. Users are entitled to use, reproduce, disseminate, or display the open access version of this article for non-commercial purposes provided that the original authorship is properly and fully attributed; the Journal, Learned Society and Oxford University Press are attributed as the original place of publication with correct citation details given; if an article is subsequently reproduced or disseminated not in its entirety but only in part or as a derivative work this must be clearly indicated. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Clinical/Original Papers Ender, J. Eibel, S. Mukherjee, C. Mathioudakis, D. Borger, M.A. Jacobs, S. Mohr, F.W. Falk, V. Prediction of the annuloplasty ring size in patients undergoing mitral valve repair using real-time three-dimensional transoesophageal echocardiography |
title | Prediction of the annuloplasty ring size in patients undergoing mitral valve repair using real-time three-dimensional transoesophageal echocardiography |
title_full | Prediction of the annuloplasty ring size in patients undergoing mitral valve repair using real-time three-dimensional transoesophageal echocardiography |
title_fullStr | Prediction of the annuloplasty ring size in patients undergoing mitral valve repair using real-time three-dimensional transoesophageal echocardiography |
title_full_unstemmed | Prediction of the annuloplasty ring size in patients undergoing mitral valve repair using real-time three-dimensional transoesophageal echocardiography |
title_short | Prediction of the annuloplasty ring size in patients undergoing mitral valve repair using real-time three-dimensional transoesophageal echocardiography |
title_sort | prediction of the annuloplasty ring size in patients undergoing mitral valve repair using real-time three-dimensional transoesophageal echocardiography |
topic | Clinical/Original Papers |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3117468/ https://www.ncbi.nlm.nih.gov/pubmed/21546375 http://dx.doi.org/10.1093/ejechocard/jer042 |
work_keys_str_mv | AT enderj predictionoftheannuloplastyringsizeinpatientsundergoingmitralvalverepairusingrealtimethreedimensionaltransoesophagealechocardiography AT eibels predictionoftheannuloplastyringsizeinpatientsundergoingmitralvalverepairusingrealtimethreedimensionaltransoesophagealechocardiography AT mukherjeec predictionoftheannuloplastyringsizeinpatientsundergoingmitralvalverepairusingrealtimethreedimensionaltransoesophagealechocardiography AT mathioudakisd predictionoftheannuloplastyringsizeinpatientsundergoingmitralvalverepairusingrealtimethreedimensionaltransoesophagealechocardiography AT borgerma predictionoftheannuloplastyringsizeinpatientsundergoingmitralvalverepairusingrealtimethreedimensionaltransoesophagealechocardiography AT jacobss predictionoftheannuloplastyringsizeinpatientsundergoingmitralvalverepairusingrealtimethreedimensionaltransoesophagealechocardiography AT mohrfw predictionoftheannuloplastyringsizeinpatientsundergoingmitralvalverepairusingrealtimethreedimensionaltransoesophagealechocardiography AT falkv predictionoftheannuloplastyringsizeinpatientsundergoingmitralvalverepairusingrealtimethreedimensionaltransoesophagealechocardiography |