Cargando…

Reconstruction of the esophagojejunostomy by double stapling method using EEA™ OrVil™ in laparoscopic total gastrectomy and proximal gastrectomy

Here we report the method of anastomosis based on double stapling technique (hereinafter, DST) using a trans-oral anvil delivery system (EEATM OrVilTM) for reconstructing the esophagus and lifted jejunum following laparoscopic total gastrectomy or proximal gastric resection. As a basic technique, la...

Descripción completa

Detalles Bibliográficos
Autores principales: Hirahara, Noriyuki, Monma, Hiroyuki, Shimojo, Yoshihide, Matsubara, Takeshi, Hyakudomi, Ryoji, Yano, Seiji, Tanaka, Tsuneo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3118377/
https://www.ncbi.nlm.nih.gov/pubmed/21599911
http://dx.doi.org/10.1186/1477-7819-9-55
_version_ 1782206468718592000
author Hirahara, Noriyuki
Monma, Hiroyuki
Shimojo, Yoshihide
Matsubara, Takeshi
Hyakudomi, Ryoji
Yano, Seiji
Tanaka, Tsuneo
author_facet Hirahara, Noriyuki
Monma, Hiroyuki
Shimojo, Yoshihide
Matsubara, Takeshi
Hyakudomi, Ryoji
Yano, Seiji
Tanaka, Tsuneo
author_sort Hirahara, Noriyuki
collection PubMed
description Here we report the method of anastomosis based on double stapling technique (hereinafter, DST) using a trans-oral anvil delivery system (EEATM OrVilTM) for reconstructing the esophagus and lifted jejunum following laparoscopic total gastrectomy or proximal gastric resection. As a basic technique, laparoscopic total gastrectomy employed Roux-en-Y reconstruction, laparoscopic proximal gastrectomy employed double tract reconstruction, and end-to-side anastomosis was used for the cut-off stump of the esophagus and lifted jejunum. We used EEATM OrVilTM as a device that permitted mechanical purse-string suture similarly to conventional EEA, and endo-Surgitie. After the gastric lymph node dissection, the esophagus was cut off using an automated stapler. EEATM OrVilTM was orally and slowly inserted from the valve tip, and a small hole was created at the tip of the obliquely cut-off stump with scissors to let the valve tip pass through. Yarn was cut to disconnect the anvil from a tube and the anvil head was retained in the esophagus. The end-Surgitie was inserted at the right subcostal margin, and after the looped-shaped thread was wrapped around the esophageal stump opening, assisting Maryland forceps inserted at the left subcostal and left abdomen were used to grasp the left and right esophageal stump. The surgeon inserted anvil grasping forceps into the right abdomen, and after grasping the esophagus with the forceps, tightened the end Surgitie, thereby completing the purse-string suture on the esophageal stump. The main unit of the automated stapler was inserted from the cut-off stump of the lifted jejunum, and a trocar was made to pass through. To prevent dropout of the small intestines from the automated stapler, the automated stapler and the lifted jejunum were fastened with silk thread, the abdomen was again inflated, and the lifted jejunum was led into the abdominal cavity. When it was confirmed that the automated stapler and center rod were made completely linear, the anvil and the main unit were connected with each other and firing was carried out. Then, DST-based anastomosis was completed with no dog-ear. The method may facilitate safe laparoscopic anastomosis between the esophagus and reconstructed intestine. This is also considered to serve as a useful anastomosis technique for upper levels of the esophagus in laparotomy.
format Online
Article
Text
id pubmed-3118377
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-31183772011-06-20 Reconstruction of the esophagojejunostomy by double stapling method using EEA™ OrVil™ in laparoscopic total gastrectomy and proximal gastrectomy Hirahara, Noriyuki Monma, Hiroyuki Shimojo, Yoshihide Matsubara, Takeshi Hyakudomi, Ryoji Yano, Seiji Tanaka, Tsuneo World J Surg Oncol Technical Innovations Here we report the method of anastomosis based on double stapling technique (hereinafter, DST) using a trans-oral anvil delivery system (EEATM OrVilTM) for reconstructing the esophagus and lifted jejunum following laparoscopic total gastrectomy or proximal gastric resection. As a basic technique, laparoscopic total gastrectomy employed Roux-en-Y reconstruction, laparoscopic proximal gastrectomy employed double tract reconstruction, and end-to-side anastomosis was used for the cut-off stump of the esophagus and lifted jejunum. We used EEATM OrVilTM as a device that permitted mechanical purse-string suture similarly to conventional EEA, and endo-Surgitie. After the gastric lymph node dissection, the esophagus was cut off using an automated stapler. EEATM OrVilTM was orally and slowly inserted from the valve tip, and a small hole was created at the tip of the obliquely cut-off stump with scissors to let the valve tip pass through. Yarn was cut to disconnect the anvil from a tube and the anvil head was retained in the esophagus. The end-Surgitie was inserted at the right subcostal margin, and after the looped-shaped thread was wrapped around the esophageal stump opening, assisting Maryland forceps inserted at the left subcostal and left abdomen were used to grasp the left and right esophageal stump. The surgeon inserted anvil grasping forceps into the right abdomen, and after grasping the esophagus with the forceps, tightened the end Surgitie, thereby completing the purse-string suture on the esophageal stump. The main unit of the automated stapler was inserted from the cut-off stump of the lifted jejunum, and a trocar was made to pass through. To prevent dropout of the small intestines from the automated stapler, the automated stapler and the lifted jejunum were fastened with silk thread, the abdomen was again inflated, and the lifted jejunum was led into the abdominal cavity. When it was confirmed that the automated stapler and center rod were made completely linear, the anvil and the main unit were connected with each other and firing was carried out. Then, DST-based anastomosis was completed with no dog-ear. The method may facilitate safe laparoscopic anastomosis between the esophagus and reconstructed intestine. This is also considered to serve as a useful anastomosis technique for upper levels of the esophagus in laparotomy. BioMed Central 2011-05-20 /pmc/articles/PMC3118377/ /pubmed/21599911 http://dx.doi.org/10.1186/1477-7819-9-55 Text en Copyright ©2011 Hirahara et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technical Innovations
Hirahara, Noriyuki
Monma, Hiroyuki
Shimojo, Yoshihide
Matsubara, Takeshi
Hyakudomi, Ryoji
Yano, Seiji
Tanaka, Tsuneo
Reconstruction of the esophagojejunostomy by double stapling method using EEA™ OrVil™ in laparoscopic total gastrectomy and proximal gastrectomy
title Reconstruction of the esophagojejunostomy by double stapling method using EEA™ OrVil™ in laparoscopic total gastrectomy and proximal gastrectomy
title_full Reconstruction of the esophagojejunostomy by double stapling method using EEA™ OrVil™ in laparoscopic total gastrectomy and proximal gastrectomy
title_fullStr Reconstruction of the esophagojejunostomy by double stapling method using EEA™ OrVil™ in laparoscopic total gastrectomy and proximal gastrectomy
title_full_unstemmed Reconstruction of the esophagojejunostomy by double stapling method using EEA™ OrVil™ in laparoscopic total gastrectomy and proximal gastrectomy
title_short Reconstruction of the esophagojejunostomy by double stapling method using EEA™ OrVil™ in laparoscopic total gastrectomy and proximal gastrectomy
title_sort reconstruction of the esophagojejunostomy by double stapling method using eea™ orvil™ in laparoscopic total gastrectomy and proximal gastrectomy
topic Technical Innovations
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3118377/
https://www.ncbi.nlm.nih.gov/pubmed/21599911
http://dx.doi.org/10.1186/1477-7819-9-55
work_keys_str_mv AT hiraharanoriyuki reconstructionoftheesophagojejunostomybydoublestaplingmethodusingeeaorvilinlaparoscopictotalgastrectomyandproximalgastrectomy
AT monmahiroyuki reconstructionoftheesophagojejunostomybydoublestaplingmethodusingeeaorvilinlaparoscopictotalgastrectomyandproximalgastrectomy
AT shimojoyoshihide reconstructionoftheesophagojejunostomybydoublestaplingmethodusingeeaorvilinlaparoscopictotalgastrectomyandproximalgastrectomy
AT matsubaratakeshi reconstructionoftheesophagojejunostomybydoublestaplingmethodusingeeaorvilinlaparoscopictotalgastrectomyandproximalgastrectomy
AT hyakudomiryoji reconstructionoftheesophagojejunostomybydoublestaplingmethodusingeeaorvilinlaparoscopictotalgastrectomyandproximalgastrectomy
AT yanoseiji reconstructionoftheesophagojejunostomybydoublestaplingmethodusingeeaorvilinlaparoscopictotalgastrectomyandproximalgastrectomy
AT tanakatsuneo reconstructionoftheesophagojejunostomybydoublestaplingmethodusingeeaorvilinlaparoscopictotalgastrectomyandproximalgastrectomy