Cargando…

Biological in-vivo measurement of dose distribution in patients' lymphocytes by gamma-H2AX immunofluorescence staining: 3D conformal- vs. step-and-shoot IMRT of the prostate gland

BACKGROUND: Different radiation-techniques in treating local staged prostate cancer differ in their dose- distribution. Physical phantom measurements indicate that for 3D, less healthy tissue is exposed to a relatively higher dose compared to SSIMRT. The purpose is to substantiate a dose distributio...

Descripción completa

Detalles Bibliográficos
Autores principales: Zwicker, Felix, Swartman, Benedict, Sterzing, Florian, Major, Gerald, Weber, Klaus-Josef, Huber, Peter E, Thieke, Christian, Debus, Jürgen, Herfarth, Klaus
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3121605/
https://www.ncbi.nlm.nih.gov/pubmed/21649920
http://dx.doi.org/10.1186/1748-717X-6-62
_version_ 1782206832766353408
author Zwicker, Felix
Swartman, Benedict
Sterzing, Florian
Major, Gerald
Weber, Klaus-Josef
Huber, Peter E
Thieke, Christian
Debus, Jürgen
Herfarth, Klaus
author_facet Zwicker, Felix
Swartman, Benedict
Sterzing, Florian
Major, Gerald
Weber, Klaus-Josef
Huber, Peter E
Thieke, Christian
Debus, Jürgen
Herfarth, Klaus
author_sort Zwicker, Felix
collection PubMed
description BACKGROUND: Different radiation-techniques in treating local staged prostate cancer differ in their dose- distribution. Physical phantom measurements indicate that for 3D, less healthy tissue is exposed to a relatively higher dose compared to SSIMRT. The purpose is to substantiate a dose distribution in lymphocytes in-vivo and to discuss the possibility of comparing it to the physical model of total body dose distribution. METHODS: For each technique (3D and SSIMRT), blood was taken from 20 patients before and 10 min after their first fraction of radiotherapy. The isolated leukocytes were fixed 2 hours after radiation. DNA double-strand breaks (DSB) in lymphocytes' nuclei were stained immunocytochemically using the gamma-H2AX protein. Gamma-H2AX foci inside each nucleus were counted in 300 irradiated as well as 50 non-irradiated lymphocytes per patient. In addition, lymphocytes of 5 volunteer subjects were irradiated externally at different doses and processed under same conditions as the patients' lymphocytes in order to generate a calibration-line. This calibration-line assigns dose-value to mean number of gamma-H2AX foci/ nucleus. So the dose distributions in patients' lymphocytes were determined regarding to the gamma-H2AX foci distribution. With this information a cumulative dose-lymphocyte-histogram (DLH) was generated. Visualized distribution of gamma-H2AX foci, correspondingly dose per nucleus, was compared to the technical dose-volume-histogram (DVH), related to the whole body-volume. RESULTS: Measured in-vivo (DLH) and according to the physical treatment-planning (DVH), more lymphocytes resulted with low-dose exposure (< 20% of the applied dose) and significantly fewer lymphocytes with middle-dose exposure (30%-60%) during Step-and-Shoot-IMRT, compared to conventional 3D conformal radiotherapy. The high-dose exposure (> 80%) was equal in both radiation techniques. The mean number of gamma-H2AX foci per lymphocyte was 0.49 (3D) and 0.47 (SSIMRT) without significant difference. CONCLUSIONS: In-vivo measurement of the dose distribution within patients' lymphocytes can be performed by detecting gamma-H2AX foci. In case of 3D and SSIMRT, the results of this method correlate with the physical calculated total body dose-distribution, but cannot be interpreted unrestrictedly due to the blood circulation. One possible application of the present method could be in radiation-protection for in-vivo dose estimation after accidental exposure to radiation.
format Online
Article
Text
id pubmed-3121605
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-31216052011-06-24 Biological in-vivo measurement of dose distribution in patients' lymphocytes by gamma-H2AX immunofluorescence staining: 3D conformal- vs. step-and-shoot IMRT of the prostate gland Zwicker, Felix Swartman, Benedict Sterzing, Florian Major, Gerald Weber, Klaus-Josef Huber, Peter E Thieke, Christian Debus, Jürgen Herfarth, Klaus Radiat Oncol Research BACKGROUND: Different radiation-techniques in treating local staged prostate cancer differ in their dose- distribution. Physical phantom measurements indicate that for 3D, less healthy tissue is exposed to a relatively higher dose compared to SSIMRT. The purpose is to substantiate a dose distribution in lymphocytes in-vivo and to discuss the possibility of comparing it to the physical model of total body dose distribution. METHODS: For each technique (3D and SSIMRT), blood was taken from 20 patients before and 10 min after their first fraction of radiotherapy. The isolated leukocytes were fixed 2 hours after radiation. DNA double-strand breaks (DSB) in lymphocytes' nuclei were stained immunocytochemically using the gamma-H2AX protein. Gamma-H2AX foci inside each nucleus were counted in 300 irradiated as well as 50 non-irradiated lymphocytes per patient. In addition, lymphocytes of 5 volunteer subjects were irradiated externally at different doses and processed under same conditions as the patients' lymphocytes in order to generate a calibration-line. This calibration-line assigns dose-value to mean number of gamma-H2AX foci/ nucleus. So the dose distributions in patients' lymphocytes were determined regarding to the gamma-H2AX foci distribution. With this information a cumulative dose-lymphocyte-histogram (DLH) was generated. Visualized distribution of gamma-H2AX foci, correspondingly dose per nucleus, was compared to the technical dose-volume-histogram (DVH), related to the whole body-volume. RESULTS: Measured in-vivo (DLH) and according to the physical treatment-planning (DVH), more lymphocytes resulted with low-dose exposure (< 20% of the applied dose) and significantly fewer lymphocytes with middle-dose exposure (30%-60%) during Step-and-Shoot-IMRT, compared to conventional 3D conformal radiotherapy. The high-dose exposure (> 80%) was equal in both radiation techniques. The mean number of gamma-H2AX foci per lymphocyte was 0.49 (3D) and 0.47 (SSIMRT) without significant difference. CONCLUSIONS: In-vivo measurement of the dose distribution within patients' lymphocytes can be performed by detecting gamma-H2AX foci. In case of 3D and SSIMRT, the results of this method correlate with the physical calculated total body dose-distribution, but cannot be interpreted unrestrictedly due to the blood circulation. One possible application of the present method could be in radiation-protection for in-vivo dose estimation after accidental exposure to radiation. BioMed Central 2011-06-07 /pmc/articles/PMC3121605/ /pubmed/21649920 http://dx.doi.org/10.1186/1748-717X-6-62 Text en Copyright ©2011 Zwicker et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Zwicker, Felix
Swartman, Benedict
Sterzing, Florian
Major, Gerald
Weber, Klaus-Josef
Huber, Peter E
Thieke, Christian
Debus, Jürgen
Herfarth, Klaus
Biological in-vivo measurement of dose distribution in patients' lymphocytes by gamma-H2AX immunofluorescence staining: 3D conformal- vs. step-and-shoot IMRT of the prostate gland
title Biological in-vivo measurement of dose distribution in patients' lymphocytes by gamma-H2AX immunofluorescence staining: 3D conformal- vs. step-and-shoot IMRT of the prostate gland
title_full Biological in-vivo measurement of dose distribution in patients' lymphocytes by gamma-H2AX immunofluorescence staining: 3D conformal- vs. step-and-shoot IMRT of the prostate gland
title_fullStr Biological in-vivo measurement of dose distribution in patients' lymphocytes by gamma-H2AX immunofluorescence staining: 3D conformal- vs. step-and-shoot IMRT of the prostate gland
title_full_unstemmed Biological in-vivo measurement of dose distribution in patients' lymphocytes by gamma-H2AX immunofluorescence staining: 3D conformal- vs. step-and-shoot IMRT of the prostate gland
title_short Biological in-vivo measurement of dose distribution in patients' lymphocytes by gamma-H2AX immunofluorescence staining: 3D conformal- vs. step-and-shoot IMRT of the prostate gland
title_sort biological in-vivo measurement of dose distribution in patients' lymphocytes by gamma-h2ax immunofluorescence staining: 3d conformal- vs. step-and-shoot imrt of the prostate gland
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3121605/
https://www.ncbi.nlm.nih.gov/pubmed/21649920
http://dx.doi.org/10.1186/1748-717X-6-62
work_keys_str_mv AT zwickerfelix biologicalinvivomeasurementofdosedistributioninpatientslymphocytesbygammah2aximmunofluorescencestaining3dconformalvsstepandshootimrtoftheprostategland
AT swartmanbenedict biologicalinvivomeasurementofdosedistributioninpatientslymphocytesbygammah2aximmunofluorescencestaining3dconformalvsstepandshootimrtoftheprostategland
AT sterzingflorian biologicalinvivomeasurementofdosedistributioninpatientslymphocytesbygammah2aximmunofluorescencestaining3dconformalvsstepandshootimrtoftheprostategland
AT majorgerald biologicalinvivomeasurementofdosedistributioninpatientslymphocytesbygammah2aximmunofluorescencestaining3dconformalvsstepandshootimrtoftheprostategland
AT weberklausjosef biologicalinvivomeasurementofdosedistributioninpatientslymphocytesbygammah2aximmunofluorescencestaining3dconformalvsstepandshootimrtoftheprostategland
AT huberpetere biologicalinvivomeasurementofdosedistributioninpatientslymphocytesbygammah2aximmunofluorescencestaining3dconformalvsstepandshootimrtoftheprostategland
AT thiekechristian biologicalinvivomeasurementofdosedistributioninpatientslymphocytesbygammah2aximmunofluorescencestaining3dconformalvsstepandshootimrtoftheprostategland
AT debusjurgen biologicalinvivomeasurementofdosedistributioninpatientslymphocytesbygammah2aximmunofluorescencestaining3dconformalvsstepandshootimrtoftheprostategland
AT herfarthklaus biologicalinvivomeasurementofdosedistributioninpatientslymphocytesbygammah2aximmunofluorescencestaining3dconformalvsstepandshootimrtoftheprostategland