Very Late Stent Thrombosis of Sirolimus-eluting Stent 59 Months After Implantation: A First Report from The Middle-East and Review of Literature
Very late stent thrombosis occurs more frequently with drug-eluting stents and tends to occur despite dual antiplatelet therapy or after long periods of clopidogrel discontinuation. Stent thrombosis commonly presents with myocardial infarction or death. We report a 41-year-old Arab male with very la...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications Pvt Ltd
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3123512/ https://www.ncbi.nlm.nih.gov/pubmed/21731805 http://dx.doi.org/10.4103/1995-705X.81557 |
_version_ | 1782206984962965504 |
---|---|
author | Panduranga, Prashanth Al-Mukhaini, Mohammed |
author_facet | Panduranga, Prashanth Al-Mukhaini, Mohammed |
author_sort | Panduranga, Prashanth |
collection | PubMed |
description | Very late stent thrombosis occurs more frequently with drug-eluting stents and tends to occur despite dual antiplatelet therapy or after long periods of clopidogrel discontinuation. Stent thrombosis commonly presents with myocardial infarction or death. We report a 41-year-old Arab male with very late stent thrombosis after 59 months of sirolimus-eluting stent implantation and –49 months after clopidogrel discontinuation despite aspirin continuation, presenting with exertional angina. He underwent successful percutaneous coronary intervention. This case underlines the need for novel stent designs as well as newer therapeutic strategies in preventing very late stent thrombosis among patients receiving drug-eluting stents. |
format | Online Article Text |
id | pubmed-3123512 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Medknow Publications Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-31235122011-07-01 Very Late Stent Thrombosis of Sirolimus-eluting Stent 59 Months After Implantation: A First Report from The Middle-East and Review of Literature Panduranga, Prashanth Al-Mukhaini, Mohammed Heart Views Case Report Very late stent thrombosis occurs more frequently with drug-eluting stents and tends to occur despite dual antiplatelet therapy or after long periods of clopidogrel discontinuation. Stent thrombosis commonly presents with myocardial infarction or death. We report a 41-year-old Arab male with very late stent thrombosis after 59 months of sirolimus-eluting stent implantation and –49 months after clopidogrel discontinuation despite aspirin continuation, presenting with exertional angina. He underwent successful percutaneous coronary intervention. This case underlines the need for novel stent designs as well as newer therapeutic strategies in preventing very late stent thrombosis among patients receiving drug-eluting stents. Medknow Publications Pvt Ltd 2011 /pmc/articles/PMC3123512/ /pubmed/21731805 http://dx.doi.org/10.4103/1995-705X.81557 Text en © Heart Views http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Panduranga, Prashanth Al-Mukhaini, Mohammed Very Late Stent Thrombosis of Sirolimus-eluting Stent 59 Months After Implantation: A First Report from The Middle-East and Review of Literature |
title | Very Late Stent Thrombosis of Sirolimus-eluting Stent 59 Months After Implantation: A First Report from The Middle-East and Review of Literature |
title_full | Very Late Stent Thrombosis of Sirolimus-eluting Stent 59 Months After Implantation: A First Report from The Middle-East and Review of Literature |
title_fullStr | Very Late Stent Thrombosis of Sirolimus-eluting Stent 59 Months After Implantation: A First Report from The Middle-East and Review of Literature |
title_full_unstemmed | Very Late Stent Thrombosis of Sirolimus-eluting Stent 59 Months After Implantation: A First Report from The Middle-East and Review of Literature |
title_short | Very Late Stent Thrombosis of Sirolimus-eluting Stent 59 Months After Implantation: A First Report from The Middle-East and Review of Literature |
title_sort | very late stent thrombosis of sirolimus-eluting stent 59 months after implantation: a first report from the middle-east and review of literature |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3123512/ https://www.ncbi.nlm.nih.gov/pubmed/21731805 http://dx.doi.org/10.4103/1995-705X.81557 |
work_keys_str_mv | AT pandurangaprashanth verylatestentthrombosisofsirolimuselutingstent59monthsafterimplantationafirstreportfromthemiddleeastandreviewofliterature AT almukhainimohammed verylatestentthrombosisofsirolimuselutingstent59monthsafterimplantationafirstreportfromthemiddleeastandreviewofliterature |