Cargando…

Automatic Polyp Detection in Pillcam Colon 2 Capsule Images and Videos: Preliminary Feasibility Report

Background. The aim of this work is to present an automatic colorectal polyp detection scheme for capsule endoscopy. Methods. PillCam COLON2 capsule-based images and videos were used in our study. The database consists of full exam videos from five patients. The algorithm is based on the assumption...

Descripción completa

Detalles Bibliográficos
Autores principales: Figueiredo, Pedro N., Figueiredo, Isabel N., Prasath, Surya, Tsai, Richard
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3124127/
https://www.ncbi.nlm.nih.gov/pubmed/21747647
http://dx.doi.org/10.1155/2011/182435
_version_ 1782207045334728704
author Figueiredo, Pedro N.
Figueiredo, Isabel N.
Prasath, Surya
Tsai, Richard
author_facet Figueiredo, Pedro N.
Figueiredo, Isabel N.
Prasath, Surya
Tsai, Richard
author_sort Figueiredo, Pedro N.
collection PubMed
description Background. The aim of this work is to present an automatic colorectal polyp detection scheme for capsule endoscopy. Methods. PillCam COLON2 capsule-based images and videos were used in our study. The database consists of full exam videos from five patients. The algorithm is based on the assumption that the polyps show up as a protrusion in the captured images and is expressed by means of a P-value, defined by geometrical features. Results. Seventeen PillCam COLON2 capsule videos are included, containing frames with polyps, flat lesions, diverticula, bubbles, and trash liquids. Polyps larger than 1 cm express a P-value higher than 2000, and 80% of the polyps show a P-value higher than 500. Diverticula, bubbles, trash liquids, and flat lesions were correctly interpreted by the algorithm as nonprotruding images. Conclusions. These preliminary results suggest that the proposed geometry-based polyp detection scheme works well, not only by allowing the detection of polyps but also by differentiating them from nonprotruding images found in the films.
format Online
Article
Text
id pubmed-3124127
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-31241272011-07-11 Automatic Polyp Detection in Pillcam Colon 2 Capsule Images and Videos: Preliminary Feasibility Report Figueiredo, Pedro N. Figueiredo, Isabel N. Prasath, Surya Tsai, Richard Diagn Ther Endosc Research Article Background. The aim of this work is to present an automatic colorectal polyp detection scheme for capsule endoscopy. Methods. PillCam COLON2 capsule-based images and videos were used in our study. The database consists of full exam videos from five patients. The algorithm is based on the assumption that the polyps show up as a protrusion in the captured images and is expressed by means of a P-value, defined by geometrical features. Results. Seventeen PillCam COLON2 capsule videos are included, containing frames with polyps, flat lesions, diverticula, bubbles, and trash liquids. Polyps larger than 1 cm express a P-value higher than 2000, and 80% of the polyps show a P-value higher than 500. Diverticula, bubbles, trash liquids, and flat lesions were correctly interpreted by the algorithm as nonprotruding images. Conclusions. These preliminary results suggest that the proposed geometry-based polyp detection scheme works well, not only by allowing the detection of polyps but also by differentiating them from nonprotruding images found in the films. Hindawi Publishing Corporation 2011 2011-05-22 /pmc/articles/PMC3124127/ /pubmed/21747647 http://dx.doi.org/10.1155/2011/182435 Text en Copyright © 2011 Pedro N. Figueiredo et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Figueiredo, Pedro N.
Figueiredo, Isabel N.
Prasath, Surya
Tsai, Richard
Automatic Polyp Detection in Pillcam Colon 2 Capsule Images and Videos: Preliminary Feasibility Report
title Automatic Polyp Detection in Pillcam Colon 2 Capsule Images and Videos: Preliminary Feasibility Report
title_full Automatic Polyp Detection in Pillcam Colon 2 Capsule Images and Videos: Preliminary Feasibility Report
title_fullStr Automatic Polyp Detection in Pillcam Colon 2 Capsule Images and Videos: Preliminary Feasibility Report
title_full_unstemmed Automatic Polyp Detection in Pillcam Colon 2 Capsule Images and Videos: Preliminary Feasibility Report
title_short Automatic Polyp Detection in Pillcam Colon 2 Capsule Images and Videos: Preliminary Feasibility Report
title_sort automatic polyp detection in pillcam colon 2 capsule images and videos: preliminary feasibility report
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3124127/
https://www.ncbi.nlm.nih.gov/pubmed/21747647
http://dx.doi.org/10.1155/2011/182435
work_keys_str_mv AT figueiredopedron automaticpolypdetectioninpillcamcolon2capsuleimagesandvideospreliminaryfeasibilityreport
AT figueiredoisabeln automaticpolypdetectioninpillcamcolon2capsuleimagesandvideospreliminaryfeasibilityreport
AT prasathsurya automaticpolypdetectioninpillcamcolon2capsuleimagesandvideospreliminaryfeasibilityreport
AT tsairichard automaticpolypdetectioninpillcamcolon2capsuleimagesandvideospreliminaryfeasibilityreport