Cargando…
Clinical utility of tibial motor and sensory nerve conduction studies with motor recording from the flexor hallucis brevis: a methodological and reliability study
BACKGROUND: Standard tibial motor nerve conduction measures are established with recording from the abductor hallucis. This technique is often technically challenging and clinicians have difficulty interpreting the information particularly in the short segment needed to assess focal tibial nerve ent...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3125324/ https://www.ncbi.nlm.nih.gov/pubmed/21609432 http://dx.doi.org/10.1186/1757-1146-4-14 |
_version_ | 1782207207100645376 |
---|---|
author | Galloway, Kathleen M Lester, Mark E Evans, Rachel K |
author_facet | Galloway, Kathleen M Lester, Mark E Evans, Rachel K |
author_sort | Galloway, Kathleen M |
collection | PubMed |
description | BACKGROUND: Standard tibial motor nerve conduction measures are established with recording from the abductor hallucis. This technique is often technically challenging and clinicians have difficulty interpreting the information particularly in the short segment needed to assess focal tibial nerve entrapment at the medial ankle as occurs in posterior tarsal tunnel syndrome. The flexor hallucis brevis (FHB) has been described as an alternative site for recording tibial nerve function in those with posterior tarsal tunnel syndrome. Normative data has not been established for this technique. This pilot study describes the technique in detail. In addition we provide reference values for medial and lateral plantar orthodromic sensory measures and assessed intrarater reliability for all measures. METHODS: Eighty healthy female participants took part, and 39 returned for serial testing at 4 time points. Mean values ± SD were recorded for nerve conduction measures, and coefficient of variation as well as intraclass correlation coefficients (ICC) were calculated. RESULTS: Motor latency, amplitude and velocity values for the FHB were 4.1 ± 0.9 msec, 8.0 ± 3.0 mV and 45.6 ± 3.4 m/s, respectively. Sensory latencies, amplitudes, and velocities, respectively, were 2.8 ± 0.3 msec, 26.7 ± 10.1 μV, and 41.4 ± 3.5 m/s for the medial plantar nerve and 3.2 ± 0.5 msec, 13.3 ± 4.7 μV, and 44.3 ± 4.0 msec for the lateral plantar nerve. All values demonstrated significant ICC values (P ≤ 0.007). CONCLUSION: Motor recording from the FHB provides technically clear waveforms that allow for an improved ability to assess tibial nerve function in the short segments used to assess tarsal tunnel syndrome. The reported means will begin to establish normal values for this technique. |
format | Online Article Text |
id | pubmed-3125324 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-31253242011-06-29 Clinical utility of tibial motor and sensory nerve conduction studies with motor recording from the flexor hallucis brevis: a methodological and reliability study Galloway, Kathleen M Lester, Mark E Evans, Rachel K J Foot Ankle Res Methodology Article BACKGROUND: Standard tibial motor nerve conduction measures are established with recording from the abductor hallucis. This technique is often technically challenging and clinicians have difficulty interpreting the information particularly in the short segment needed to assess focal tibial nerve entrapment at the medial ankle as occurs in posterior tarsal tunnel syndrome. The flexor hallucis brevis (FHB) has been described as an alternative site for recording tibial nerve function in those with posterior tarsal tunnel syndrome. Normative data has not been established for this technique. This pilot study describes the technique in detail. In addition we provide reference values for medial and lateral plantar orthodromic sensory measures and assessed intrarater reliability for all measures. METHODS: Eighty healthy female participants took part, and 39 returned for serial testing at 4 time points. Mean values ± SD were recorded for nerve conduction measures, and coefficient of variation as well as intraclass correlation coefficients (ICC) were calculated. RESULTS: Motor latency, amplitude and velocity values for the FHB were 4.1 ± 0.9 msec, 8.0 ± 3.0 mV and 45.6 ± 3.4 m/s, respectively. Sensory latencies, amplitudes, and velocities, respectively, were 2.8 ± 0.3 msec, 26.7 ± 10.1 μV, and 41.4 ± 3.5 m/s for the medial plantar nerve and 3.2 ± 0.5 msec, 13.3 ± 4.7 μV, and 44.3 ± 4.0 msec for the lateral plantar nerve. All values demonstrated significant ICC values (P ≤ 0.007). CONCLUSION: Motor recording from the FHB provides technically clear waveforms that allow for an improved ability to assess tibial nerve function in the short segments used to assess tarsal tunnel syndrome. The reported means will begin to establish normal values for this technique. BioMed Central 2011-05-24 /pmc/articles/PMC3125324/ /pubmed/21609432 http://dx.doi.org/10.1186/1757-1146-4-14 Text en Copyright ©2011 Galloway et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Methodology Article Galloway, Kathleen M Lester, Mark E Evans, Rachel K Clinical utility of tibial motor and sensory nerve conduction studies with motor recording from the flexor hallucis brevis: a methodological and reliability study |
title | Clinical utility of tibial motor and sensory nerve conduction studies with motor recording from the flexor hallucis brevis: a methodological and reliability study |
title_full | Clinical utility of tibial motor and sensory nerve conduction studies with motor recording from the flexor hallucis brevis: a methodological and reliability study |
title_fullStr | Clinical utility of tibial motor and sensory nerve conduction studies with motor recording from the flexor hallucis brevis: a methodological and reliability study |
title_full_unstemmed | Clinical utility of tibial motor and sensory nerve conduction studies with motor recording from the flexor hallucis brevis: a methodological and reliability study |
title_short | Clinical utility of tibial motor and sensory nerve conduction studies with motor recording from the flexor hallucis brevis: a methodological and reliability study |
title_sort | clinical utility of tibial motor and sensory nerve conduction studies with motor recording from the flexor hallucis brevis: a methodological and reliability study |
topic | Methodology Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3125324/ https://www.ncbi.nlm.nih.gov/pubmed/21609432 http://dx.doi.org/10.1186/1757-1146-4-14 |
work_keys_str_mv | AT gallowaykathleenm clinicalutilityoftibialmotorandsensorynerveconductionstudieswithmotorrecordingfromtheflexorhallucisbrevisamethodologicalandreliabilitystudy AT lestermarke clinicalutilityoftibialmotorandsensorynerveconductionstudieswithmotorrecordingfromtheflexorhallucisbrevisamethodologicalandreliabilitystudy AT evansrachelk clinicalutilityoftibialmotorandsensorynerveconductionstudieswithmotorrecordingfromtheflexorhallucisbrevisamethodologicalandreliabilitystudy |