Cargando…

Clinical utility of tibial motor and sensory nerve conduction studies with motor recording from the flexor hallucis brevis: a methodological and reliability study

BACKGROUND: Standard tibial motor nerve conduction measures are established with recording from the abductor hallucis. This technique is often technically challenging and clinicians have difficulty interpreting the information particularly in the short segment needed to assess focal tibial nerve ent...

Descripción completa

Detalles Bibliográficos
Autores principales: Galloway, Kathleen M, Lester, Mark E, Evans, Rachel K
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3125324/
https://www.ncbi.nlm.nih.gov/pubmed/21609432
http://dx.doi.org/10.1186/1757-1146-4-14
_version_ 1782207207100645376
author Galloway, Kathleen M
Lester, Mark E
Evans, Rachel K
author_facet Galloway, Kathleen M
Lester, Mark E
Evans, Rachel K
author_sort Galloway, Kathleen M
collection PubMed
description BACKGROUND: Standard tibial motor nerve conduction measures are established with recording from the abductor hallucis. This technique is often technically challenging and clinicians have difficulty interpreting the information particularly in the short segment needed to assess focal tibial nerve entrapment at the medial ankle as occurs in posterior tarsal tunnel syndrome. The flexor hallucis brevis (FHB) has been described as an alternative site for recording tibial nerve function in those with posterior tarsal tunnel syndrome. Normative data has not been established for this technique. This pilot study describes the technique in detail. In addition we provide reference values for medial and lateral plantar orthodromic sensory measures and assessed intrarater reliability for all measures. METHODS: Eighty healthy female participants took part, and 39 returned for serial testing at 4 time points. Mean values ± SD were recorded for nerve conduction measures, and coefficient of variation as well as intraclass correlation coefficients (ICC) were calculated. RESULTS: Motor latency, amplitude and velocity values for the FHB were 4.1 ± 0.9 msec, 8.0 ± 3.0 mV and 45.6 ± 3.4 m/s, respectively. Sensory latencies, amplitudes, and velocities, respectively, were 2.8 ± 0.3 msec, 26.7 ± 10.1 μV, and 41.4 ± 3.5 m/s for the medial plantar nerve and 3.2 ± 0.5 msec, 13.3 ± 4.7 μV, and 44.3 ± 4.0 msec for the lateral plantar nerve. All values demonstrated significant ICC values (P ≤ 0.007). CONCLUSION: Motor recording from the FHB provides technically clear waveforms that allow for an improved ability to assess tibial nerve function in the short segments used to assess tarsal tunnel syndrome. The reported means will begin to establish normal values for this technique.
format Online
Article
Text
id pubmed-3125324
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-31253242011-06-29 Clinical utility of tibial motor and sensory nerve conduction studies with motor recording from the flexor hallucis brevis: a methodological and reliability study Galloway, Kathleen M Lester, Mark E Evans, Rachel K J Foot Ankle Res Methodology Article BACKGROUND: Standard tibial motor nerve conduction measures are established with recording from the abductor hallucis. This technique is often technically challenging and clinicians have difficulty interpreting the information particularly in the short segment needed to assess focal tibial nerve entrapment at the medial ankle as occurs in posterior tarsal tunnel syndrome. The flexor hallucis brevis (FHB) has been described as an alternative site for recording tibial nerve function in those with posterior tarsal tunnel syndrome. Normative data has not been established for this technique. This pilot study describes the technique in detail. In addition we provide reference values for medial and lateral plantar orthodromic sensory measures and assessed intrarater reliability for all measures. METHODS: Eighty healthy female participants took part, and 39 returned for serial testing at 4 time points. Mean values ± SD were recorded for nerve conduction measures, and coefficient of variation as well as intraclass correlation coefficients (ICC) were calculated. RESULTS: Motor latency, amplitude and velocity values for the FHB were 4.1 ± 0.9 msec, 8.0 ± 3.0 mV and 45.6 ± 3.4 m/s, respectively. Sensory latencies, amplitudes, and velocities, respectively, were 2.8 ± 0.3 msec, 26.7 ± 10.1 μV, and 41.4 ± 3.5 m/s for the medial plantar nerve and 3.2 ± 0.5 msec, 13.3 ± 4.7 μV, and 44.3 ± 4.0 msec for the lateral plantar nerve. All values demonstrated significant ICC values (P ≤ 0.007). CONCLUSION: Motor recording from the FHB provides technically clear waveforms that allow for an improved ability to assess tibial nerve function in the short segments used to assess tarsal tunnel syndrome. The reported means will begin to establish normal values for this technique. BioMed Central 2011-05-24 /pmc/articles/PMC3125324/ /pubmed/21609432 http://dx.doi.org/10.1186/1757-1146-4-14 Text en Copyright ©2011 Galloway et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Methodology Article
Galloway, Kathleen M
Lester, Mark E
Evans, Rachel K
Clinical utility of tibial motor and sensory nerve conduction studies with motor recording from the flexor hallucis brevis: a methodological and reliability study
title Clinical utility of tibial motor and sensory nerve conduction studies with motor recording from the flexor hallucis brevis: a methodological and reliability study
title_full Clinical utility of tibial motor and sensory nerve conduction studies with motor recording from the flexor hallucis brevis: a methodological and reliability study
title_fullStr Clinical utility of tibial motor and sensory nerve conduction studies with motor recording from the flexor hallucis brevis: a methodological and reliability study
title_full_unstemmed Clinical utility of tibial motor and sensory nerve conduction studies with motor recording from the flexor hallucis brevis: a methodological and reliability study
title_short Clinical utility of tibial motor and sensory nerve conduction studies with motor recording from the flexor hallucis brevis: a methodological and reliability study
title_sort clinical utility of tibial motor and sensory nerve conduction studies with motor recording from the flexor hallucis brevis: a methodological and reliability study
topic Methodology Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3125324/
https://www.ncbi.nlm.nih.gov/pubmed/21609432
http://dx.doi.org/10.1186/1757-1146-4-14
work_keys_str_mv AT gallowaykathleenm clinicalutilityoftibialmotorandsensorynerveconductionstudieswithmotorrecordingfromtheflexorhallucisbrevisamethodologicalandreliabilitystudy
AT lestermarke clinicalutilityoftibialmotorandsensorynerveconductionstudieswithmotorrecordingfromtheflexorhallucisbrevisamethodologicalandreliabilitystudy
AT evansrachelk clinicalutilityoftibialmotorandsensorynerveconductionstudieswithmotorrecordingfromtheflexorhallucisbrevisamethodologicalandreliabilitystudy