Cargando…

Evaluation of biolistic gene transfer methods in vivo using non-invasive bioluminescent imaging techniques

BACKGROUND: Gene therapy continues to hold great potential for treating many different types of disease and dysfunction. Safe and efficient techniques for gene transfer and expression in vivo are needed to enable gene therapeutic strategies to be effective in patients. Currently, the most commonly u...

Descripción completa

Detalles Bibliográficos
Autores principales: Xia, Jixiang, Martinez, Angela, Daniell, Henry, Ebert, Steven N
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3125329/
https://www.ncbi.nlm.nih.gov/pubmed/21635760
http://dx.doi.org/10.1186/1472-6750-11-62
_version_ 1782207208243593216
author Xia, Jixiang
Martinez, Angela
Daniell, Henry
Ebert, Steven N
author_facet Xia, Jixiang
Martinez, Angela
Daniell, Henry
Ebert, Steven N
author_sort Xia, Jixiang
collection PubMed
description BACKGROUND: Gene therapy continues to hold great potential for treating many different types of disease and dysfunction. Safe and efficient techniques for gene transfer and expression in vivo are needed to enable gene therapeutic strategies to be effective in patients. Currently, the most commonly used methods employ replication-defective viral vectors for gene transfer, while physical gene transfer methods such as biolistic-mediated ("gene-gun") delivery to target tissues have not been as extensively explored. In the present study, we evaluated the efficacy of biolistic gene transfer techniques in vivo using non-invasive bioluminescent imaging (BLI) methods. RESULTS: Plasmid DNA carrying the firefly luciferase (LUC) reporter gene under the control of the human Cytomegalovirus (CMV) promoter/enhancer was transfected into mouse skin and liver using biolistic methods. The plasmids were coupled to gold microspheres (1 μm diameter) using different DNA Loading Ratios (DLRs), and "shot" into target tissues using a helium-driven gene gun. The optimal DLR was found to be in the range of 4-10. Bioluminescence was measured using an In Vivo Imaging System (IVIS-50) at various time-points following transfer. Biolistic gene transfer to mouse skin produced peak reporter gene expression one day after transfer. Expression remained detectable through four days, but declined to undetectable levels by six days following gene transfer. Maximum depth of tissue penetration following biolistic transfer to abdominal skin was 200-300 μm. Similarly, biolistic gene transfer to mouse liver in vivo also produced peak early expression followed by a decline over time. In contrast to skin, however, liver expression of the reporter gene was relatively stable 4-8 days post-biolistic gene transfer, and remained detectable for nearly two weeks. CONCLUSIONS: The use of bioluminescence imaging techniques enabled efficient evaluation of reporter gene expression in vivo. Our results demonstrate that different tissues show different expression kinetics following gene transfer of the same reporter plasmid to different mouse tissues in vivo. We evaluated superficial (skin) and abdominal organ (liver) targets, and found that reporter gene expression peaked within the first two days post-transfer in each case, but declined most rapidly in the skin (3-4 days) compared to liver (10-14 days). This information is essential for designing effective gene therapy strategies in different target tissues.
format Online
Article
Text
id pubmed-3125329
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-31253292011-06-29 Evaluation of biolistic gene transfer methods in vivo using non-invasive bioluminescent imaging techniques Xia, Jixiang Martinez, Angela Daniell, Henry Ebert, Steven N BMC Biotechnol Research Article BACKGROUND: Gene therapy continues to hold great potential for treating many different types of disease and dysfunction. Safe and efficient techniques for gene transfer and expression in vivo are needed to enable gene therapeutic strategies to be effective in patients. Currently, the most commonly used methods employ replication-defective viral vectors for gene transfer, while physical gene transfer methods such as biolistic-mediated ("gene-gun") delivery to target tissues have not been as extensively explored. In the present study, we evaluated the efficacy of biolistic gene transfer techniques in vivo using non-invasive bioluminescent imaging (BLI) methods. RESULTS: Plasmid DNA carrying the firefly luciferase (LUC) reporter gene under the control of the human Cytomegalovirus (CMV) promoter/enhancer was transfected into mouse skin and liver using biolistic methods. The plasmids were coupled to gold microspheres (1 μm diameter) using different DNA Loading Ratios (DLRs), and "shot" into target tissues using a helium-driven gene gun. The optimal DLR was found to be in the range of 4-10. Bioluminescence was measured using an In Vivo Imaging System (IVIS-50) at various time-points following transfer. Biolistic gene transfer to mouse skin produced peak reporter gene expression one day after transfer. Expression remained detectable through four days, but declined to undetectable levels by six days following gene transfer. Maximum depth of tissue penetration following biolistic transfer to abdominal skin was 200-300 μm. Similarly, biolistic gene transfer to mouse liver in vivo also produced peak early expression followed by a decline over time. In contrast to skin, however, liver expression of the reporter gene was relatively stable 4-8 days post-biolistic gene transfer, and remained detectable for nearly two weeks. CONCLUSIONS: The use of bioluminescence imaging techniques enabled efficient evaluation of reporter gene expression in vivo. Our results demonstrate that different tissues show different expression kinetics following gene transfer of the same reporter plasmid to different mouse tissues in vivo. We evaluated superficial (skin) and abdominal organ (liver) targets, and found that reporter gene expression peaked within the first two days post-transfer in each case, but declined most rapidly in the skin (3-4 days) compared to liver (10-14 days). This information is essential for designing effective gene therapy strategies in different target tissues. BioMed Central 2011-06-02 /pmc/articles/PMC3125329/ /pubmed/21635760 http://dx.doi.org/10.1186/1472-6750-11-62 Text en Copyright ©2011 Xia et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Xia, Jixiang
Martinez, Angela
Daniell, Henry
Ebert, Steven N
Evaluation of biolistic gene transfer methods in vivo using non-invasive bioluminescent imaging techniques
title Evaluation of biolistic gene transfer methods in vivo using non-invasive bioluminescent imaging techniques
title_full Evaluation of biolistic gene transfer methods in vivo using non-invasive bioluminescent imaging techniques
title_fullStr Evaluation of biolistic gene transfer methods in vivo using non-invasive bioluminescent imaging techniques
title_full_unstemmed Evaluation of biolistic gene transfer methods in vivo using non-invasive bioluminescent imaging techniques
title_short Evaluation of biolistic gene transfer methods in vivo using non-invasive bioluminescent imaging techniques
title_sort evaluation of biolistic gene transfer methods in vivo using non-invasive bioluminescent imaging techniques
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3125329/
https://www.ncbi.nlm.nih.gov/pubmed/21635760
http://dx.doi.org/10.1186/1472-6750-11-62
work_keys_str_mv AT xiajixiang evaluationofbiolisticgenetransfermethodsinvivousingnoninvasivebioluminescentimagingtechniques
AT martinezangela evaluationofbiolisticgenetransfermethodsinvivousingnoninvasivebioluminescentimagingtechniques
AT daniellhenry evaluationofbiolisticgenetransfermethodsinvivousingnoninvasivebioluminescentimagingtechniques
AT ebertstevenn evaluationofbiolisticgenetransfermethodsinvivousingnoninvasivebioluminescentimagingtechniques