Cargando…

A comparison of dose-response characteristics of four NTCP models using outcomes of radiation-induced optic neuropathy and retinopathy

BACKGROUND: Biological models are used to relate the outcome of radiation therapy to dose distribution. As use of biological models in treatment planning expands, uncertainties associated with the use of specific models for predicting outcomes should be understood and quantified. In particular, the...

Descripción completa

Detalles Bibliográficos
Autores principales: Moiseenko, Vitali, Song, William Y, Mell, Loren K, Bhandare, Niranjan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3127783/
https://www.ncbi.nlm.nih.gov/pubmed/21645390
http://dx.doi.org/10.1186/1748-717X-6-61
_version_ 1782207370913382400
author Moiseenko, Vitali
Song, William Y
Mell, Loren K
Bhandare, Niranjan
author_facet Moiseenko, Vitali
Song, William Y
Mell, Loren K
Bhandare, Niranjan
author_sort Moiseenko, Vitali
collection PubMed
description BACKGROUND: Biological models are used to relate the outcome of radiation therapy to dose distribution. As use of biological models in treatment planning expands, uncertainties associated with the use of specific models for predicting outcomes should be understood and quantified. In particular, the question to what extent model predictions are data-driven or dependent on the choice of the model has to be explored. METHODS: Four dose-response models--logistic, log-logistic, Poisson-based and probit--were tested for their ability and consistency in describing dose-response data for radiation-induced optic neuropathy (RION) and retinopathy (RIRP). Dose to the optic nerves was specified as the minimum dose, D(min), received by any segment of the organ to which the damage was diagnosed by ophthalmologic evaluation. For retinopathy, the dose to the retina was specified as the highest isodose covering at least 1/3 of the retinal surface (D(33%)) that geometrically covered the observed retinal damage. Data on both complications were modeled separately for patients treated once daily and twice daily. Model parameters D(50 )and γ and corresponding confidence intervals were obtained using maximum-likelihood method. RESULTS: Model parameters were reasonably consistent for RION data for patients treated once daily, D(50 )ranging from 94.2 to 104.7 Gy and γ from 0.88 to 1.41. Similar consistency was seen for RIRP data which span a broad range of complication incidence, with D(50 )from 72.2 to 75.0 Gy and γ from 1.51 to 2.16 for patients treated twice daily; 72.2-74.0 Gy and 0.84-1.20 for patients treated once daily. However, large variations were observed for RION in patients treated twice daily, D(50 )from 96.3 to 125.2 Gy and γ from 0.80 to 1.56. Complication incidence in this dataset in any dose group did not exceed 20%. CONCLUSIONS: For the considered data sets, the log-logistic model tends to lead to larger D(50 )and lower γ compared to other models for all datasets. Statements regarding normal tissue radiosensitivity and steepness of dose-response, based on model parameters, should be made with caution as the latter are not only model-dependent but also sensitive to the range of complication incidence exhibited by clinical data.
format Online
Article
Text
id pubmed-3127783
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-31277832011-07-01 A comparison of dose-response characteristics of four NTCP models using outcomes of radiation-induced optic neuropathy and retinopathy Moiseenko, Vitali Song, William Y Mell, Loren K Bhandare, Niranjan Radiat Oncol Research BACKGROUND: Biological models are used to relate the outcome of radiation therapy to dose distribution. As use of biological models in treatment planning expands, uncertainties associated with the use of specific models for predicting outcomes should be understood and quantified. In particular, the question to what extent model predictions are data-driven or dependent on the choice of the model has to be explored. METHODS: Four dose-response models--logistic, log-logistic, Poisson-based and probit--were tested for their ability and consistency in describing dose-response data for radiation-induced optic neuropathy (RION) and retinopathy (RIRP). Dose to the optic nerves was specified as the minimum dose, D(min), received by any segment of the organ to which the damage was diagnosed by ophthalmologic evaluation. For retinopathy, the dose to the retina was specified as the highest isodose covering at least 1/3 of the retinal surface (D(33%)) that geometrically covered the observed retinal damage. Data on both complications were modeled separately for patients treated once daily and twice daily. Model parameters D(50 )and γ and corresponding confidence intervals were obtained using maximum-likelihood method. RESULTS: Model parameters were reasonably consistent for RION data for patients treated once daily, D(50 )ranging from 94.2 to 104.7 Gy and γ from 0.88 to 1.41. Similar consistency was seen for RIRP data which span a broad range of complication incidence, with D(50 )from 72.2 to 75.0 Gy and γ from 1.51 to 2.16 for patients treated twice daily; 72.2-74.0 Gy and 0.84-1.20 for patients treated once daily. However, large variations were observed for RION in patients treated twice daily, D(50 )from 96.3 to 125.2 Gy and γ from 0.80 to 1.56. Complication incidence in this dataset in any dose group did not exceed 20%. CONCLUSIONS: For the considered data sets, the log-logistic model tends to lead to larger D(50 )and lower γ compared to other models for all datasets. Statements regarding normal tissue radiosensitivity and steepness of dose-response, based on model parameters, should be made with caution as the latter are not only model-dependent but also sensitive to the range of complication incidence exhibited by clinical data. BioMed Central 2011-06-06 /pmc/articles/PMC3127783/ /pubmed/21645390 http://dx.doi.org/10.1186/1748-717X-6-61 Text en Copyright ©2011 Moiseenko et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Moiseenko, Vitali
Song, William Y
Mell, Loren K
Bhandare, Niranjan
A comparison of dose-response characteristics of four NTCP models using outcomes of radiation-induced optic neuropathy and retinopathy
title A comparison of dose-response characteristics of four NTCP models using outcomes of radiation-induced optic neuropathy and retinopathy
title_full A comparison of dose-response characteristics of four NTCP models using outcomes of radiation-induced optic neuropathy and retinopathy
title_fullStr A comparison of dose-response characteristics of four NTCP models using outcomes of radiation-induced optic neuropathy and retinopathy
title_full_unstemmed A comparison of dose-response characteristics of four NTCP models using outcomes of radiation-induced optic neuropathy and retinopathy
title_short A comparison of dose-response characteristics of four NTCP models using outcomes of radiation-induced optic neuropathy and retinopathy
title_sort comparison of dose-response characteristics of four ntcp models using outcomes of radiation-induced optic neuropathy and retinopathy
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3127783/
https://www.ncbi.nlm.nih.gov/pubmed/21645390
http://dx.doi.org/10.1186/1748-717X-6-61
work_keys_str_mv AT moiseenkovitali acomparisonofdoseresponsecharacteristicsoffourntcpmodelsusingoutcomesofradiationinducedopticneuropathyandretinopathy
AT songwilliamy acomparisonofdoseresponsecharacteristicsoffourntcpmodelsusingoutcomesofradiationinducedopticneuropathyandretinopathy
AT melllorenk acomparisonofdoseresponsecharacteristicsoffourntcpmodelsusingoutcomesofradiationinducedopticneuropathyandretinopathy
AT bhandareniranjan acomparisonofdoseresponsecharacteristicsoffourntcpmodelsusingoutcomesofradiationinducedopticneuropathyandretinopathy
AT moiseenkovitali comparisonofdoseresponsecharacteristicsoffourntcpmodelsusingoutcomesofradiationinducedopticneuropathyandretinopathy
AT songwilliamy comparisonofdoseresponsecharacteristicsoffourntcpmodelsusingoutcomesofradiationinducedopticneuropathyandretinopathy
AT melllorenk comparisonofdoseresponsecharacteristicsoffourntcpmodelsusingoutcomesofradiationinducedopticneuropathyandretinopathy
AT bhandareniranjan comparisonofdoseresponsecharacteristicsoffourntcpmodelsusingoutcomesofradiationinducedopticneuropathyandretinopathy