Cavotricuspid Isthmus Anatomy Determines The Success Of Remote Controlled Magnetic Bidirectional Block: A Comparsion Between Magnetic 8-mm Solid Tip And 3.5-mm Magnetic Irrigated Tip Catheter
BACKGROUND: Cavotricuspid isthmus (CTI) anatomy is associated with a great inter-individual variability. The aim of this study was to compare the magnetic 8-mm tip catheter versus the novel 3.5-mm magnetic irrigated tip catheter in achieving bidirectional right atrial isthmus block and to evaluate t...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Indian Heart Rhythm Society
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3128816/ https://www.ncbi.nlm.nih.gov/pubmed/21760681 |
_version_ | 1782207474845089792 |
---|---|
author | Koektuerk, Buelent Chun, Julian KR Wissner, Erik Schmidt, Boris Ernst, Sabine Ouyang, Feifan Kuck, Karl-Heinz |
author_facet | Koektuerk, Buelent Chun, Julian KR Wissner, Erik Schmidt, Boris Ernst, Sabine Ouyang, Feifan Kuck, Karl-Heinz |
author_sort | Koektuerk, Buelent |
collection | PubMed |
description | BACKGROUND: Cavotricuspid isthmus (CTI) anatomy is associated with a great inter-individual variability. The aim of this study was to compare the magnetic 8-mm tip catheter versus the novel 3.5-mm magnetic irrigated tip catheter in achieving bidirectional right atrial isthmus block and to evaluate the impact of the underlying CTI anatomy on success rate. METHODS: A detailed remote controlled 3-dimensional electroanatomic (3D EA) right atrial reconstruction was performed using the magnetic navigation system with special emphasis to the CTI. CTI anatomy was evaluated utilizing the 3D EA map and classified into (A) simple (flat), (B) complex (pouch-like recess or concave shape) or (C) highly complex (pouch-like recess and concave shape). Patients were treated either with the magnetic 8-mm tip catheter (group I) or the open irrigated magnetic 3.5-mm tip catheter (group II). Primary endpoint was defined as acute bidirectional CTI block utilizing exclusively the remote controlled magnetic navigation system. Secondary endpoint was any procedure related complication and procedure time. RESULTS: In group I (n=10, 10 males, mean age: 65 ± 9 years) the primary endpoint was achieved in 80% (8/10 pts) requiring a median (Q1; Q3) RF application time of 37.1 min (22.8; 71.5) and a median (Q1;Q3) cumulative energy (CE) of 70.68 kJ (kilo Joule). (10.76;40.59). In group II (n=13, 10 males, mean age: 60 ± 7 years) the primary endpoint was achieved in 92 % (12/13) with a median (Q1; Q3) RF application time of 21.9 min (13.0; 27.0; p value=0.036) and a CE of 33.54 KJ (26.59; 49.22; p value=0.015). Variable CTI anatomy was identified for group I (type A: n=5 pts, type B: n=5 pts, type C: n=0 pts) and group for II (type A: n=4 pts, type B: n=7 pts, type C: n=2 pts). In group I magnetic ablation failure was associated with type B CTI anatomy (n=2 pts) and in group II with type C CTI (n=1). No procedure related complications were observed. CONCLUSION: Remote controlled catheter ablation of typical atrial flutter using the magnetic navigation system appears to be safe and feasible. CTI anatomy determines remote controlled magnetic ablation success. Use of the magnetic 3.5 mm irrigated tip catheter should be considered in patients with complex CTI anatomy. |
format | Online Article Text |
id | pubmed-3128816 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Indian Heart Rhythm Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-31288162011-07-14 Cavotricuspid Isthmus Anatomy Determines The Success Of Remote Controlled Magnetic Bidirectional Block: A Comparsion Between Magnetic 8-mm Solid Tip And 3.5-mm Magnetic Irrigated Tip Catheter Koektuerk, Buelent Chun, Julian KR Wissner, Erik Schmidt, Boris Ernst, Sabine Ouyang, Feifan Kuck, Karl-Heinz Indian Pacing Electrophysiol J Original Article BACKGROUND: Cavotricuspid isthmus (CTI) anatomy is associated with a great inter-individual variability. The aim of this study was to compare the magnetic 8-mm tip catheter versus the novel 3.5-mm magnetic irrigated tip catheter in achieving bidirectional right atrial isthmus block and to evaluate the impact of the underlying CTI anatomy on success rate. METHODS: A detailed remote controlled 3-dimensional electroanatomic (3D EA) right atrial reconstruction was performed using the magnetic navigation system with special emphasis to the CTI. CTI anatomy was evaluated utilizing the 3D EA map and classified into (A) simple (flat), (B) complex (pouch-like recess or concave shape) or (C) highly complex (pouch-like recess and concave shape). Patients were treated either with the magnetic 8-mm tip catheter (group I) or the open irrigated magnetic 3.5-mm tip catheter (group II). Primary endpoint was defined as acute bidirectional CTI block utilizing exclusively the remote controlled magnetic navigation system. Secondary endpoint was any procedure related complication and procedure time. RESULTS: In group I (n=10, 10 males, mean age: 65 ± 9 years) the primary endpoint was achieved in 80% (8/10 pts) requiring a median (Q1; Q3) RF application time of 37.1 min (22.8; 71.5) and a median (Q1;Q3) cumulative energy (CE) of 70.68 kJ (kilo Joule). (10.76;40.59). In group II (n=13, 10 males, mean age: 60 ± 7 years) the primary endpoint was achieved in 92 % (12/13) with a median (Q1; Q3) RF application time of 21.9 min (13.0; 27.0; p value=0.036) and a CE of 33.54 KJ (26.59; 49.22; p value=0.015). Variable CTI anatomy was identified for group I (type A: n=5 pts, type B: n=5 pts, type C: n=0 pts) and group for II (type A: n=4 pts, type B: n=7 pts, type C: n=2 pts). In group I magnetic ablation failure was associated with type B CTI anatomy (n=2 pts) and in group II with type C CTI (n=1). No procedure related complications were observed. CONCLUSION: Remote controlled catheter ablation of typical atrial flutter using the magnetic navigation system appears to be safe and feasible. CTI anatomy determines remote controlled magnetic ablation success. Use of the magnetic 3.5 mm irrigated tip catheter should be considered in patients with complex CTI anatomy. Indian Heart Rhythm Society 2011-07-03 /pmc/articles/PMC3128816/ /pubmed/21760681 Text en Copyright: © 2011Koektuerk et al. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Koektuerk, Buelent Chun, Julian KR Wissner, Erik Schmidt, Boris Ernst, Sabine Ouyang, Feifan Kuck, Karl-Heinz Cavotricuspid Isthmus Anatomy Determines The Success Of Remote Controlled Magnetic Bidirectional Block: A Comparsion Between Magnetic 8-mm Solid Tip And 3.5-mm Magnetic Irrigated Tip Catheter |
title | Cavotricuspid Isthmus Anatomy Determines The Success Of Remote Controlled Magnetic Bidirectional Block: A Comparsion Between Magnetic 8-mm Solid Tip And 3.5-mm Magnetic Irrigated Tip Catheter |
title_full | Cavotricuspid Isthmus Anatomy Determines The Success Of Remote Controlled Magnetic Bidirectional Block: A Comparsion Between Magnetic 8-mm Solid Tip And 3.5-mm Magnetic Irrigated Tip Catheter |
title_fullStr | Cavotricuspid Isthmus Anatomy Determines The Success Of Remote Controlled Magnetic Bidirectional Block: A Comparsion Between Magnetic 8-mm Solid Tip And 3.5-mm Magnetic Irrigated Tip Catheter |
title_full_unstemmed | Cavotricuspid Isthmus Anatomy Determines The Success Of Remote Controlled Magnetic Bidirectional Block: A Comparsion Between Magnetic 8-mm Solid Tip And 3.5-mm Magnetic Irrigated Tip Catheter |
title_short | Cavotricuspid Isthmus Anatomy Determines The Success Of Remote Controlled Magnetic Bidirectional Block: A Comparsion Between Magnetic 8-mm Solid Tip And 3.5-mm Magnetic Irrigated Tip Catheter |
title_sort | cavotricuspid isthmus anatomy determines the success of remote controlled magnetic bidirectional block: a comparsion between magnetic 8-mm solid tip and 3.5-mm magnetic irrigated tip catheter |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3128816/ https://www.ncbi.nlm.nih.gov/pubmed/21760681 |
work_keys_str_mv | AT koektuerkbuelent cavotricuspidisthmusanatomydeterminesthesuccessofremotecontrolledmagneticbidirectionalblockacomparsionbetweenmagnetic8mmsolidtipand35mmmagneticirrigatedtipcatheter AT chunjuliankr cavotricuspidisthmusanatomydeterminesthesuccessofremotecontrolledmagneticbidirectionalblockacomparsionbetweenmagnetic8mmsolidtipand35mmmagneticirrigatedtipcatheter AT wissnererik cavotricuspidisthmusanatomydeterminesthesuccessofremotecontrolledmagneticbidirectionalblockacomparsionbetweenmagnetic8mmsolidtipand35mmmagneticirrigatedtipcatheter AT schmidtboris cavotricuspidisthmusanatomydeterminesthesuccessofremotecontrolledmagneticbidirectionalblockacomparsionbetweenmagnetic8mmsolidtipand35mmmagneticirrigatedtipcatheter AT ernstsabine cavotricuspidisthmusanatomydeterminesthesuccessofremotecontrolledmagneticbidirectionalblockacomparsionbetweenmagnetic8mmsolidtipand35mmmagneticirrigatedtipcatheter AT ouyangfeifan cavotricuspidisthmusanatomydeterminesthesuccessofremotecontrolledmagneticbidirectionalblockacomparsionbetweenmagnetic8mmsolidtipand35mmmagneticirrigatedtipcatheter AT kuckkarlheinz cavotricuspidisthmusanatomydeterminesthesuccessofremotecontrolledmagneticbidirectionalblockacomparsionbetweenmagnetic8mmsolidtipand35mmmagneticirrigatedtipcatheter |