Cargando…
Multicenter Experience with Nonischemic Multiport Laparoscopic and Laparoendoscopic Single-Site Partial Nephrectomy Utilizing Bipolar Radiofrequency Ablation Coagulator
Objective. To investigate feasibility of multiport and laparoendoscopic single-site (LESS) nonischemic laparoscopic partial nephrectomy (NI-LPN) utilizing bipolar radiofrequency coagulator. Methods. Multicenter retrospective review of 60 patients (46 multiport/14 LESS) undergoing NI-LPN between 4/20...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3130964/ https://www.ncbi.nlm.nih.gov/pubmed/21747654 http://dx.doi.org/10.1155/2011/636537 |
_version_ | 1782207671785488384 |
---|---|
author | Bazzi, Wassim M. Allaf, Mohamad E. Berkowitz, Jared Atalah, Hany N. Parekattil, Sijo Derweesh, Ithaar H. |
author_facet | Bazzi, Wassim M. Allaf, Mohamad E. Berkowitz, Jared Atalah, Hany N. Parekattil, Sijo Derweesh, Ithaar H. |
author_sort | Bazzi, Wassim M. |
collection | PubMed |
description | Objective. To investigate feasibility of multiport and laparoendoscopic single-site (LESS) nonischemic laparoscopic partial nephrectomy (NI-LPN) utilizing bipolar radiofrequency coagulator. Methods. Multicenter retrospective review of 60 patients (46 multiport/14 LESS) undergoing NI-LPN between 4/2006 and 9/2009. Multiport and LESS NI-LPN utilized Habib 4X bipolar radiofrequency coagulator to form a hemostatic zone followed by nonischemic tumor excision and renorrhaphy. Demographics, tumor/perioperative characteristics, and outcomes were analyzed. Results. 59/60 (98.3%) successfully underwent NI-LPN. Mean tumor size was 2.35 cm. Mean operative time was 160.0 minutes. Mean estimated blood loss was 131.4 mL. Preoperative/postoperative creatinine (mg/dL) was 1.02/1.07 (P = .471). All had negative margins. 12 (20%) patients developed complications. 3 (5%) developed urine leaks. No differences between multiport and LESS-PN were noted as regards demographics, tumor size, outcomes, and complications. Conclusion. Initial experience demonstrates that nonischemic multiport and LESS-PN is safe and efficacious, with excellent short-term preservation of renal function. Long-term data are needed to confirm oncological efficacy. |
format | Online Article Text |
id | pubmed-3130964 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-31309642011-07-11 Multicenter Experience with Nonischemic Multiport Laparoscopic and Laparoendoscopic Single-Site Partial Nephrectomy Utilizing Bipolar Radiofrequency Ablation Coagulator Bazzi, Wassim M. Allaf, Mohamad E. Berkowitz, Jared Atalah, Hany N. Parekattil, Sijo Derweesh, Ithaar H. Diagn Ther Endosc Clinical Study Objective. To investigate feasibility of multiport and laparoendoscopic single-site (LESS) nonischemic laparoscopic partial nephrectomy (NI-LPN) utilizing bipolar radiofrequency coagulator. Methods. Multicenter retrospective review of 60 patients (46 multiport/14 LESS) undergoing NI-LPN between 4/2006 and 9/2009. Multiport and LESS NI-LPN utilized Habib 4X bipolar radiofrequency coagulator to form a hemostatic zone followed by nonischemic tumor excision and renorrhaphy. Demographics, tumor/perioperative characteristics, and outcomes were analyzed. Results. 59/60 (98.3%) successfully underwent NI-LPN. Mean tumor size was 2.35 cm. Mean operative time was 160.0 minutes. Mean estimated blood loss was 131.4 mL. Preoperative/postoperative creatinine (mg/dL) was 1.02/1.07 (P = .471). All had negative margins. 12 (20%) patients developed complications. 3 (5%) developed urine leaks. No differences between multiport and LESS-PN were noted as regards demographics, tumor size, outcomes, and complications. Conclusion. Initial experience demonstrates that nonischemic multiport and LESS-PN is safe and efficacious, with excellent short-term preservation of renal function. Long-term data are needed to confirm oncological efficacy. Hindawi Publishing Corporation 2011 2011-06-20 /pmc/articles/PMC3130964/ /pubmed/21747654 http://dx.doi.org/10.1155/2011/636537 Text en Copyright © 2011 Wassim M. Bazzi et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Clinical Study Bazzi, Wassim M. Allaf, Mohamad E. Berkowitz, Jared Atalah, Hany N. Parekattil, Sijo Derweesh, Ithaar H. Multicenter Experience with Nonischemic Multiport Laparoscopic and Laparoendoscopic Single-Site Partial Nephrectomy Utilizing Bipolar Radiofrequency Ablation Coagulator |
title | Multicenter Experience with Nonischemic Multiport Laparoscopic and Laparoendoscopic Single-Site Partial Nephrectomy Utilizing Bipolar Radiofrequency Ablation Coagulator |
title_full | Multicenter Experience with Nonischemic Multiport Laparoscopic and Laparoendoscopic Single-Site Partial Nephrectomy Utilizing Bipolar Radiofrequency Ablation Coagulator |
title_fullStr | Multicenter Experience with Nonischemic Multiport Laparoscopic and Laparoendoscopic Single-Site Partial Nephrectomy Utilizing Bipolar Radiofrequency Ablation Coagulator |
title_full_unstemmed | Multicenter Experience with Nonischemic Multiport Laparoscopic and Laparoendoscopic Single-Site Partial Nephrectomy Utilizing Bipolar Radiofrequency Ablation Coagulator |
title_short | Multicenter Experience with Nonischemic Multiport Laparoscopic and Laparoendoscopic Single-Site Partial Nephrectomy Utilizing Bipolar Radiofrequency Ablation Coagulator |
title_sort | multicenter experience with nonischemic multiport laparoscopic and laparoendoscopic single-site partial nephrectomy utilizing bipolar radiofrequency ablation coagulator |
topic | Clinical Study |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3130964/ https://www.ncbi.nlm.nih.gov/pubmed/21747654 http://dx.doi.org/10.1155/2011/636537 |
work_keys_str_mv | AT bazziwassimm multicenterexperiencewithnonischemicmultiportlaparoscopicandlaparoendoscopicsinglesitepartialnephrectomyutilizingbipolarradiofrequencyablationcoagulator AT allafmohamade multicenterexperiencewithnonischemicmultiportlaparoscopicandlaparoendoscopicsinglesitepartialnephrectomyutilizingbipolarradiofrequencyablationcoagulator AT berkowitzjared multicenterexperiencewithnonischemicmultiportlaparoscopicandlaparoendoscopicsinglesitepartialnephrectomyutilizingbipolarradiofrequencyablationcoagulator AT atalahhanyn multicenterexperiencewithnonischemicmultiportlaparoscopicandlaparoendoscopicsinglesitepartialnephrectomyutilizingbipolarradiofrequencyablationcoagulator AT parekattilsijo multicenterexperiencewithnonischemicmultiportlaparoscopicandlaparoendoscopicsinglesitepartialnephrectomyutilizingbipolarradiofrequencyablationcoagulator AT derweeshithaarh multicenterexperiencewithnonischemicmultiportlaparoscopicandlaparoendoscopicsinglesitepartialnephrectomyutilizingbipolarradiofrequencyablationcoagulator |