Cargando…

Large differences between test strategies for the detection of anti-Borrelia antibodies are revealed by comparing eight ELISAs and five immunoblots

We investigated the influence of assay choice on the results in a two-tier testing algorithm for the detection of anti-Borrelia antibodies. Eighty-nine serum samples from clinically well-defined patients were tested in eight different enzyme-linked immunosorbent assay (ELISA) systems based on whole-...

Descripción completa

Detalles Bibliográficos
Autores principales: Ang, C. W., Notermans, D. W., Hommes, M., Simoons-Smit, A. M., Herremans, T.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer-Verlag 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3132383/
https://www.ncbi.nlm.nih.gov/pubmed/21271270
http://dx.doi.org/10.1007/s10096-011-1157-6
_version_ 1782207815288356864
author Ang, C. W.
Notermans, D. W.
Hommes, M.
Simoons-Smit, A. M.
Herremans, T.
author_facet Ang, C. W.
Notermans, D. W.
Hommes, M.
Simoons-Smit, A. M.
Herremans, T.
author_sort Ang, C. W.
collection PubMed
description We investigated the influence of assay choice on the results in a two-tier testing algorithm for the detection of anti-Borrelia antibodies. Eighty-nine serum samples from clinically well-defined patients were tested in eight different enzyme-linked immunosorbent assay (ELISA) systems based on whole-cell antigens, whole-cell antigens supplemented with VlsE and assays using exclusively recombinant proteins. A subset of samples was tested in five immunoblots: one whole-cell blot, one whole-cell blot supplemented with VlsE and three recombinant blots. The number of IgM- and/or IgG-positive ELISA results in the group of patients suspected of Borrelia infection ranged from 34 to 59%. The percentage of positives in cross-reactivity controls ranged from 0 to 38%. Comparison of immunoblots yielded large differences in inter-test agreement and showed, at best, a moderate agreement between tests. Remarkably, some immunoblots gave positive results in samples that had been tested negative by all eight ELISAs. The percentage of positive blots following a positive ELISA result depended heavily on the choice of ELISA–immunoblot combination. We conclude that the assays used to detect anti-Borrelia antibodies have widely divergent sensitivity and specificity. The choice of ELISA–immunoblot combination severely influences the number of positive results, making the exchange of test results between laboratories with different methodologies hazardous.
format Online
Article
Text
id pubmed-3132383
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Springer-Verlag
record_format MEDLINE/PubMed
spelling pubmed-31323832011-08-24 Large differences between test strategies for the detection of anti-Borrelia antibodies are revealed by comparing eight ELISAs and five immunoblots Ang, C. W. Notermans, D. W. Hommes, M. Simoons-Smit, A. M. Herremans, T. Eur J Clin Microbiol Infect Dis Article We investigated the influence of assay choice on the results in a two-tier testing algorithm for the detection of anti-Borrelia antibodies. Eighty-nine serum samples from clinically well-defined patients were tested in eight different enzyme-linked immunosorbent assay (ELISA) systems based on whole-cell antigens, whole-cell antigens supplemented with VlsE and assays using exclusively recombinant proteins. A subset of samples was tested in five immunoblots: one whole-cell blot, one whole-cell blot supplemented with VlsE and three recombinant blots. The number of IgM- and/or IgG-positive ELISA results in the group of patients suspected of Borrelia infection ranged from 34 to 59%. The percentage of positives in cross-reactivity controls ranged from 0 to 38%. Comparison of immunoblots yielded large differences in inter-test agreement and showed, at best, a moderate agreement between tests. Remarkably, some immunoblots gave positive results in samples that had been tested negative by all eight ELISAs. The percentage of positive blots following a positive ELISA result depended heavily on the choice of ELISA–immunoblot combination. We conclude that the assays used to detect anti-Borrelia antibodies have widely divergent sensitivity and specificity. The choice of ELISA–immunoblot combination severely influences the number of positive results, making the exchange of test results between laboratories with different methodologies hazardous. Springer-Verlag 2011-01-27 2011 /pmc/articles/PMC3132383/ /pubmed/21271270 http://dx.doi.org/10.1007/s10096-011-1157-6 Text en © The Author(s) 2011 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.
spellingShingle Article
Ang, C. W.
Notermans, D. W.
Hommes, M.
Simoons-Smit, A. M.
Herremans, T.
Large differences between test strategies for the detection of anti-Borrelia antibodies are revealed by comparing eight ELISAs and five immunoblots
title Large differences between test strategies for the detection of anti-Borrelia antibodies are revealed by comparing eight ELISAs and five immunoblots
title_full Large differences between test strategies for the detection of anti-Borrelia antibodies are revealed by comparing eight ELISAs and five immunoblots
title_fullStr Large differences between test strategies for the detection of anti-Borrelia antibodies are revealed by comparing eight ELISAs and five immunoblots
title_full_unstemmed Large differences between test strategies for the detection of anti-Borrelia antibodies are revealed by comparing eight ELISAs and five immunoblots
title_short Large differences between test strategies for the detection of anti-Borrelia antibodies are revealed by comparing eight ELISAs and five immunoblots
title_sort large differences between test strategies for the detection of anti-borrelia antibodies are revealed by comparing eight elisas and five immunoblots
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3132383/
https://www.ncbi.nlm.nih.gov/pubmed/21271270
http://dx.doi.org/10.1007/s10096-011-1157-6
work_keys_str_mv AT angcw largedifferencesbetweenteststrategiesforthedetectionofantiborreliaantibodiesarerevealedbycomparingeightelisasandfiveimmunoblots
AT notermansdw largedifferencesbetweenteststrategiesforthedetectionofantiborreliaantibodiesarerevealedbycomparingeightelisasandfiveimmunoblots
AT hommesm largedifferencesbetweenteststrategiesforthedetectionofantiborreliaantibodiesarerevealedbycomparingeightelisasandfiveimmunoblots
AT simoonssmitam largedifferencesbetweenteststrategiesforthedetectionofantiborreliaantibodiesarerevealedbycomparingeightelisasandfiveimmunoblots
AT herremanst largedifferencesbetweenteststrategiesforthedetectionofantiborreliaantibodiesarerevealedbycomparingeightelisasandfiveimmunoblots