Cargando…
Quantification of Lansoprazole in Oral Suspension by Ultra-High-Performance Liquid Chromatography Hybrid Ion-Trap Time-of-Flight Mass Spectrometry
An LC-MS/MS method was developed and validated to be used as a stability indicating assay for the study of a 3 mg/mL lansoprazole oral suspension. The method utilizes a UPLC (ultra-performance liquid chromatography) column and unique mass spectrometric detection (ion-trap time-of-flight (IT-TOF)) to...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3132987/ https://www.ncbi.nlm.nih.gov/pubmed/21754935 http://dx.doi.org/10.1155/2011/832414 |
Sumario: | An LC-MS/MS method was developed and validated to be used as a stability indicating assay for the study of a 3 mg/mL lansoprazole oral suspension. The method utilizes a UPLC (ultra-performance liquid chromatography) column and unique mass spectrometric detection (ion-trap time-of-flight (IT-TOF)) to achieve a sensitive (LOD 2 ng/mL), accurate, and reproducible quantification of lansoprazole. This method reports an intraday and interday coefficient of variation of 2.98 ± 2.17% (n = 5 for each concentration for each day) and 3.07 ± 0.89% (n = 20 for each concentration), respectively. Calibration curves (5–25 μg/mL) were found to be linear with an R(2) value ranging from 0.9972 to 0.9991 on 4 different days. Accuracy of the assay, expressed as % error, ranged from 0.30 to 5.22%. This method is useful for monitoring the stability of lansoprazole in oral suspension. |
---|