Cargando…

Numerical optimization of spherical variable-line-spacing grating X-ray spectrometers

Operation of an X-ray spectrometer based on a spherical variable-line-spacing (VLS) grating is analyzed using dedicated ray-tracing software allowing fast optimization of the grating parameters and spectrometer geometry. The analysis is illustrated with optical design of a model spectrometer to deli...

Descripción completa

Detalles Bibliográficos
Autores principales: Strocov, V. N., Schmitt, T., Flechsig, U., Patthey, L., Chiuzbăian, G. S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Union of Crystallography 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3133478/
https://www.ncbi.nlm.nih.gov/pubmed/21335898
http://dx.doi.org/10.1107/S0909049510054452
_version_ 1782207899651538944
author Strocov, V. N.
Schmitt, T.
Flechsig, U.
Patthey, L.
Chiuzbăian, G. S.
author_facet Strocov, V. N.
Schmitt, T.
Flechsig, U.
Patthey, L.
Chiuzbăian, G. S.
author_sort Strocov, V. N.
collection PubMed
description Operation of an X-ray spectrometer based on a spherical variable-line-spacing (VLS) grating is analyzed using dedicated ray-tracing software allowing fast optimization of the grating parameters and spectrometer geometry. The analysis is illustrated with optical design of a model spectrometer to deliver a resolving power above 20400 at a photon energy of 930 eV (Cu L-edge). With this energy taken as reference, the VLS coefficients are optimized to cancel the lineshape asymmetry (mostly from the coma aberrations) as well as minimize the symmetric aberration broadening at large grating illuminations, dramatically increasing the aberration-limited vertical acceptance of the spectrometer. For any energy away from the reference, corrections to the entrance arm and light incidence angle on the grating are evaluated to maintain the exactly symmetric lineshape. Furthermore, operational modes when these corrections are coordinated are evaluated to maintain either energy-independent focal curve inclination or maximal aberration-limited spectrometer acceptance. The results are supported by analytical evaluation of the coma term of the optical path function. This analysis thus gives a recipe for designing a high-resolution spherical VLS grating spectrometer operating with negligible aberrations at large acceptance and over an extended energy range.
format Online
Article
Text
id pubmed-3133478
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher International Union of Crystallography
record_format MEDLINE/PubMed
spelling pubmed-31334782011-07-20 Numerical optimization of spherical variable-line-spacing grating X-ray spectrometers Strocov, V. N. Schmitt, T. Flechsig, U. Patthey, L. Chiuzbăian, G. S. J Synchrotron Radiat Research Papers Operation of an X-ray spectrometer based on a spherical variable-line-spacing (VLS) grating is analyzed using dedicated ray-tracing software allowing fast optimization of the grating parameters and spectrometer geometry. The analysis is illustrated with optical design of a model spectrometer to deliver a resolving power above 20400 at a photon energy of 930 eV (Cu L-edge). With this energy taken as reference, the VLS coefficients are optimized to cancel the lineshape asymmetry (mostly from the coma aberrations) as well as minimize the symmetric aberration broadening at large grating illuminations, dramatically increasing the aberration-limited vertical acceptance of the spectrometer. For any energy away from the reference, corrections to the entrance arm and light incidence angle on the grating are evaluated to maintain the exactly symmetric lineshape. Furthermore, operational modes when these corrections are coordinated are evaluated to maintain either energy-independent focal curve inclination or maximal aberration-limited spectrometer acceptance. The results are supported by analytical evaluation of the coma term of the optical path function. This analysis thus gives a recipe for designing a high-resolution spherical VLS grating spectrometer operating with negligible aberrations at large acceptance and over an extended energy range. International Union of Crystallography 2011-03-01 2011-01-29 /pmc/articles/PMC3133478/ /pubmed/21335898 http://dx.doi.org/10.1107/S0909049510054452 Text en © V. N. Strocov et al. 2011 http://creativecommons.org/licenses/by/2.0/uk/ This is an open-access article distributed under the terms of the Creative Commons Attribution Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.
spellingShingle Research Papers
Strocov, V. N.
Schmitt, T.
Flechsig, U.
Patthey, L.
Chiuzbăian, G. S.
Numerical optimization of spherical variable-line-spacing grating X-ray spectrometers
title Numerical optimization of spherical variable-line-spacing grating X-ray spectrometers
title_full Numerical optimization of spherical variable-line-spacing grating X-ray spectrometers
title_fullStr Numerical optimization of spherical variable-line-spacing grating X-ray spectrometers
title_full_unstemmed Numerical optimization of spherical variable-line-spacing grating X-ray spectrometers
title_short Numerical optimization of spherical variable-line-spacing grating X-ray spectrometers
title_sort numerical optimization of spherical variable-line-spacing grating x-ray spectrometers
topic Research Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3133478/
https://www.ncbi.nlm.nih.gov/pubmed/21335898
http://dx.doi.org/10.1107/S0909049510054452
work_keys_str_mv AT strocovvn numericaloptimizationofsphericalvariablelinespacinggratingxrayspectrometers
AT schmittt numericaloptimizationofsphericalvariablelinespacinggratingxrayspectrometers
AT flechsigu numericaloptimizationofsphericalvariablelinespacinggratingxrayspectrometers
AT pattheyl numericaloptimizationofsphericalvariablelinespacinggratingxrayspectrometers
AT chiuzbaiangs numericaloptimizationofsphericalvariablelinespacinggratingxrayspectrometers