Cargando…

Automatic loop centring with a high-precision goniometer head at the SLS macromolecular crystallography beamlines

Automatic loop centring has been developed as part of the automation process in crystallographic data collection at the Swiss Light Source. The procedure described here consists of an optional set-up part, in which the background images are taken, and the actual centring part. The algorithm uses bou...

Descripción completa

Detalles Bibliográficos
Autores principales: Pauluhn, Anuschka, Pradervand, Claude, Rossetti, Daniel, Salathe, Marco, Schulze-Briese, Clemens
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Union of Crystallography 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3133520/
https://www.ncbi.nlm.nih.gov/pubmed/21685676
http://dx.doi.org/10.1107/S0909049511011848
_version_ 1782207906469380096
author Pauluhn, Anuschka
Pradervand, Claude
Rossetti, Daniel
Salathe, Marco
Schulze-Briese, Clemens
author_facet Pauluhn, Anuschka
Pradervand, Claude
Rossetti, Daniel
Salathe, Marco
Schulze-Briese, Clemens
author_sort Pauluhn, Anuschka
collection PubMed
description Automatic loop centring has been developed as part of the automation process in crystallographic data collection at the Swiss Light Source. The procedure described here consists of an optional set-up part, in which the background images are taken, and the actual centring part. The algorithm uses boundary and centre-of-mass detection at two different microscope image magnifications. Micromounts can be handled as well. Centring of the loops can be achieved in 15–26 s, depending on their initial position, and as fast as manual centring. The alignment of the sample is carried out by means of a new flexural-hinge-based compact goniometer head. The device features an electromagnet for robotic wet mounting of samples. The circle of confusion was measured to be smaller than 1 µm (r.m.s.); its bidirectional backlash is below 2 µm.
format Online
Article
Text
id pubmed-3133520
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher International Union of Crystallography
record_format MEDLINE/PubMed
spelling pubmed-31335202011-07-13 Automatic loop centring with a high-precision goniometer head at the SLS macromolecular crystallography beamlines Pauluhn, Anuschka Pradervand, Claude Rossetti, Daniel Salathe, Marco Schulze-Briese, Clemens J Synchrotron Radiat Research Papers Automatic loop centring has been developed as part of the automation process in crystallographic data collection at the Swiss Light Source. The procedure described here consists of an optional set-up part, in which the background images are taken, and the actual centring part. The algorithm uses boundary and centre-of-mass detection at two different microscope image magnifications. Micromounts can be handled as well. Centring of the loops can be achieved in 15–26 s, depending on their initial position, and as fast as manual centring. The alignment of the sample is carried out by means of a new flexural-hinge-based compact goniometer head. The device features an electromagnet for robotic wet mounting of samples. The circle of confusion was measured to be smaller than 1 µm (r.m.s.); its bidirectional backlash is below 2 µm. International Union of Crystallography 2011-07-01 2011-05-14 /pmc/articles/PMC3133520/ /pubmed/21685676 http://dx.doi.org/10.1107/S0909049511011848 Text en © Anuschka Pauluhn et al. 2011 http://creativecommons.org/licenses/by/2.0/uk/ This is an open-access article distributed under the terms of the Creative Commons Attribution Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.
spellingShingle Research Papers
Pauluhn, Anuschka
Pradervand, Claude
Rossetti, Daniel
Salathe, Marco
Schulze-Briese, Clemens
Automatic loop centring with a high-precision goniometer head at the SLS macromolecular crystallography beamlines
title Automatic loop centring with a high-precision goniometer head at the SLS macromolecular crystallography beamlines
title_full Automatic loop centring with a high-precision goniometer head at the SLS macromolecular crystallography beamlines
title_fullStr Automatic loop centring with a high-precision goniometer head at the SLS macromolecular crystallography beamlines
title_full_unstemmed Automatic loop centring with a high-precision goniometer head at the SLS macromolecular crystallography beamlines
title_short Automatic loop centring with a high-precision goniometer head at the SLS macromolecular crystallography beamlines
title_sort automatic loop centring with a high-precision goniometer head at the sls macromolecular crystallography beamlines
topic Research Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3133520/
https://www.ncbi.nlm.nih.gov/pubmed/21685676
http://dx.doi.org/10.1107/S0909049511011848
work_keys_str_mv AT pauluhnanuschka automaticloopcentringwithahighprecisiongoniometerheadattheslsmacromolecularcrystallographybeamlines
AT pradervandclaude automaticloopcentringwithahighprecisiongoniometerheadattheslsmacromolecularcrystallographybeamlines
AT rossettidaniel automaticloopcentringwithahighprecisiongoniometerheadattheslsmacromolecularcrystallographybeamlines
AT salathemarco automaticloopcentringwithahighprecisiongoniometerheadattheslsmacromolecularcrystallographybeamlines
AT schulzebrieseclemens automaticloopcentringwithahighprecisiongoniometerheadattheslsmacromolecularcrystallographybeamlines