Cargando…
Automatic loop centring with a high-precision goniometer head at the SLS macromolecular crystallography beamlines
Automatic loop centring has been developed as part of the automation process in crystallographic data collection at the Swiss Light Source. The procedure described here consists of an optional set-up part, in which the background images are taken, and the actual centring part. The algorithm uses bou...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Union of Crystallography
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3133520/ https://www.ncbi.nlm.nih.gov/pubmed/21685676 http://dx.doi.org/10.1107/S0909049511011848 |
_version_ | 1782207906469380096 |
---|---|
author | Pauluhn, Anuschka Pradervand, Claude Rossetti, Daniel Salathe, Marco Schulze-Briese, Clemens |
author_facet | Pauluhn, Anuschka Pradervand, Claude Rossetti, Daniel Salathe, Marco Schulze-Briese, Clemens |
author_sort | Pauluhn, Anuschka |
collection | PubMed |
description | Automatic loop centring has been developed as part of the automation process in crystallographic data collection at the Swiss Light Source. The procedure described here consists of an optional set-up part, in which the background images are taken, and the actual centring part. The algorithm uses boundary and centre-of-mass detection at two different microscope image magnifications. Micromounts can be handled as well. Centring of the loops can be achieved in 15–26 s, depending on their initial position, and as fast as manual centring. The alignment of the sample is carried out by means of a new flexural-hinge-based compact goniometer head. The device features an electromagnet for robotic wet mounting of samples. The circle of confusion was measured to be smaller than 1 µm (r.m.s.); its bidirectional backlash is below 2 µm. |
format | Online Article Text |
id | pubmed-3133520 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | International Union of Crystallography |
record_format | MEDLINE/PubMed |
spelling | pubmed-31335202011-07-13 Automatic loop centring with a high-precision goniometer head at the SLS macromolecular crystallography beamlines Pauluhn, Anuschka Pradervand, Claude Rossetti, Daniel Salathe, Marco Schulze-Briese, Clemens J Synchrotron Radiat Research Papers Automatic loop centring has been developed as part of the automation process in crystallographic data collection at the Swiss Light Source. The procedure described here consists of an optional set-up part, in which the background images are taken, and the actual centring part. The algorithm uses boundary and centre-of-mass detection at two different microscope image magnifications. Micromounts can be handled as well. Centring of the loops can be achieved in 15–26 s, depending on their initial position, and as fast as manual centring. The alignment of the sample is carried out by means of a new flexural-hinge-based compact goniometer head. The device features an electromagnet for robotic wet mounting of samples. The circle of confusion was measured to be smaller than 1 µm (r.m.s.); its bidirectional backlash is below 2 µm. International Union of Crystallography 2011-07-01 2011-05-14 /pmc/articles/PMC3133520/ /pubmed/21685676 http://dx.doi.org/10.1107/S0909049511011848 Text en © Anuschka Pauluhn et al. 2011 http://creativecommons.org/licenses/by/2.0/uk/ This is an open-access article distributed under the terms of the Creative Commons Attribution Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited. |
spellingShingle | Research Papers Pauluhn, Anuschka Pradervand, Claude Rossetti, Daniel Salathe, Marco Schulze-Briese, Clemens Automatic loop centring with a high-precision goniometer head at the SLS macromolecular crystallography beamlines |
title | Automatic loop centring with a high-precision goniometer head at the SLS macromolecular crystallography beamlines |
title_full | Automatic loop centring with a high-precision goniometer head at the SLS macromolecular crystallography beamlines |
title_fullStr | Automatic loop centring with a high-precision goniometer head at the SLS macromolecular crystallography beamlines |
title_full_unstemmed | Automatic loop centring with a high-precision goniometer head at the SLS macromolecular crystallography beamlines |
title_short | Automatic loop centring with a high-precision goniometer head at the SLS macromolecular crystallography beamlines |
title_sort | automatic loop centring with a high-precision goniometer head at the sls macromolecular crystallography beamlines |
topic | Research Papers |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3133520/ https://www.ncbi.nlm.nih.gov/pubmed/21685676 http://dx.doi.org/10.1107/S0909049511011848 |
work_keys_str_mv | AT pauluhnanuschka automaticloopcentringwithahighprecisiongoniometerheadattheslsmacromolecularcrystallographybeamlines AT pradervandclaude automaticloopcentringwithahighprecisiongoniometerheadattheslsmacromolecularcrystallographybeamlines AT rossettidaniel automaticloopcentringwithahighprecisiongoniometerheadattheslsmacromolecularcrystallographybeamlines AT salathemarco automaticloopcentringwithahighprecisiongoniometerheadattheslsmacromolecularcrystallographybeamlines AT schulzebrieseclemens automaticloopcentringwithahighprecisiongoniometerheadattheslsmacromolecularcrystallographybeamlines |