Effect of 50% and maximal inspired oxygen concentrations on respiratory variables in isoflurane-anesthetized horses

BACKGROUND: The purpose of this study was to compare the effects of 0.5 fraction of inspired oxygen (FiO(2)) and >0.95 FiO(2 )on pulmonary gas exchange, shunt fraction and oxygen delivery (DO(2)) in dorsally recumbent horses during inhalant anesthesia. The use of 0.5 FiO(2 )has the potential to r...

Descripción completa

Detalles Bibliográficos
Autores principales: Hubbell, John AE, Aarnes, Turi K, Bednarski, Richard M, Lerche, Phillip, Muir, William W
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3133541/
https://www.ncbi.nlm.nih.gov/pubmed/21639886
http://dx.doi.org/10.1186/1746-6148-7-23
_version_ 1782207910568263680
author Hubbell, John AE
Aarnes, Turi K
Bednarski, Richard M
Lerche, Phillip
Muir, William W
author_facet Hubbell, John AE
Aarnes, Turi K
Bednarski, Richard M
Lerche, Phillip
Muir, William W
author_sort Hubbell, John AE
collection PubMed
description BACKGROUND: The purpose of this study was to compare the effects of 0.5 fraction of inspired oxygen (FiO(2)) and >0.95 FiO(2 )on pulmonary gas exchange, shunt fraction and oxygen delivery (DO(2)) in dorsally recumbent horses during inhalant anesthesia. The use of 0.5 FiO(2 )has the potential to reduce absorption atelectasis (compared to maximal FiO(2)) and augment alveolar oxygen (O(2)) tensions (compared to ambient air) thereby improving gas exchange and DO(2). Our hypothesis was that 0.5 FiO(2 )would reduce ventilation-perfusion mismatching and increase the fraction of pulmonary blood flow that is oxygenated, thus improving arterial oxygen content and DO(2). RESULTS: Arterial partial pressures of O(2 )were significantly higher than preanesthetic levels at all times during anesthesia in the >0.95 FiO(2 )group. Arterial partial pressures of O(2 )did not change from preanesthetic levels in the 0.5 FiO(2 )group but were significantly lower than in the >0.95 FiO(2 )group from 15 to 90 min of anesthesia. Alveolar to arterial O(2 )tension difference was increased significantly in both groups during anesthesia compared to preanesthetic values. The alveolar to arterial O(2 )tension difference was significantly higher at all times in the >0.95 FiO(2 )group compared to the 0.5 FiO(2 )group. Oxygen delivery did not change from preanesthetic values in either group during anesthesia but was significantly lower than preanesthetic values 10 min after anesthesia in the 0.5 FiO(2 )group. Shunt fraction increased in both groups during anesthesia attaining statistical significance at varying times. Shunt fraction was significantly increased in both groups 10 min after anesthesia but was not different between groups. Alveolar dead space ventilation increased after 3 hr of anesthesia in both groups. CONCLUSIONS: Reducing FiO(2 )did not change alveolar dead space ventilation or shunt fraction in dorsally recumbent, mechanically ventilated horses during 3 hr of isoflurane anesthesia. Reducing FiO(2 )in dorsally recumbent isoflurane anesthetized horses does not improve oxygenation or oxygen delivery.
format Online
Article
Text
id pubmed-3133541
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-31335412011-07-12 Effect of 50% and maximal inspired oxygen concentrations on respiratory variables in isoflurane-anesthetized horses Hubbell, John AE Aarnes, Turi K Bednarski, Richard M Lerche, Phillip Muir, William W BMC Vet Res Research Article BACKGROUND: The purpose of this study was to compare the effects of 0.5 fraction of inspired oxygen (FiO(2)) and >0.95 FiO(2 )on pulmonary gas exchange, shunt fraction and oxygen delivery (DO(2)) in dorsally recumbent horses during inhalant anesthesia. The use of 0.5 FiO(2 )has the potential to reduce absorption atelectasis (compared to maximal FiO(2)) and augment alveolar oxygen (O(2)) tensions (compared to ambient air) thereby improving gas exchange and DO(2). Our hypothesis was that 0.5 FiO(2 )would reduce ventilation-perfusion mismatching and increase the fraction of pulmonary blood flow that is oxygenated, thus improving arterial oxygen content and DO(2). RESULTS: Arterial partial pressures of O(2 )were significantly higher than preanesthetic levels at all times during anesthesia in the >0.95 FiO(2 )group. Arterial partial pressures of O(2 )did not change from preanesthetic levels in the 0.5 FiO(2 )group but were significantly lower than in the >0.95 FiO(2 )group from 15 to 90 min of anesthesia. Alveolar to arterial O(2 )tension difference was increased significantly in both groups during anesthesia compared to preanesthetic values. The alveolar to arterial O(2 )tension difference was significantly higher at all times in the >0.95 FiO(2 )group compared to the 0.5 FiO(2 )group. Oxygen delivery did not change from preanesthetic values in either group during anesthesia but was significantly lower than preanesthetic values 10 min after anesthesia in the 0.5 FiO(2 )group. Shunt fraction increased in both groups during anesthesia attaining statistical significance at varying times. Shunt fraction was significantly increased in both groups 10 min after anesthesia but was not different between groups. Alveolar dead space ventilation increased after 3 hr of anesthesia in both groups. CONCLUSIONS: Reducing FiO(2 )did not change alveolar dead space ventilation or shunt fraction in dorsally recumbent, mechanically ventilated horses during 3 hr of isoflurane anesthesia. Reducing FiO(2 )in dorsally recumbent isoflurane anesthetized horses does not improve oxygenation or oxygen delivery. BioMed Central 2011-06-03 /pmc/articles/PMC3133541/ /pubmed/21639886 http://dx.doi.org/10.1186/1746-6148-7-23 Text en Copyright ©2011 Hubbell et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Hubbell, John AE
Aarnes, Turi K
Bednarski, Richard M
Lerche, Phillip
Muir, William W
Effect of 50% and maximal inspired oxygen concentrations on respiratory variables in isoflurane-anesthetized horses
title Effect of 50% and maximal inspired oxygen concentrations on respiratory variables in isoflurane-anesthetized horses
title_full Effect of 50% and maximal inspired oxygen concentrations on respiratory variables in isoflurane-anesthetized horses
title_fullStr Effect of 50% and maximal inspired oxygen concentrations on respiratory variables in isoflurane-anesthetized horses
title_full_unstemmed Effect of 50% and maximal inspired oxygen concentrations on respiratory variables in isoflurane-anesthetized horses
title_short Effect of 50% and maximal inspired oxygen concentrations on respiratory variables in isoflurane-anesthetized horses
title_sort effect of 50% and maximal inspired oxygen concentrations on respiratory variables in isoflurane-anesthetized horses
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3133541/
https://www.ncbi.nlm.nih.gov/pubmed/21639886
http://dx.doi.org/10.1186/1746-6148-7-23
work_keys_str_mv AT hubbelljohnae effectof50andmaximalinspiredoxygenconcentrationsonrespiratoryvariablesinisofluraneanesthetizedhorses
AT aarnesturik effectof50andmaximalinspiredoxygenconcentrationsonrespiratoryvariablesinisofluraneanesthetizedhorses
AT bednarskirichardm effectof50andmaximalinspiredoxygenconcentrationsonrespiratoryvariablesinisofluraneanesthetizedhorses
AT lerchephillip effectof50andmaximalinspiredoxygenconcentrationsonrespiratoryvariablesinisofluraneanesthetizedhorses
AT muirwilliamw effectof50andmaximalinspiredoxygenconcentrationsonrespiratoryvariablesinisofluraneanesthetizedhorses