Cargando…

Closed retrograde retrieval of the distal broken segment of femoral cannulated intramedullary nail using a ball-tipped guide wire

BACKGROUND: Extracting broken segments of intramedullay nails from long bones can be an operative challenge, particularly from the distal end. We report a case series where a simple and reproducible technique of extracting broken femoral cannulated nails using a ball-tipped guide wire is described....

Descripción completa

Detalles Bibliográficos
Autores principales: Metikala, Sreenivasulu, Mohammed, Riazuddin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications Pvt Ltd 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3134021/
https://www.ncbi.nlm.nih.gov/pubmed/21772629
http://dx.doi.org/10.4103/0019-5413.82342
_version_ 1782207946057318400
author Metikala, Sreenivasulu
Mohammed, Riazuddin
author_facet Metikala, Sreenivasulu
Mohammed, Riazuddin
author_sort Metikala, Sreenivasulu
collection PubMed
description BACKGROUND: Extracting broken segments of intramedullay nails from long bones can be an operative challenge, particularly from the distal end. We report a case series where a simple and reproducible technique of extracting broken femoral cannulated nails using a ball-tipped guide wire is described. This closed technique involves no additional equipment or instruments. MATERIALS AND METHODS: Eight patients who underwent the described method were included in the study. The technique involves using a standard plain guide wire passed through the cannulated distal broken nail segment after extraction of the proximal nail fragment. The plain guide wire is then advanced distally into the knee joint carefully under fluoroscopy imaging. Over this wire, a 5-millimeter (mm) cannulated large drill bit is used to create a track up to the distal broken nail segment. Through the small knee wound, a ball-tipped guide wire is passed, smooth end first, till the ball engages the end of the nail. The guide wire is then extracted along with the broken nail through the proximal wound. RESULTS: The method was successfully used in all eight patients for removal of broken cannulated intramedullary nail from the femoral canal without any complications. All patients underwent exchange nailing with successful bone union in six months. None of the patients had any problems at the knee joint at the final follow-up. CONCLUSION: We report a technique for successful extraction of the distal fragment of broken femoral intramedullary nails without additional surgical approaches.
format Online
Article
Text
id pubmed-3134021
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Medknow Publications Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-31340212011-07-19 Closed retrograde retrieval of the distal broken segment of femoral cannulated intramedullary nail using a ball-tipped guide wire Metikala, Sreenivasulu Mohammed, Riazuddin Indian J Orthop Original Article BACKGROUND: Extracting broken segments of intramedullay nails from long bones can be an operative challenge, particularly from the distal end. We report a case series where a simple and reproducible technique of extracting broken femoral cannulated nails using a ball-tipped guide wire is described. This closed technique involves no additional equipment or instruments. MATERIALS AND METHODS: Eight patients who underwent the described method were included in the study. The technique involves using a standard plain guide wire passed through the cannulated distal broken nail segment after extraction of the proximal nail fragment. The plain guide wire is then advanced distally into the knee joint carefully under fluoroscopy imaging. Over this wire, a 5-millimeter (mm) cannulated large drill bit is used to create a track up to the distal broken nail segment. Through the small knee wound, a ball-tipped guide wire is passed, smooth end first, till the ball engages the end of the nail. The guide wire is then extracted along with the broken nail through the proximal wound. RESULTS: The method was successfully used in all eight patients for removal of broken cannulated intramedullary nail from the femoral canal without any complications. All patients underwent exchange nailing with successful bone union in six months. None of the patients had any problems at the knee joint at the final follow-up. CONCLUSION: We report a technique for successful extraction of the distal fragment of broken femoral intramedullary nails without additional surgical approaches. Medknow Publications Pvt Ltd 2011 /pmc/articles/PMC3134021/ /pubmed/21772629 http://dx.doi.org/10.4103/0019-5413.82342 Text en © Indian Journal of Orthopaedics http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Metikala, Sreenivasulu
Mohammed, Riazuddin
Closed retrograde retrieval of the distal broken segment of femoral cannulated intramedullary nail using a ball-tipped guide wire
title Closed retrograde retrieval of the distal broken segment of femoral cannulated intramedullary nail using a ball-tipped guide wire
title_full Closed retrograde retrieval of the distal broken segment of femoral cannulated intramedullary nail using a ball-tipped guide wire
title_fullStr Closed retrograde retrieval of the distal broken segment of femoral cannulated intramedullary nail using a ball-tipped guide wire
title_full_unstemmed Closed retrograde retrieval of the distal broken segment of femoral cannulated intramedullary nail using a ball-tipped guide wire
title_short Closed retrograde retrieval of the distal broken segment of femoral cannulated intramedullary nail using a ball-tipped guide wire
title_sort closed retrograde retrieval of the distal broken segment of femoral cannulated intramedullary nail using a ball-tipped guide wire
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3134021/
https://www.ncbi.nlm.nih.gov/pubmed/21772629
http://dx.doi.org/10.4103/0019-5413.82342
work_keys_str_mv AT metikalasreenivasulu closedretrograderetrievalofthedistalbrokensegmentoffemoralcannulatedintramedullarynailusingaballtippedguidewire
AT mohammedriazuddin closedretrograderetrievalofthedistalbrokensegmentoffemoralcannulatedintramedullarynailusingaballtippedguidewire