Cargando…

Toxic Anterior Segment Syndrome after Foldable Artiflex Iris-Fixated Phakic Intraocular Lens Implantation

Toxic anterior segment syndrome (TASS) developed in four cases after uneventful implantation of a foldable iris-fixated phakic intraocular lens (pIOL). Two cases occurred sequentially in one patient. The TASS subsided without complications in all cases after intensive topical steroid treatment. A mu...

Descripción completa

Detalles Bibliográficos
Autor principal: van Philips, Lucien A. M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3136180/
https://www.ncbi.nlm.nih.gov/pubmed/21772989
http://dx.doi.org/10.1155/2011/982410
_version_ 1782208182467166208
author van Philips, Lucien A. M.
author_facet van Philips, Lucien A. M.
author_sort van Philips, Lucien A. M.
collection PubMed
description Toxic anterior segment syndrome (TASS) developed in four cases after uneventful implantation of a foldable iris-fixated phakic intraocular lens (pIOL). Two cases occurred sequentially in one patient. The TASS subsided without complications in all cases after intensive topical steroid treatment. A multitude of possible causes is considered for the occurrence of these TASS cases. From the sterilization and cleaning of surgical instruments to the possibility of endotoxines in ophthalmic viscosurgical devices (OVD). These rare cases should alert the surgeon to the possibility of TASS after pIOL implantation.
format Online
Article
Text
id pubmed-3136180
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-31361802011-07-19 Toxic Anterior Segment Syndrome after Foldable Artiflex Iris-Fixated Phakic Intraocular Lens Implantation van Philips, Lucien A. M. J Ophthalmol Case Report Toxic anterior segment syndrome (TASS) developed in four cases after uneventful implantation of a foldable iris-fixated phakic intraocular lens (pIOL). Two cases occurred sequentially in one patient. The TASS subsided without complications in all cases after intensive topical steroid treatment. A multitude of possible causes is considered for the occurrence of these TASS cases. From the sterilization and cleaning of surgical instruments to the possibility of endotoxines in ophthalmic viscosurgical devices (OVD). These rare cases should alert the surgeon to the possibility of TASS after pIOL implantation. Hindawi Publishing Corporation 2011 2011-06-05 /pmc/articles/PMC3136180/ /pubmed/21772989 http://dx.doi.org/10.1155/2011/982410 Text en Copyright © 2011 Lucien A. M. van Philips. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
van Philips, Lucien A. M.
Toxic Anterior Segment Syndrome after Foldable Artiflex Iris-Fixated Phakic Intraocular Lens Implantation
title Toxic Anterior Segment Syndrome after Foldable Artiflex Iris-Fixated Phakic Intraocular Lens Implantation
title_full Toxic Anterior Segment Syndrome after Foldable Artiflex Iris-Fixated Phakic Intraocular Lens Implantation
title_fullStr Toxic Anterior Segment Syndrome after Foldable Artiflex Iris-Fixated Phakic Intraocular Lens Implantation
title_full_unstemmed Toxic Anterior Segment Syndrome after Foldable Artiflex Iris-Fixated Phakic Intraocular Lens Implantation
title_short Toxic Anterior Segment Syndrome after Foldable Artiflex Iris-Fixated Phakic Intraocular Lens Implantation
title_sort toxic anterior segment syndrome after foldable artiflex iris-fixated phakic intraocular lens implantation
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3136180/
https://www.ncbi.nlm.nih.gov/pubmed/21772989
http://dx.doi.org/10.1155/2011/982410
work_keys_str_mv AT vanphilipslucienam toxicanteriorsegmentsyndromeafterfoldableartiflexirisfixatedphakicintraocularlensimplantation