Cargando…
The relationship between initial implant stability quotient values and bone-to-implant contact ratio in the rabbit tibia
PURPOSE: Implant stability quotient (ISQ) values have been supposed to predict implant stability. However, the relationship between ISQ values and bone-to-implant contact ratio (BIC%) which is one of the predictors of implant stability is still unclear. The aim of the present study was to evaluate i...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Academy of Prosthodontics
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3141122/ https://www.ncbi.nlm.nih.gov/pubmed/21814615 http://dx.doi.org/10.4047/jap.2011.3.2.76 |
_version_ | 1782208629801222144 |
---|---|
author | Park, In-Phill Kim, Seong-Kyun Lee, Shin-Jae Lee, Joo-Hee |
author_facet | Park, In-Phill Kim, Seong-Kyun Lee, Shin-Jae Lee, Joo-Hee |
author_sort | Park, In-Phill |
collection | PubMed |
description | PURPOSE: Implant stability quotient (ISQ) values have been supposed to predict implant stability. However, the relationship between ISQ values and bone-to-implant contact ratio (BIC%) which is one of the predictors of implant stability is still unclear. The aim of the present study was to evaluate initial ISQ values in relation to BIC% using rabbit model. MATERIALS AND METHODS: Four New Zealand white rabbits received a total of 16 implants in their tibia. Immediately after implant placement ISQ values were assessed. The measurements were repeated at the time of sacrifice of the rabbits after 4 weeks. Peri-implant bone regeneration was assessed histomorphometrically by measuring BIC% and bone volume to total volume values (bone volume %). The relationships between ISQ values and the histomorphometric output were assessed, and then, the osseointegration prediction model via the initial ISQ values was processed. RESULTS: Initial ISQ values showed significant correlation with the BIC%. The bone volume % did not show any significant association with the ISQ values. CONCLUSION: In the limitation of this study, resonance frequency analysis is a useful clinical method to predict the BIC% values and examine the implant stability. |
format | Online Article Text |
id | pubmed-3141122 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | The Korean Academy of Prosthodontics |
record_format | MEDLINE/PubMed |
spelling | pubmed-31411222011-08-03 The relationship between initial implant stability quotient values and bone-to-implant contact ratio in the rabbit tibia Park, In-Phill Kim, Seong-Kyun Lee, Shin-Jae Lee, Joo-Hee J Adv Prosthodont Original Article PURPOSE: Implant stability quotient (ISQ) values have been supposed to predict implant stability. However, the relationship between ISQ values and bone-to-implant contact ratio (BIC%) which is one of the predictors of implant stability is still unclear. The aim of the present study was to evaluate initial ISQ values in relation to BIC% using rabbit model. MATERIALS AND METHODS: Four New Zealand white rabbits received a total of 16 implants in their tibia. Immediately after implant placement ISQ values were assessed. The measurements were repeated at the time of sacrifice of the rabbits after 4 weeks. Peri-implant bone regeneration was assessed histomorphometrically by measuring BIC% and bone volume to total volume values (bone volume %). The relationships between ISQ values and the histomorphometric output were assessed, and then, the osseointegration prediction model via the initial ISQ values was processed. RESULTS: Initial ISQ values showed significant correlation with the BIC%. The bone volume % did not show any significant association with the ISQ values. CONCLUSION: In the limitation of this study, resonance frequency analysis is a useful clinical method to predict the BIC% values and examine the implant stability. The Korean Academy of Prosthodontics 2011-06 2011-06-30 /pmc/articles/PMC3141122/ /pubmed/21814615 http://dx.doi.org/10.4047/jap.2011.3.2.76 Text en © 2011 The Korean Academy of Prosthodontics http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Park, In-Phill Kim, Seong-Kyun Lee, Shin-Jae Lee, Joo-Hee The relationship between initial implant stability quotient values and bone-to-implant contact ratio in the rabbit tibia |
title | The relationship between initial implant stability quotient values and bone-to-implant contact ratio in the rabbit tibia |
title_full | The relationship between initial implant stability quotient values and bone-to-implant contact ratio in the rabbit tibia |
title_fullStr | The relationship between initial implant stability quotient values and bone-to-implant contact ratio in the rabbit tibia |
title_full_unstemmed | The relationship between initial implant stability quotient values and bone-to-implant contact ratio in the rabbit tibia |
title_short | The relationship between initial implant stability quotient values and bone-to-implant contact ratio in the rabbit tibia |
title_sort | relationship between initial implant stability quotient values and bone-to-implant contact ratio in the rabbit tibia |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3141122/ https://www.ncbi.nlm.nih.gov/pubmed/21814615 http://dx.doi.org/10.4047/jap.2011.3.2.76 |
work_keys_str_mv | AT parkinphill therelationshipbetweeninitialimplantstabilityquotientvaluesandbonetoimplantcontactratiointherabbittibia AT kimseongkyun therelationshipbetweeninitialimplantstabilityquotientvaluesandbonetoimplantcontactratiointherabbittibia AT leeshinjae therelationshipbetweeninitialimplantstabilityquotientvaluesandbonetoimplantcontactratiointherabbittibia AT leejoohee therelationshipbetweeninitialimplantstabilityquotientvaluesandbonetoimplantcontactratiointherabbittibia AT parkinphill relationshipbetweeninitialimplantstabilityquotientvaluesandbonetoimplantcontactratiointherabbittibia AT kimseongkyun relationshipbetweeninitialimplantstabilityquotientvaluesandbonetoimplantcontactratiointherabbittibia AT leeshinjae relationshipbetweeninitialimplantstabilityquotientvaluesandbonetoimplantcontactratiointherabbittibia AT leejoohee relationshipbetweeninitialimplantstabilityquotientvaluesandbonetoimplantcontactratiointherabbittibia |