The relationship between initial implant stability quotient values and bone-to-implant contact ratio in the rabbit tibia

PURPOSE: Implant stability quotient (ISQ) values have been supposed to predict implant stability. However, the relationship between ISQ values and bone-to-implant contact ratio (BIC%) which is one of the predictors of implant stability is still unclear. The aim of the present study was to evaluate i...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, In-Phill, Kim, Seong-Kyun, Lee, Shin-Jae, Lee, Joo-Hee
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Prosthodontics 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3141122/
https://www.ncbi.nlm.nih.gov/pubmed/21814615
http://dx.doi.org/10.4047/jap.2011.3.2.76
_version_ 1782208629801222144
author Park, In-Phill
Kim, Seong-Kyun
Lee, Shin-Jae
Lee, Joo-Hee
author_facet Park, In-Phill
Kim, Seong-Kyun
Lee, Shin-Jae
Lee, Joo-Hee
author_sort Park, In-Phill
collection PubMed
description PURPOSE: Implant stability quotient (ISQ) values have been supposed to predict implant stability. However, the relationship between ISQ values and bone-to-implant contact ratio (BIC%) which is one of the predictors of implant stability is still unclear. The aim of the present study was to evaluate initial ISQ values in relation to BIC% using rabbit model. MATERIALS AND METHODS: Four New Zealand white rabbits received a total of 16 implants in their tibia. Immediately after implant placement ISQ values were assessed. The measurements were repeated at the time of sacrifice of the rabbits after 4 weeks. Peri-implant bone regeneration was assessed histomorphometrically by measuring BIC% and bone volume to total volume values (bone volume %). The relationships between ISQ values and the histomorphometric output were assessed, and then, the osseointegration prediction model via the initial ISQ values was processed. RESULTS: Initial ISQ values showed significant correlation with the BIC%. The bone volume % did not show any significant association with the ISQ values. CONCLUSION: In the limitation of this study, resonance frequency analysis is a useful clinical method to predict the BIC% values and examine the implant stability.
format Online
Article
Text
id pubmed-3141122
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher The Korean Academy of Prosthodontics
record_format MEDLINE/PubMed
spelling pubmed-31411222011-08-03 The relationship between initial implant stability quotient values and bone-to-implant contact ratio in the rabbit tibia Park, In-Phill Kim, Seong-Kyun Lee, Shin-Jae Lee, Joo-Hee J Adv Prosthodont Original Article PURPOSE: Implant stability quotient (ISQ) values have been supposed to predict implant stability. However, the relationship between ISQ values and bone-to-implant contact ratio (BIC%) which is one of the predictors of implant stability is still unclear. The aim of the present study was to evaluate initial ISQ values in relation to BIC% using rabbit model. MATERIALS AND METHODS: Four New Zealand white rabbits received a total of 16 implants in their tibia. Immediately after implant placement ISQ values were assessed. The measurements were repeated at the time of sacrifice of the rabbits after 4 weeks. Peri-implant bone regeneration was assessed histomorphometrically by measuring BIC% and bone volume to total volume values (bone volume %). The relationships between ISQ values and the histomorphometric output were assessed, and then, the osseointegration prediction model via the initial ISQ values was processed. RESULTS: Initial ISQ values showed significant correlation with the BIC%. The bone volume % did not show any significant association with the ISQ values. CONCLUSION: In the limitation of this study, resonance frequency analysis is a useful clinical method to predict the BIC% values and examine the implant stability. The Korean Academy of Prosthodontics 2011-06 2011-06-30 /pmc/articles/PMC3141122/ /pubmed/21814615 http://dx.doi.org/10.4047/jap.2011.3.2.76 Text en © 2011 The Korean Academy of Prosthodontics http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Park, In-Phill
Kim, Seong-Kyun
Lee, Shin-Jae
Lee, Joo-Hee
The relationship between initial implant stability quotient values and bone-to-implant contact ratio in the rabbit tibia
title The relationship between initial implant stability quotient values and bone-to-implant contact ratio in the rabbit tibia
title_full The relationship between initial implant stability quotient values and bone-to-implant contact ratio in the rabbit tibia
title_fullStr The relationship between initial implant stability quotient values and bone-to-implant contact ratio in the rabbit tibia
title_full_unstemmed The relationship between initial implant stability quotient values and bone-to-implant contact ratio in the rabbit tibia
title_short The relationship between initial implant stability quotient values and bone-to-implant contact ratio in the rabbit tibia
title_sort relationship between initial implant stability quotient values and bone-to-implant contact ratio in the rabbit tibia
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3141122/
https://www.ncbi.nlm.nih.gov/pubmed/21814615
http://dx.doi.org/10.4047/jap.2011.3.2.76
work_keys_str_mv AT parkinphill therelationshipbetweeninitialimplantstabilityquotientvaluesandbonetoimplantcontactratiointherabbittibia
AT kimseongkyun therelationshipbetweeninitialimplantstabilityquotientvaluesandbonetoimplantcontactratiointherabbittibia
AT leeshinjae therelationshipbetweeninitialimplantstabilityquotientvaluesandbonetoimplantcontactratiointherabbittibia
AT leejoohee therelationshipbetweeninitialimplantstabilityquotientvaluesandbonetoimplantcontactratiointherabbittibia
AT parkinphill relationshipbetweeninitialimplantstabilityquotientvaluesandbonetoimplantcontactratiointherabbittibia
AT kimseongkyun relationshipbetweeninitialimplantstabilityquotientvaluesandbonetoimplantcontactratiointherabbittibia
AT leeshinjae relationshipbetweeninitialimplantstabilityquotientvaluesandbonetoimplantcontactratiointherabbittibia
AT leejoohee relationshipbetweeninitialimplantstabilityquotientvaluesandbonetoimplantcontactratiointherabbittibia