Cargando…
Comparing ambient, air-convection, and fluid-convection heating techniques in treating hypothermic burn patients, a clinical RCT
BACKGROUND: Hypothermia in burns is common and increases morbidity and mortality. Several methods are available to reach and maintain normal core body temperature, but have not yet been evaluated in critical care for burned patients. Our unit's ordinary technique for controlling body temperatur...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3141603/ https://www.ncbi.nlm.nih.gov/pubmed/21736717 http://dx.doi.org/10.1186/1750-1164-5-4 |
_version_ | 1782208715768725504 |
---|---|
author | Kjellman, Britt-Marie Fredrikson, Mats Glad-Mattsson, Gunilla Sjöberg, Folke Huss, Fredrik RM |
author_facet | Kjellman, Britt-Marie Fredrikson, Mats Glad-Mattsson, Gunilla Sjöberg, Folke Huss, Fredrik RM |
author_sort | Kjellman, Britt-Marie |
collection | PubMed |
description | BACKGROUND: Hypothermia in burns is common and increases morbidity and mortality. Several methods are available to reach and maintain normal core body temperature, but have not yet been evaluated in critical care for burned patients. Our unit's ordinary technique for controlling body temperature (Bair Hugger(®)+ radiator ceiling + bed warmer + Hotline(®)) has many drawbacks e.g.; slow and the working environment is hampered. The aim of this study was to compare our ordinary heating technique with newly-developed methods: the Allon™2001 Thermowrap (a temperature regulating water-mattress), and Warmcloud (a temperature regulating air-mattress). METHODS: Ten consecutive burned patients (> 20% total burned surface area and a core temperature < 36.0°C) were included in this prospective, randomised, comparative study. Patients were randomly exposed to 3 heating methods. Each treatment/measuring-cycle lasted for 6 hours. Each heating method was assessed for 2 hours according to a randomised timetable. Core temperature was measured using an indwelling (bladder) thermistor. Paired t-tests were used to assess the significance of differences between the treatments within the patients. ANOVA was used to assess the differences in temperature from the first to the last measurement among all treatments. Three-way ANOVA with the Tukey HSD post hoc test and a repeated measures ANOVA was used in the same manner, but included information about patients and treatment/measuring-cycles to control for potential confounding. Data are presented as mean (SD) and (range). Probabilities of less than 0.05 were accepted as significant. RESULTS: The mean increase, 1.4 (SD 0.6°C; range 0.6-2.6°C) in core temperature/treatment/measuring-cycle highly significantly favoured the Allon™2001 Thermowrap in contrast to the conventional method 0.2 (0.6)°C (range -1.2 to 1.5°C) and the Warmcloud 0.3 (0.4)°C (range -0.4 to 0.9°C). The procedures for using the Allon™2001 Thermowrap were experienced to be more comfortable and straightforward than the conventional method or the Warmcloud. CONCLUSIONS: The Allon™2001 Thermowrap was more effective than the Warmcloud or the conventional method in controlling patients' temperatures. |
format | Online Article Text |
id | pubmed-3141603 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-31416032011-07-23 Comparing ambient, air-convection, and fluid-convection heating techniques in treating hypothermic burn patients, a clinical RCT Kjellman, Britt-Marie Fredrikson, Mats Glad-Mattsson, Gunilla Sjöberg, Folke Huss, Fredrik RM Ann Surg Innov Res Research Article BACKGROUND: Hypothermia in burns is common and increases morbidity and mortality. Several methods are available to reach and maintain normal core body temperature, but have not yet been evaluated in critical care for burned patients. Our unit's ordinary technique for controlling body temperature (Bair Hugger(®)+ radiator ceiling + bed warmer + Hotline(®)) has many drawbacks e.g.; slow and the working environment is hampered. The aim of this study was to compare our ordinary heating technique with newly-developed methods: the Allon™2001 Thermowrap (a temperature regulating water-mattress), and Warmcloud (a temperature regulating air-mattress). METHODS: Ten consecutive burned patients (> 20% total burned surface area and a core temperature < 36.0°C) were included in this prospective, randomised, comparative study. Patients were randomly exposed to 3 heating methods. Each treatment/measuring-cycle lasted for 6 hours. Each heating method was assessed for 2 hours according to a randomised timetable. Core temperature was measured using an indwelling (bladder) thermistor. Paired t-tests were used to assess the significance of differences between the treatments within the patients. ANOVA was used to assess the differences in temperature from the first to the last measurement among all treatments. Three-way ANOVA with the Tukey HSD post hoc test and a repeated measures ANOVA was used in the same manner, but included information about patients and treatment/measuring-cycles to control for potential confounding. Data are presented as mean (SD) and (range). Probabilities of less than 0.05 were accepted as significant. RESULTS: The mean increase, 1.4 (SD 0.6°C; range 0.6-2.6°C) in core temperature/treatment/measuring-cycle highly significantly favoured the Allon™2001 Thermowrap in contrast to the conventional method 0.2 (0.6)°C (range -1.2 to 1.5°C) and the Warmcloud 0.3 (0.4)°C (range -0.4 to 0.9°C). The procedures for using the Allon™2001 Thermowrap were experienced to be more comfortable and straightforward than the conventional method or the Warmcloud. CONCLUSIONS: The Allon™2001 Thermowrap was more effective than the Warmcloud or the conventional method in controlling patients' temperatures. BioMed Central 2011-07-07 /pmc/articles/PMC3141603/ /pubmed/21736717 http://dx.doi.org/10.1186/1750-1164-5-4 Text en Copyright ©2011 Kjellman et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Kjellman, Britt-Marie Fredrikson, Mats Glad-Mattsson, Gunilla Sjöberg, Folke Huss, Fredrik RM Comparing ambient, air-convection, and fluid-convection heating techniques in treating hypothermic burn patients, a clinical RCT |
title | Comparing ambient, air-convection, and fluid-convection heating techniques in treating hypothermic burn patients, a clinical RCT |
title_full | Comparing ambient, air-convection, and fluid-convection heating techniques in treating hypothermic burn patients, a clinical RCT |
title_fullStr | Comparing ambient, air-convection, and fluid-convection heating techniques in treating hypothermic burn patients, a clinical RCT |
title_full_unstemmed | Comparing ambient, air-convection, and fluid-convection heating techniques in treating hypothermic burn patients, a clinical RCT |
title_short | Comparing ambient, air-convection, and fluid-convection heating techniques in treating hypothermic burn patients, a clinical RCT |
title_sort | comparing ambient, air-convection, and fluid-convection heating techniques in treating hypothermic burn patients, a clinical rct |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3141603/ https://www.ncbi.nlm.nih.gov/pubmed/21736717 http://dx.doi.org/10.1186/1750-1164-5-4 |
work_keys_str_mv | AT kjellmanbrittmarie comparingambientairconvectionandfluidconvectionheatingtechniquesintreatinghypothermicburnpatientsaclinicalrct AT fredriksonmats comparingambientairconvectionandfluidconvectionheatingtechniquesintreatinghypothermicburnpatientsaclinicalrct AT gladmattssongunilla comparingambientairconvectionandfluidconvectionheatingtechniquesintreatinghypothermicburnpatientsaclinicalrct AT sjobergfolke comparingambientairconvectionandfluidconvectionheatingtechniquesintreatinghypothermicburnpatientsaclinicalrct AT hussfredrikrm comparingambientairconvectionandfluidconvectionheatingtechniquesintreatinghypothermicburnpatientsaclinicalrct |